Wide-field compensation of monochromatic eye aberrations:: expected performance and design trade-offs

被引:15
作者
Bará, S [1 ]
Navarro, R
机构
[1] Univ Santiago de Compostela, Area Opt, Dept Fis Aplicada, Galiza, Spain
[2] CSIC, Inst Opt Daza Valdes, Madrid, Spain
来源
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION | 2003年 / 20卷 / 01期
关键词
D O I
10.1364/JOSAA.20.000001
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The optical quality of the human eye varies across the visual field. Hence an exact compensation of the eye aberration for a given field point can give rise to a less-than-optimum compensation in neighboring field regions. We have studied some aspects of this problem and present here an approach to design wide-field (<10degrees) optically thin correcting elements, e.g., phase plates, deformable mirrors, and liquid-crystal displays. Their expected performance is assessed using actual eye aberration data. Particular attention is given to the design of elements providing a minimum averaged rms residual aberration and those providing a nearly uniform rms residual aberration across a given field. (C) 2003 Optical Society of America.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 31 条
[11]   Supernormal vision and high-resolution retinal imaging through adaptive optics [J].
Liang, JZ ;
Williams, DR ;
Miller, DT .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1997, 14 (11) :2884-2892
[12]   OBJECTIVE MEASUREMENT OF WAVE ABERRATIONS OF THE HUMAN EYE WITH THE USE OF A HARTMANN-SHACK WAVE-FRONT SENSOR [J].
LIANG, JZ ;
GRIMM, B ;
GOELZ, S ;
BILLE, JF .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1994, 11 (07) :1949-1957
[13]   Aberrations and retinal image quality of the normal human eye [J].
Liang, JZ ;
Williams, DR .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1997, 14 (11) :2873-2883
[14]   Wave-front correction and production of Zernike modes with a liquid-crystal spatial light modulator [J].
Love, GD .
APPLIED OPTICS, 1997, 36 (07) :1517-1524
[15]  
Malacara D., 1992, OPTICAL SHOP TESTING, P455
[16]  
MEDOFF BP, 1987, IMAGE RECOVERY THEOR, pCH9
[17]   Comparing laser ray tracing, the spatially resolved refractometer, and the Hartmann-Shack sensor to measure the ocular wave aberration [J].
Moreno-Barriuso, E ;
Marcos, S ;
Navarro, R ;
Burns, SA .
OPTOMETRY AND VISION SCIENCE, 2001, 78 (03) :152-156
[18]   Laser Ray Tracing versus Hartmann-Shack sensor for measuring optical aberrations in the human eye [J].
Moreno-Barriuso, E ;
Navarro, R .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2000, 17 (06) :974-985
[19]   Phase plates for wave-aberration compensation in the human eye [J].
Navarro, R ;
Moreno-Barriuso, E ;
Bará, S ;
Mancebo, T .
OPTICS LETTERS, 2000, 25 (04) :236-238
[20]   Monochromatic aberrations and point-spread functions of the human eye across the visual field [J].
Navarro, R ;
Moreno, E ;
Dorronsoro, C .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1998, 15 (09) :2522-2529