Microscopic X-ray fluorescence analysis and related methods with laboratory and synchrotron radiation sources - Plenary lecture

被引:82
作者
Adams, F
Janssens, K
Snigirev, A
机构
[1] Univ Instelling Antwerp, Dept Chem, B-2610 Wilrijk, Belgium
[2] European Synchrotron Radiat Facil, F-38043 Grenoble, France
关键词
microprobe; X-ray fluorescence; synchrotron radiation; air particulates; archaeological analysis;
D O I
10.1039/a707100k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present status of microprobe versions of XRF analysis with tube excitation and with synchrotron radiation sources is reviewed with respect to analytical parameters such as lateral resolution and imaging capability, and achievable detection limits, precision and accuracy, The main characteristics of the method are contrasted with those of other microanalytical techniques, For laboratory source mu-XRF, results with a rotating anode tube equipped with capillary X-ray optics are discussed in terms of sensitivity and achievable lateral resolution. The possibilities of the new third generation synchrotron radiation storage rings, especially those of the European Synchrotron Radiation Facility (ESRF) and its X-ray micro-fluorescence, imaging and diffraction beamline (ID 22) are discussed and related to second generation storage rings. Some characteristic applications are given to illustrate the recent possibilities of the methodologies, in particular for the characterization of atmospheric particles, and in an analytical problem related to archaeology.
引用
收藏
页码:319 / 331
页数:13
相关论文
共 64 条
  • [11] ENGSTROM P, 1996, ESRF NEWSL, V26, P30
  • [12] SWITCHING ON A BRILLIANT LIGHT
    GLANZ, J
    [J]. SCIENCE, 1995, 267 (5206) : 1904 - 1906
  • [13] Gorgl R, 1997, X-RAY SPECTROM, V26, P189
  • [14] ULTRAHIGH-RESOLUTION X-RAY TOMOGRAPHY
    HADDAD, WS
    MCNULTY, I
    TREBES, JE
    ANDERSON, EH
    LEVESQUE, RA
    YANG, L
    [J]. SCIENCE, 1994, 266 (5188) : 1213 - 1215
  • [16] IIDA A, 1991, TRENDS ANAL CHEM, V10, P215
  • [17] Optimisation of total-reflection X-ray fluorescence for aerosol analysis
    Injuk, J
    VanGrieken, R
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1995, 50 (14) : 1787 - 1803
  • [18] CHEMICAL CHARACTERIZATION OF AIR PARTICULATE SAMPLES USING X-RAY ABSORPTION-SPECTROSCOPY
    JAKLEVIC, JM
    KIRBY, JA
    RAMPONI, AJ
    THOMPSON, AC
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1980, 14 (04) : 437 - 441
  • [19] SYNCHROTRON-RADIATION-INDUCED X-RAY-MICROANALYSIS
    JANSSENS, K
    VINCZE, L
    ADAMS, F
    JONES, KW
    [J]. ANALYTICA CHIMICA ACTA, 1993, 283 (01) : 98 - 110
  • [20] Accurate evaluation of mu-PIXE and mu-XRF spectral data through iterative least squares fitting
    Janssens, K
    Vekemans, B
    Adams, F
    vanEspen, P
    Mutsaers, P
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1996, 109 : 179 - 185