The present status of microprobe versions of XRF analysis with tube excitation and with synchrotron radiation sources is reviewed with respect to analytical parameters such as lateral resolution and imaging capability, and achievable detection limits, precision and accuracy, The main characteristics of the method are contrasted with those of other microanalytical techniques, For laboratory source mu-XRF, results with a rotating anode tube equipped with capillary X-ray optics are discussed in terms of sensitivity and achievable lateral resolution. The possibilities of the new third generation synchrotron radiation storage rings, especially those of the European Synchrotron Radiation Facility (ESRF) and its X-ray micro-fluorescence, imaging and diffraction beamline (ID 22) are discussed and related to second generation storage rings. Some characteristic applications are given to illustrate the recent possibilities of the methodologies, in particular for the characterization of atmospheric particles, and in an analytical problem related to archaeology.
引用
收藏
页码:319 / 331
页数:13
相关论文
共 64 条
  • [1] CHEMICAL CONTRAST IN X-RAY MICROSCOPY AND SPATIALLY RESOLVED XANES SPECTROSCOPY OF ORGANIC SPECIMENS
    ADE, H
    ZHANG, X
    CAMERON, S
    COSTELLO, C
    KIRZ, J
    WILLIAMS, S
    [J]. SCIENCE, 1992, 258 (5084) : 972 - 975
  • [2] [Anonymous], [No title captured]
  • [3] X-RAY APPLICATIONS WITH GLASS-CAPILLARY OPTICS
    BILDERBACK, DH
    THIEL, DJ
    PAHL, R
    BRISTER, KE
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 1994, 1 : 37 - 42
  • [4] BOEHME DR, 1987, ADV XRAY ANAL, V30, P39
  • [5] CHAPMAN KL, 1993, P 4I DENV C APPL XRA, P119
  • [6] Chen ZZ, 1996, MICROW OPT TECHN LET, V13, P259, DOI 10.1002/(SICI)1098-2760(19961205)13:5<259::AID-MOP5>3.0.CO
  • [7] 2-F
  • [8] OBSERVATION OF INTERFERENCE EFFECTS AT THE FOCUS OF AN X-RAY LENS
    DABAGOV, SB
    KUMAKHOV, MA
    NIKITINA, SV
    MURASHOVA, VA
    FEDORCHUK, RV
    YAKIMENKO, MN
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 1995, 2 : 132 - 135
  • [9] ELLEUME P, 1997, ESRF NEWSL, V28, P33
  • [10] Low-angle synchrotron radiation diffraction with glass-capillary optics
    Engstrom, P
    Riekel, C
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 1996, 3 : 97 - 100