Coronary artery wall imaging: Initial experience at 3 Tesla

被引:26
作者
Koktzoglou, I
Simonetti, O
Li, DB
机构
[1] Northwestern Univ, Dept Radiol, Chicago, IL 60611 USA
[2] Northwestern Univ, Dept Biomed Engn, Chicago, IL 60611 USA
[3] Siemens Med Solut, Chicago, IL USA
关键词
magnetic resonance imaging (MRI); high field imaging; vessel wall imaging; coronary artery; black blood;
D O I
10.1002/jmri.20232
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the feasibility of black-blood turbo spin-echo imaging of the left anterior descending coronary artery wall at 3 Tesla under free-breathing and breath-hold conditions. Materials and Methods: Proton density-weighted black-blood turbo spin-echo imaging of the left anterior descending coronary artery was performed on 15 volunteers on a 3 T whole body scanner with an eight channel phased array coil. Volunteers were imaged during free-breathing (with navigators, N = 5), or with breath-hold (N = 5), or both (N = 2). Imaging was not possible in three volunteers due to either gradient or radiofrequency (RF) coupling with the electrocardiogram (ECG). Images were analyzed to determine coronary artery wall thickness, wall area, lumen diameter, and lumen area. Signal-to-noise and contrast-to-noise ratios were calculated. Results: Coronary artery wall thickness, wall area, lumen diameter, and lumen area measurements were consistent with previous magnetic resonance (MR) measurements of the coronary wall at 1.5 Tesla. Conclusion: Coronary wall imaging using free-breathing and breath-hold two-dimensional black-blood TSE is feasible at 3 T. Further improvement in resolution and image quality is required to detect and characterize coronary plaque.
引用
收藏
页码:128 / 132
页数:5
相关论文
共 15 条
  • [1] The sensitivity of low flip angle RARE imaging
    Alsop, DC
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (02) : 176 - 184
  • [2] Botnar RM, 2000, CIRCULATION, V102, P2582
  • [3] Initial experiences with in vivo right coronary artery human MR vessel wall imaging at 3 tesla
    Botnar, RM
    Stuber, M
    Lamerichs, R
    Smink, J
    Fischer, SE
    Harvey, P
    Manning, WJ
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2003, 5 (04) : 589 - 594
  • [4] Relationship between motion of coronary arteries and diaphragm during free breathing: Lessons from real-time MR imaging
    Danias, PG
    Stuber, M
    Botnar, RM
    Kissinger, KV
    Edelman, RR
    Manning, WJ
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (04) : 1061 - 1065
  • [5] Fayad ZA, 2000, CIRCULATION, V102, P506
  • [6] Double inversion black-blood fast spin-echo imaging of the human heart: A comparison between 1.5T and 3.0T
    Greenman, RL
    Shirosky, JE
    Mulkern, RV
    Rofsky, NM
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (06) : 648 - 655
  • [7] Hennig J, 2000, MAGNET RESON MED, V44, P983, DOI 10.1002/1522-2594(200012)44:6<983::AID-MRM23>3.0.CO
  • [8] 2-8
  • [9] Luk-Pat GT, 1999, MAGNET RESON MED, V42, P762, DOI 10.1002/(SICI)1522-2594(199910)42:4<762::AID-MRM19>3.0.CO
  • [10] 2-M