Effect of non-Newtonian property of blood on flow through a stenosed tube

被引:31
|
作者
Ishikawa, T [1 ]
Guimaraes, LFR [1 ]
Oshima, S [1 ]
Yamane, R [1 ]
机构
[1] Tokyo Inst Technol, Dept Engn Sci & Mech, Meguro Ku, Tokyo 152, Japan
关键词
fluid dynamics; bio-fluid dynamics; non-Newtonian fluid; stenosis; pulsatile flows; numerical analysis;
D O I
10.1016/S0169-5983(97)00041-5
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
It is well known that the fluid dynamics of arterial blood flow plays an important role in arterial diseases. Periodic blood flow through a stenosed tube was analyzed numerically. The bi-viscosity model is used as a constitutive equation for blood, and the flow is assumed to be periodic, incompressible and axisymmetric. Effects of pulsation and the rheological property of blood are considered. The flow pattern, separated region and the distributions of pressure and shear stress at the wall are obtained. The results show that the non-Newtonian property reduces the strength of the vortex downstream of stenosis and has considerable influence on the flow even at high Stokes and Reynolds numbers, provided that pulsatile flow has a stagnant period. (C) 1998 The Japan Society of Fluid Mechanics Incorporated and Elsevier Science B.V. All rights reserved.
引用
收藏
页码:251 / 264
页数:14
相关论文
共 50 条
  • [1] Physiological Non-Newtonian Blood Flow through Single Stenosed Artery
    Mamun, Khairuzzaman
    Rahman, Mohammad Matiur
    Akhter, Most. Nasrin
    Ali, Mohammad
    PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON MECHANICAL ENGINEERING (ICME 2015), 2016, 1754
  • [2] Unsteady response of non-Newtonian blood flow through a stenosed artery in magnetic field
    Ikbal, Md. A.
    Chakravarty, S.
    Wong, Kelvin K. L.
    Mazumdar, J.
    Mandal, P. K.
    JOURNAL OF COMPUTATIONAL AND APPLIED MATHEMATICS, 2009, 230 (01) : 243 - 259
  • [3] Role of slip velocity in blood flow through stenosed arteries: A non-Newtonian model
    Misra, J. C.
    Shit, G. C.
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2007, 7 (03) : 337 - 353
  • [4] Analysis of non-newtonian fluid flow in a stenosed artery
    Sapna, S.
    INTERNATIONAL JOURNAL OF PHYSICAL SCIENCES, 2009, 4 (11): : 663 - 671
  • [5] Numerical Study of the Significance of the Non-Newtonian Nature of Blood in Steady Flow Through a Stenosed Vessel
    Bodnar, Tomas
    Sequeira, Adelia
    ADVANCES IN MATHEMATICAL FLUID MECHANICS: DEDICATED TO GIOVANNI PAOLO GALDI ON THE OCCASION OF HIS 60TH BIRTHDAY, INTERNATIONAL CONFERENCE ON MATHEMATICAL FLUID MECHANICS, 2007, 2010, : 83 - +
  • [6] Computational Modeling of Non-Newtonian Blood Flow Through Stenosed Arteries in the Presence of Magnetic Field
    Alshare, Aiman
    Tashtoush, Bourhan
    El-Khalil, Hossam H.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2013, 135 (11):
  • [7] Mass transport in blood flow through a stenosed tube
    Ishikawa, T
    Oshima, S
    Yamane, R
    JSME INTERNATIONAL JOURNAL SERIES C-MECHANICAL SYSTEMS MACHINE ELEMENTS AND MANUFACTURING, 1999, 42 (03): : 680 - 688
  • [8] Effect of non-Newtonian behaviour on fluid structural interaction for flow through a model stenosed artery
    Haque, Md Rejaul
    Hossain, Md Emran
    Hasan, A. B. M. Toufique
    10TH INTERNATIONAL CONFERENCE ON MECHANICAL ENGINEERING (ICME 2013), 2014, 90 : 358 - 363
  • [9] THE ANALYSIS OF THE FLOW OF BLOOD IN A STENOSED ARTERY THROUGH SIMULATION: A COMPARISON AMONG VARIOUS NON-NEWTONIAN MODELS
    Narayan, S. shankar
    Bhattacharjee, Anuradha
    Saha, Sunanda
    Puneeth, Venkatesh
    Singhal, Abhinav
    Abdullaeva, Barno Sayfutdinovna
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2024, 24 (07)
  • [10] Study of Non-Newtonian Models for 1D Blood Flow Through a Stenosed Carotid Artery
    Udupa, Mahesh
    Saha, Sunanda
    MATHEMATICS AND COMPUTING, ICMC 2022, 2022, 415 : 523 - 539