Peripheral blood stem cells collection on spectra optia apheresis system using the continuous mononuclear cell collection protocol: A single center report of 39 procedures

被引:17
作者
Sanderson, F. [1 ]
Poullin, P. [1 ]
Smith, R. [2 ]
Nicolino-Brunet, C. [3 ]
Philip, P. [4 ]
Chaib, A. [5 ]
Costello, R. [6 ]
机构
[1] CHU La Conception, Serv Hemapherese Auto Transfus, 147 Blvd Baille, F-13005 Marseille, France
[2] Terumo BCT, Lakewood, CO USA
[3] CHU La Conception, Lab Hematol, Marseille, France
[4] Etab Francais Sang Alpes Mediterranee, St Laurent Du Var, France
[5] Serv Hematol Oncol, Aix En Provence, France
[6] CHU La Conception, Serv Hematol & Therapie Cellulaire, Marseille, France
关键词
peripheral blood stem-cell collection; apheresis; autologous peripheral blood stem-cell transplantation; optia CMNC; neutrophil recovery; STIMULATED DONORS; CMNC PROTOCOL; LEUKAPHERESIS; PROGENITOR; SEPARATOR; VALIDATION; EXPERIENCE; EFFICIENCY;
D O I
10.1002/jca.21485
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The aim of the study was to assess the performance of the new Continuous Mononuclear Cell Collection (CMNC) protocol on the Spectra Optia Apheresis System for collecting autologous Peripheral Blood Stem Cells (PBSC) in adult patients with respect to collection variables, CD34+ cells harvest prediction and engraftment data. In this retrospective study, 39 CMNC procedures on 23 mobilized patients with multiple myeloma and lymphoma were analyzed. CD34+ cells and blood cells yields, collection efficiencies (CE1 and CE2), cell losses were calculated. Engraftment data of 17 autologous transplantations were collected. Results: Apheresis duration was 239 min for a product volume of 220 mL. Cell product haematocrit, MNC and platelets counts were acceptable (respectively 2.4%, 65%, 834 x 109/L). Median platelet loss was 27.3%. Median CD34+ CE1 and CE2 were 64.6% and 48.5% respectively. We harvested 2.92 x 10(6)CD34+ cells/kg, with a CD34 dose >= 2 x 10(6)/kg for 67% of the procedures. Linear correlation between preapheresis CD34 count and the CP CD34 dose/kg allowed a prediction model with a decrease trend for high WBC precount. Procedures were well tolerated. For 17 autologous transplantations, median time to neutrophils and platelets reconstitutions were 12 and 13 days respectively. Conclusions: Spectra Optia CMNC protocol successfully collected CD34+ cells with yields permitting the harvest of sufficient enriched grafts for autologous transplantation. The CD34+ cell yield prediction was excellent. PBSC collection with CMNC protocol had advantages of high processing rate, low product volume, and acceptable contamination by platelets.
引用
收藏
页码:182 / 190
页数:9
相关论文
共 18 条
  • [1] Allogeneic donor peripheral blood "stem cell" apheresis: prospective comparison of two apheresis systems
    Brauninger, Susanne
    Bialleck, Heike
    Thorausch, Kristin
    Felt, Tom
    Seifried, Erhard
    Bonig, Halvard
    [J]. TRANSFUSION, 2012, 52 (05) : 1137 - 1145
  • [2] Hematopoietic progenitor cell large volume leukapheresis (LVL) on the Fenwal Amicus blood separator
    Burgstaler, EA
    Pineda, AA
    Winters, JL
    [J]. JOURNAL OF CLINICAL APHERESIS, 2004, 19 (02) : 103 - 111
  • [3] A prospective randomized trial of two popular mononuclear cell collection sets for autologous peripheral blood stem cell collection in multiple myeloma
    Cooling, Laura
    Hoffmann, Sandra
    Herrst, Michelle
    Muck, Charles
    Armelagos, Heidi
    Davenport, Robertson
    [J]. TRANSFUSION, 2010, 50 (01) : 100 - 119
  • [4] HPC-A Dose Prediction on the Optia® Cell Separator Based on a Benchmark CE2 Collection Efficiency: Promoting Clinical Efficiency, Minimizing Toxicity, and Allowing Quality Control
    Cousins, Antony F.
    Sinclair, Joy E.
    Alcorn, Michael J.
    Green, Rachel H. A.
    Douglas, Kenny W.
    [J]. JOURNAL OF CLINICAL APHERESIS, 2015, 30 (06) : 321 - 328
  • [5] Fischer JC, 2014, BONE MARROW TRANSPL, V49, pS238
  • [6] A single center comparison between three different apheresis systems for autologous and allogeneic stem cell collections
    Flommersfeld, Sabine
    Bakchoul, Tamam
    Bein, Gregor
    Wachtel, Almut
    Loechelt, Cordula
    Sachs, Ulrich J.
    [J]. TRANSFUSION AND APHERESIS SCIENCE, 2013, 49 (03) : 428 - 433
  • [7] Change in CD34+cell concentration during peripheral blood progenitor cell collection: effects on collection efficiency and efficacy
    Ford, CD
    Greenwood, J
    Strupp, A
    Lehman, CM
    [J]. TRANSFUSION, 2002, 42 (07) : 904 - 911
  • [8] Evaluation of the Spectra Optia Apheresis System for Mononuclear Cell (MNC) Collection in G-CSF Mobilized and Nonmobilized Healthy Donors: Results of a Multicenter Study
    Karafin, Matthew S.
    Graminske, Sharon
    Erickson, Paulette
    Walters, Mark C.
    Scott, Edward P.
    Carter, Scott
    Padmanabhan, Anand
    [J]. JOURNAL OF CLINICAL APHERESIS, 2014, 29 (05) : 273 - 280
  • [9] Lamb R, 2015, BONE MARROW TRANSPL, V50, pS349
  • [10] Evaluation of the Spectra Optia® Mononuclear Cell Collection Procedure in Multiple Myeloma Patients
    Long, Gwynn
    Waller, Edmund K.
    Gregurek, Steven
    Tricot, Guido
    Marschner, Susanne
    Bill, Jerry
    [J]. JOURNAL OF CLINICAL APHERESIS, 2015, 30 (01) : 1 - 7