Lithotripsy Performance of Specially Designed Laser Fiber Tips

被引:20
|
作者
Kronenberg, Peter [1 ]
Traxer, Olivier [2 ]
机构
[1] Hosp Prof Doutor Fernando Fonseca, Amadora, Portugal
[2] Univ Paris 06, Hop Tenon, Paris, France
关键词
calculi; lithotripsy; lasers; solid-state; surgical instruments; equipment reuse; YAG LASER; DEGRADATION; FRAGMENTATION; DIAMETERS; SETTINGS;
D O I
10.1016/j.juro.2015.10.135
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: We evaluated and compared a standard laser lithotripsy fiber to laser fibers claimed to have lithotripsy performance enhancing features. Materials and Methods: A special AccuMax (TM) 200 polished tip fiber and an AccuTrac (TM) ball-shaped tip fiber, each with an approximately 240 mm core, were compared to a standard 272 mm core fiber (Rocamed (TM)). The polished and ball-shaped tip fibers were used and reused without preparation. The standard fiber was stripped and cleaved according to manufacturer instructions after each experiment. An automated laser fragmentation testing system was used to perform multiple 30-second laser lithotripsy experiments. To mimic most typical lithotripsy conditions soft and hard stone materials were used with high frequency, low pulse energy (20 Hz and 0.5 J) or with low frequency, high pulse energy (5 Hz and 2.0 J) lithotripter settings. Ablation volumes and laser fiber tip photographs before and after lithotripsy were compared. Results: The standard and ball-shaped tip fibers did not differ in ablation volume (p = 0.72) but they ablated 174% and 188% more stone, respectively, than the polished tip fiber (p < 0.0001). The ball-shaped tip showed remarkable fiber tip degradation after short-term use at low frequency, high pulse energy settings. When high pulse energy settings were applied first even for short-term use, the ablation volume achieved by the polished and ball-shaped tip fibers at high frequency, low pulse energy settings decreased more than 20%. Conclusions: The standard laser fiber was as good as and sometimes better than the specially designed fibers. Rapid degradation of the specially designed laser fiber tips strongly limits their general usefulness but ball-shaped tip fibers may be useful in specific situations.
引用
收藏
页码:1606 / 1612
页数:7
相关论文
共 50 条
  • [1] Hollow steel tips for reducing distal fiber burn-back during thulium fiber laser lithotripsy
    Hutchens, Thomas C.
    Blackmon, Richard L.
    Irby, Pierce B.
    Fried, Nathaniel M.
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (07)
  • [2] Detachable fiber optic tips for use in thulium fiber laser lithotripsy
    Hutchens, Thomas C.
    Blackmon, Richard L.
    Irby, Pierce B.
    Fried, Nathaniel M.
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (03)
  • [3] Thulium Fiber Laser Lithotripsy using Small Spherical Distal Fiber Tips
    Wilson, Christopher R.
    Hardy, Luke A.
    Kennedy, Joshua D.
    Irby, Pierce B.
    Fried, Nathaniel M.
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS XII, 2016, 9689
  • [4] Thulium Fiber Laser Lithotripsy using Small, Medium, and Large Muzzle Brake Fiber Optic Tips
    Gonzalez, David A.
    Fried, Nathaniel M.
    THERAPEUTICS AND DIAGNOSTICS IN UROLOGY 2019, 2019, 10852
  • [5] Comparison of Detachable and Tapered Fiber Optic Tips for use in Thulium Fiber Laser Lithotripsy
    Hutchens, Thomas C.
    Blackmon, Richard L.
    Irby, Pierce B.
    Fried, Nathaniel M.
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS IX, 2013, 8565
  • [6] Update on intracorporeal laser lithotripsy
    Papatsoris, A.
    Chrisofos, M.
    Skolarikos, A.
    Varkarakis, I.
    Mitsogiannis, I.
    Mygdalis, V.
    Dellis, A.
    Buchholz, N.
    Masood, J.
    MINERVA MEDICA, 2013, 104 (01) : 55 - 60
  • [7] Thulium Fiber Laser Lithotripsy
    Scott, Nicholas J.
    Cilip, Christopher M.
    Fried, Nathaniel M.
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS V, 2009, 7161
  • [8] Thulium fiber laser lithotripsy in an in vitro ureter model
    Hardy, Luke A.
    Wilson, Christopher R.
    Irby, Pierce B.
    Fried, Nathaniel M.
    JOURNAL OF BIOMEDICAL OPTICS, 2014, 19 (12)
  • [9] The effect of force on laser fiber burnback during lithotripsy
    Aryaei, Ashkan
    Chia, Ray
    Peng, Steven
    THERAPEUTICS AND DIAGNOSTICS IN UROLOGY 2018, 2018, 10468
  • [10] An Integrated Fiber and Stone Basket Device for use in Thulium Fiber Laser Lithotripsy
    Wilson, Christopher R.
    Hutchens, Thomas C.
    Hardy, Luke A.
    Irby, Pierce B.
    Fried, Nathaniel M.
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS X, 2014, 8926