Efficacy of the SEPARPROCATH® radiation drape to reduce radiation exposure during cardiac catheterization: A pilot comparative study

被引:5
|
作者
Patet, Camille [1 ]
Ryckx, Nick [2 ]
Arroyo, Diego [1 ]
Cook, Stephane [1 ]
Goy, Jean-Jacques [1 ,3 ]
机构
[1] Univ & Hosp Fribourg, Dept Cardiol, Fribourg, Switzerland
[2] Lausanne Univ Hosp, Dept Radiat Phys, Lausanne, Switzerland
[3] Hirslanden AG, Dept Cardiol, Clin Cecil, Lausanne, Switzerland
关键词
innovation; interventional cardiologist; percutaneous coronary intervention; radiation exposure; radiation protection; OPERATOR; INTERVENTIONS; PROTECTION; SAFETY; STAFF;
D O I
10.1002/ccd.28130
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Interventional cardiologists are exposed to radiation-induced diseases, partly due to patient's scatter radiation. Objectives We sought to compare the radiation exposure (RE) of the cardiac catheterization room staff using SEPARPROCATH (R), a novel radio-protective drape versus standard shielding equipment. Methods This was a two-step prospective, randomized pilot trial: first, in experimental conditions using a phantom model, and second, during cardiac catheterization. Primary end-point was operator RE corresponding to the ratio between operator cumulative dose (CD) and dose area product (DAP). Secondary end-points were nurse RE, operator and nurse CD, DAP, and fluoroscopy time. Results A total of 51 patients were included. SEPARPROCATH (R) was associated with a lower operator RE (0.07 [0-0.19] vs. 0.37 [0.23-0.81] mu Sv/Gy.cm(2) without SEPARPROCATH (R), p value <0.0001) and lower nurse RE (0 [0-0.05] vs. 0.13 [0.03-0.28] mu Sv/Gy.cm(2), p value <0.0001) corresponding to an RE relative risk reduction of 81% and 99%, respectively. Similar reductions were observed for operator and nurse CDs. No difference was found in DAP (19 [11-29] vs. 14 [10-32] Gy.cm(2) without SEPARPROCATH (R), p value 0.81). Conclusion SEPARPROCATH (R) offers significant additional radioprotection to the operator and nurse during cardiac catheterization without affecting patient safety.
引用
收藏
页码:387 / 391
页数:5
相关论文
共 50 条
  • [21] Determinants of operator and patient radiation exposure during cardiac catheterization: Insights from the RadiCure (RADIation reduction during cardiac catheterization using real-timE monitoring) trial
    Christopoulos, Georgios
    Papayannis, Aristotelis C.
    Alomar, Mohammed
    Christakopoulos, Georgios E.
    Kotsia, Anna
    Michael, Tesfaldet T.
    Rangan, Bavana V.
    Roesle, Michele
    Shorrock, Deborah
    Makke, Lorenza
    Maragkoudakis, Spyros
    Mohammad, Atif
    Sarode, Karan
    Chambers, Charles E.
    Banerjee, Subhash
    Brilakis, Emmanouil S.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2016, 88 (07) : 1046 - 1055
  • [22] Retrospective study of patients radiation dose during cardiac catheterization procedures
    Osei, Beverley
    Xu, Lu
    Johnston, Amanda
    Darko, Sara
    Darko, Johnson
    Osei, Ernest
    BRITISH JOURNAL OF RADIOLOGY, 2019, 92 (1099)
  • [23] Efficacy of Low-Dose Compared With Standard-Dose Radiation for Cardiac Catheterization and Intervention (KAR RAD Study)
    Kar, Subrata
    Teleb, Mohamed
    Albaghdadi, Aymen
    Ibrahim, Ahmed
    Mukherjee, Debabrata
    JOURNAL OF INVASIVE CARDIOLOGY, 2019, 31 (06) : 187 - 194
  • [24] Relationship of Beam Angulation and Radiation Exposure in the Cardiac Catheterization Laboratory
    Agarwal, Shikhar
    Parashar, Akhil
    Bajaj, Navkaranbir Singh
    Khan, Imran
    Ahmad, Imran
    Heupler, Fredrick A., Jr.
    Bunte, Matthew
    Modi, Dhruv K.
    Tuzcu, E. Murat
    Kapadia, Samir R.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (05) : 558 - 566
  • [25] Reduction in Primary Operator Radiation Dose Exposure During Coronary Angioplasty Using Radiation Absorbing Drape
    Sharma, Amit B.
    Agrawal, Richa
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (10)
  • [26] An In-depth Analysis of the Adverse Effects of Ionizing Radiation Exposure on Cardiac Catheterization Staffs
    Alvandi, Maryam
    Javid, Roozbeh Narimani
    Shaghaghi, Zahra
    Farzipour, Soghra
    Nosrati, Sahar
    CURRENT RADIOPHARMACEUTICALS, 2024, 17 (03) : 219 - 228
  • [27] Efficacy of RADPAD® protection drape in reducing radiation exposure to the primary operator during Transcatheter Aortic Valve Implantation (TAVI)
    Sharma, Divyesh
    Ramsewak, Adesh
    Manoharan, Ganesh
    Spence, Mark S.
    MINERVA CARDIOANGIOLOGICA, 2016, 64 (01): : 41 - 46
  • [28] Radiation exposure of the operator during cardiac catheter ablation procedures
    Pantos, I.
    Koukorava, C.
    Nirgianaki, E.
    Carinou, E.
    Tzanalaridou, E.
    Efstathopoulos, E. P.
    Katritsis, D. G.
    RADIATION PROTECTION DOSIMETRY, 2012, 150 (03) : 306 - 311
  • [29] Impact of X-Ray Protective Drapes on Operator and Patient Radiation Exposure During Cardiac Catheterization
    de Ceuninck, Michel
    Dujardin, Karl
    Vanhaverbeke, Maarten
    Muyldermans, Philip
    de Walle, Stefaan Van
    Pauwelyn, Maarten
    Bergez, Bernard
    Desimpel, Francine
    Vanderheeren, Philippe
    Dekerpel, Filip
    Kamoen, Victor
    Van Beveren, Jan
    Bruneel, Wim
    Van Coillie, Patrick
    Cokelaere, Benny
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2025, 105 (02) : 475 - 482
  • [30] Old Dogs Can Learn New Tricks: Reducing Radiation Exposure in the Cardiac Catheterization Laboratory
    Colello, Stephanie S.
    Fiorilli, Paul N.
    Hirshfeld Jr, John W.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2024, 17 (02)