Lithotripsy Performance of Specially Designed Laser Fiber Tips

被引:20
作者
Kronenberg, Peter [1 ]
Traxer, Olivier [2 ]
机构
[1] Hosp Prof Doutor Fernando Fonseca, Amadora, Portugal
[2] Univ Paris 06, Hop Tenon, Paris, France
关键词
calculi; lithotripsy; lasers; solid-state; surgical instruments; equipment reuse; YAG LASER; DEGRADATION; FRAGMENTATION; DIAMETERS; SETTINGS;
D O I
10.1016/j.juro.2015.10.135
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: We evaluated and compared a standard laser lithotripsy fiber to laser fibers claimed to have lithotripsy performance enhancing features. Materials and Methods: A special AccuMax (TM) 200 polished tip fiber and an AccuTrac (TM) ball-shaped tip fiber, each with an approximately 240 mm core, were compared to a standard 272 mm core fiber (Rocamed (TM)). The polished and ball-shaped tip fibers were used and reused without preparation. The standard fiber was stripped and cleaved according to manufacturer instructions after each experiment. An automated laser fragmentation testing system was used to perform multiple 30-second laser lithotripsy experiments. To mimic most typical lithotripsy conditions soft and hard stone materials were used with high frequency, low pulse energy (20 Hz and 0.5 J) or with low frequency, high pulse energy (5 Hz and 2.0 J) lithotripter settings. Ablation volumes and laser fiber tip photographs before and after lithotripsy were compared. Results: The standard and ball-shaped tip fibers did not differ in ablation volume (p = 0.72) but they ablated 174% and 188% more stone, respectively, than the polished tip fiber (p < 0.0001). The ball-shaped tip showed remarkable fiber tip degradation after short-term use at low frequency, high pulse energy settings. When high pulse energy settings were applied first even for short-term use, the ablation volume achieved by the polished and ball-shaped tip fibers at high frequency, low pulse energy settings decreased more than 20%. Conclusions: The standard laser fiber was as good as and sometimes better than the specially designed fibers. Rapid degradation of the specially designed laser fiber tips strongly limits their general usefulness but ball-shaped tip fibers may be useful in specific situations.
引用
收藏
页码:1606 / 1612
页数:7
相关论文
共 50 条
  • [31] Rugged hollow fiber for the infrared and its use in laser lithotripsy
    Iwai, K
    Shi, YW
    Matsuura, Y
    Miyagi, M
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS: DIAGNOSTICS AND TREATMENT, 2002, 4916 : 115 - 119
  • [32] Cavitation Bubble Dynamics during Thulium Fiber Laser Lithotripsy
    Hardy, Luke A.
    Kennedy, Joshua D.
    Wilson, Christopher R.
    Irby, Pierce B.
    Fried, Nathaniel M.
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS XII, 2016, 9689
  • [33] Impact of pulse duration on Ho:YAG laser lithotripsy: fragmentation and dusting performance
    Bader, Markus J.
    Pongratz, Thomas
    Khoder, Wael
    Stief, Christian G.
    Herrmann, Thomas
    Nagele, Udo
    Sroka, Ronald
    WORLD JOURNAL OF UROLOGY, 2015, 33 (04) : 471 - 477
  • [34] Thulium:YAG laser: a good compromise between holmium:YAG and thulium fiber laser for endoscopic lithotripsy? A narrative review
    Chicaud, Marie
    Corrales, Mariela
    Kutchukian, Stessy
    Solano, Catalina
    Candela, Luigi
    Doizi, Steeve
    Traxer, Olivier
    Panthier, Frederic
    WORLD JOURNAL OF UROLOGY, 2023, 41 (12) : 3437 - 3447
  • [35] Miniature Ureteroscope Tip Designs for use in Thulium Fiber Laser Lithotripsy
    Kennedy, Joshua D.
    Wilson, Christopher R.
    Irby, Pierce B.
    Fried, Nathaniel M.
    THERAPEUTICS AND DIAGNOSTICS IN UROLOGY: LASERS, ROBOTICS, MINIMALLY INVASIVE, AND ADVANCED BIOMEDICAL DEVICES, 2017, 10038
  • [36] Lasers for stone lithotripsy: advantages/disadvantages of each laser source
    Emiliani, Esteban
    Kanashiro, Andres
    Angerri, Oriol
    CURRENT OPINION IN UROLOGY, 2023, 33 (04) : 302 - 307
  • [37] Fiber Optic Suctioning of Urinary Stone Phantoms During Laser Lithotripsy
    Blackmon, Richard L.
    Case, Jason R.
    Trammell, Susan R.
    Irby, Pierce B.
    Fried, Nathaniel M.
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS IX, 2013, 8565
  • [38] Endoscopic lithotripsy with a SuperPulsed thulium-fiber laser for ureteral stones: A single-center experience
    Enikeev, Dmitry
    Grigoryan, Vagarshak
    Fokin, Igor
    Morozov, Andrey
    Taratkin, Mark
    Klimov, Roman
    Kozlov, Vasiliy
    Gabdullina, Svetlana
    Glybochko, Petr
    INTERNATIONAL JOURNAL OF UROLOGY, 2021, 28 (03) : 261 - 265
  • [39] Complex biliary stones: Treatment with a small choledochoscope and laser lithotripsy
    Harris, VJ
    Sherman, S
    Trerotola, SO
    Snidow, JJ
    Johnson, MS
    Lehman, GA
    RADIOLOGY, 1996, 199 (01) : 71 - 77
  • [40] Comparison of holmium:YAG and thulium fiber laser lithotripsy: ablation thresholds, ablation rates, and retropulsion effects
    Blackmon, Richard L.
    Irby, Pierce B.
    Fried, Nathaniel M.
    JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (07)