Fault diagnosis of T-type three-level inverter based on bridge voltages

被引:4
作者
Chen, Danjiang [1 ]
Liu, Yutian [1 ]
Zhang, Shaozhong [1 ]
机构
[1] Zhejiang Wanli Univ, Coll Informat & Intelligence Engn, Ningbo, Peoples R China
关键词
bridge voltage; fault diagnosis; fault signal; open-circuit fault; T-type three-level inverter;
D O I
10.24425/aee.2021.136053
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Multilevel inverters have been widely used in various occasions due to their advantages such as low harmonic content of the output waveform. However, because multilevel inverters use a large number of devices, the possibility of circuit failure is also higher than that of traditional inverters. A T-type three-level inverter is taken as the research object, and a diagnostic study is performed on the open-circuit fault of insulated gate bipolar transistor (IGBT) devices in the inverter. Firstly, the change of the current path in the inverter when an open-circuit fault of the device occurred, and the effect on the circuit switching states and the bridge voltages were analyzed. Then comprehensively considered the bridge voltages. and proposed a fault diagnosis method for a T-type three-level inverter based on specific fault diagnosis signals. Finally. the simulation verification was performed. The simulation results prove that the proposed method can accurately locate the open-circuit fault of the inverter device, and has the advantage of being easy to implement.
引用
收藏
页码:73 / 87
页数:15
相关论文
共 17 条
[1]   Method to diagnose open-circuit faults in active power switches and clamp-diodes of three-level neutral-point clamped inverters [J].
Abadi, Mohsen Bandar ;
Santos Mendes, Andre Manuel ;
Angelo Cruz, Sergio Manuel .
IET ELECTRIC POWER APPLICATIONS, 2016, 10 (07) :623-632
[2]  
[Anonymous], 2021, ENTERP INF SYST-UK, DOI DOI 10.1080/17517575.2019.1597387
[3]  
[Anonymous], MILITARY MED RES, DOI DOI 10.1186/S40594-020-00237-0
[4]   Open-circuit fault diagnosis method for the T-type inverter based on analysis of the switched bridge voltage [J].
Chen, Danjiang ;
Liu, Yutian ;
Zhang, Shaozhong .
IET POWER ELECTRONICS, 2019, 12 (02) :295-302
[5]   Diagnosis and Tolerant Strategy of an Open-Switch Fault for T-Type Three-Level Inverter Systems [J].
Choi, Ui-Min ;
Lee, Kyo-Beum ;
Blaabjerg, Frede .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2014, 50 (01) :495-508
[6]   A Fast On-Line Diagnostic Method for Open-Circuit Switch Faults in SiC-MOSFET-Based T-Type Multilevel Inverters [J].
He, Jiangbiao ;
Demerdash, Nabeel A. O. ;
Weise, Nathan ;
Katebi, Ramin .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2017, 53 (03) :2948-2958
[7]   A Reduced Component Count Five-Level Inverter Topology for High Reliability Electric Drives [J].
Karthik, A. ;
Loganathan, Umanand .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2020, 35 (01) :725-732
[8]   Analysis and Compensation of Inverter Nonlinearity for Three-Level T-Type Inverters [J].
Kim, Hyeon-Sik ;
Kwon, Yong-Cheol ;
Chee, Seung-Jun ;
Sul, Seung-Ki .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (06) :4970-4980
[9]   Structure and the space vector modulation for a medium-voltage power-electronic-transformer based on two seven-level cascade H-bridge inverters [J].
Lewicki, Arkadiusz ;
Morawiec, Marcin .
IET ELECTRIC POWER APPLICATIONS, 2019, 13 (10) :1514-1523
[10]   Simultaneous Common-Mode Resonance Circulating Current and Leakage Current Suppression for Transformerless Three-Level T-Type PV Inverter System [J].
Li, Xiaoyan ;
Xing, Xiangyang ;
Zhang, Chenghui ;
Chen, Alian ;
Qin, Changwei ;
Zhang, Guangxian .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2019, 66 (06) :4457-4467