X-ray CT high-density artefact suppression in the presence of bones

被引:65
作者
Wei, JK
Chen, LG
Sandison, GA
Liang, Y
Xu, LX
机构
[1] Sch Hlth Sci, W Lafayette, IN 47907 USA
[2] Pfizer Global Res & Dev, Bioimaging Ctr Emphasis, Ann Arbor, MI 48105 USA
[3] Indiana Univ, Sch Med, Dept Radiol, Indianapolis, IN 46202 USA
[4] Sch Mech Engn, W Lafayette, IN 47907 USA
关键词
D O I
10.1088/0031-9155/49/24/001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents a novel method of reducing x-ray CT high-density artefacts generated by metal objects when abundant bone structures are present in the region of interest. This method has an advantage over previously proposed methods since it heavily suppresses the metal artefacts without introducing extra bone artefacts. The method of suppression requires that bone pixels are isolated and segmented by thresholding. Then artificial CT numbers are assigned to the bone pixels so that their projection profiles are smooth and thus can be simulated by a polynomial interpolation. The projection profile of the metal object is then removed to fully suppress the artefacts. The resulting processed profile is fed to a reconstruction routine and the previously preserved bone pixels added back. The new method utilizes two important features of the CT image with metal artefacts: (a) metal and bone pixels are not severely affected by the high-density artefacts and (b) the high-density artefacts can be located in specific projection channels in the profile domain, although they are spread out in the image domain. This suppression method solves the problem of CT image artefacts arising from metal objects in the body. It has the potential to greatly improve diagnostic CT imaging in the presence of these objects and treatment planning that utilizes CT for patients with metal applicators (e.g., brachytherapy for cervix cancer and prostate cryotherapy).
引用
收藏
页码:5407 / 5418
页数:12
相关论文
共 12 条
[1]   Suppression of high-density artefacts in x-ray CT images using temporal digital subtraction with application to cryotherapy [J].
Baissalov, R ;
Sandison, GA ;
Donnelly, BJ ;
Saliken, JC ;
McKinnon, JG ;
Muldrew, K ;
Rewcastle, JC .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (05) :N53-N59
[2]   A novel method for reducing high attenuation object artifacts in CT reconstructions [J].
Chen, LG ;
Liang, Y ;
Sandison, GA ;
Rydberg, J .
MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 :841-850
[3]   REPROJECTION USING A PARALLEL BACKPROJECTOR [J].
CRAWFORD, CR .
MEDICAL PHYSICS, 1986, 13 (04) :480-483
[4]   An iterative maximum-likelihood polychromatic algorithm for CT [J].
De Man, B ;
Nuyts, J ;
Dupont, P ;
Marchal, G ;
Suetens, P .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (10) :999-1008
[5]   AN ALGORITHM FOR THE REDUCTION OF METAL CLIP ARTIFACTS IN CT RECONSTRUCTIONS [J].
GLOVER, GH ;
PELC, NJ .
MEDICAL PHYSICS, 1981, 8 (06) :799-807
[6]   CORRECTION FOR BEAM HARDENING IN COMPUTED-TOMOGRAPHY [J].
HERMAN, GT .
PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (01) :81-106
[7]   REDUCTION OF CT ARTIFACTS CAUSED BY METALLIC IMPLANTS [J].
KALENDER, WA ;
HEBEL, R ;
EBERSBERGER, J .
RADIOLOGY, 1987, 164 (02) :576-577
[8]   X-ray CT monitoring of iceball growth and thermal distribution during cryosurgery [J].
Sandison, GA ;
Loye, MP ;
Rewcastle, JC ;
Hahn, LJ ;
Saliken, JC ;
McKinnon, JG ;
Donnelly, BJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (11) :3309-3324
[9]  
Tuy HK., 1993, EUR RADIOL, V3, P129, DOI DOI 10.1007/BF00169785
[10]   Iterative deblurring for CT metal artifact reduction [J].
Wang, G ;
Snyder, DL ;
OSullivan, JA ;
Vannier, MW .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (05) :657-664