Efficacy of the SEPARPROCATH® radiation drape to reduce radiation exposure during cardiac catheterization: A pilot comparative study

被引:5
|
作者
Patet, Camille [1 ]
Ryckx, Nick [2 ]
Arroyo, Diego [1 ]
Cook, Stephane [1 ]
Goy, Jean-Jacques [1 ,3 ]
机构
[1] Univ & Hosp Fribourg, Dept Cardiol, Fribourg, Switzerland
[2] Lausanne Univ Hosp, Dept Radiat Phys, Lausanne, Switzerland
[3] Hirslanden AG, Dept Cardiol, Clin Cecil, Lausanne, Switzerland
关键词
innovation; interventional cardiologist; percutaneous coronary intervention; radiation exposure; radiation protection; OPERATOR; INTERVENTIONS; PROTECTION; SAFETY; STAFF;
D O I
10.1002/ccd.28130
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Interventional cardiologists are exposed to radiation-induced diseases, partly due to patient's scatter radiation. Objectives We sought to compare the radiation exposure (RE) of the cardiac catheterization room staff using SEPARPROCATH (R), a novel radio-protective drape versus standard shielding equipment. Methods This was a two-step prospective, randomized pilot trial: first, in experimental conditions using a phantom model, and second, during cardiac catheterization. Primary end-point was operator RE corresponding to the ratio between operator cumulative dose (CD) and dose area product (DAP). Secondary end-points were nurse RE, operator and nurse CD, DAP, and fluoroscopy time. Results A total of 51 patients were included. SEPARPROCATH (R) was associated with a lower operator RE (0.07 [0-0.19] vs. 0.37 [0.23-0.81] mu Sv/Gy.cm(2) without SEPARPROCATH (R), p value <0.0001) and lower nurse RE (0 [0-0.05] vs. 0.13 [0.03-0.28] mu Sv/Gy.cm(2), p value <0.0001) corresponding to an RE relative risk reduction of 81% and 99%, respectively. Similar reductions were observed for operator and nurse CDs. No difference was found in DAP (19 [11-29] vs. 14 [10-32] Gy.cm(2) without SEPARPROCATH (R), p value 0.81). Conclusion SEPARPROCATH (R) offers significant additional radioprotection to the operator and nurse during cardiac catheterization without affecting patient safety.
引用
收藏
页码:387 / 391
页数:5
相关论文
共 50 条
  • [1] Efficacy of RADPAD protection drape in reducing radiation exposure in the catheterization laboratory-First Indian study
    Shah, Pujan
    Khanna, Roopali
    Kapoor, Aditya
    Goel, Pravin K.
    INDIAN HEART JOURNAL, 2018, 70 : S265 - S268
  • [2] Efficacy of the RADPAD Protection Drape in Reducing Operators' Radiation Exposure in the Catheterization Laboratory: A Sham-Controlled Randomized Trial
    Vlastra, Wieneke
    Delewi, Ronak
    Sjauw, Krischan D.
    Beijk, Marcel A.
    Claessen, Bimmer E.
    Streekstra, Geert J.
    Bekker, Robbert J.
    van Hattum, Juliette C.
    Wykrzykowska, Joanna J.
    Vis, Marije M.
    Koch, Karel T.
    de Winter, Robbert J.
    Piek, Jan J.
    Henriques, Jose P. S.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (11)
  • [3] Resetting the Bar to Reduce Radiation Exposure During Ablation of Cardiac Arrhythmias
    Lindsay, Bruce D.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2018, 11 (03)
  • [4] Effective Reduction of Radiation Exposure during Cardiac Catheterization
    Gutierrez-Barrios, Alejandro
    Camacho-Galan, Hugo
    Medina-Camacho, Francisco
    Canadas-Pruano, Dolores
    Jimenez-Moreno, Antonio
    Calle-Perez, German
    Vazquez-Garcia, Rafael
    TEXAS HEART INSTITUTE JOURNAL, 2019, 46 (03): : 167 - 171
  • [5] Safety and effectiveness of strategies to reduce radiation exposure to proceduralists performing cardiac catheterization procedures: a systematic review
    Fernandez, Ritin
    Ellwood, Laura
    Barrett, David
    Weaver, James
    JBI EVIDENCE SYNTHESIS, 2021, 19 (01) : 4 - 33
  • [6] Important Strategies to Reduce Occupational Radiation Exposure in the Cardiac Catheterization Laboratory No Lower Limit
    Hirshfeld, John W.
    Fiorilli, Paul N.
    Silvestry, Frank E.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 1255 - 1258
  • [7] Reduction in operator radiation exposure during transradial catheterization and intervention using a simple lead drape
    Iqtidar, Ali F.
    Jeon, Cathy
    Rothman, Richard
    Snead, Randall
    Pyne, Christopher T.
    AMERICAN HEART JOURNAL, 2013, 165 (03) : 293 - 298
  • [8] Radiation exposure during cardiac catheterization: Implications for the transradial approach
    Komocsi, A.
    Konyi, A.
    Kovacs, E.
    Ungi, I.
    INTERVENTIONAL MEDICINE AND APPLIED SCIENCE, 2010, 2 (03) : 105 - 109
  • [9] Reduction in Radiation Exposure Rate During Transradial Catheterization and Intervention Using a Simple Lead Drape
    Iqtidar, Ali F.
    Snead, Randall
    Rothman, Richard
    Jeon, Cathy
    Dwyer, Kevin
    Pyne, Christopher
    CIRCULATION, 2011, 124 (21)
  • [10] Operators' radiation exposure reduction during cardiac catheterization using a removable shield
    Arrivi, Alessio
    Pucci, G.
    Vaudo, G.
    Bier, N.
    Bock, C.
    Casavecchia, M.
    Bazzucchi, M.
    Dominici, M.
    CARDIOVASCULAR INTERVENTION AND THERAPEUTICS, 2020, 35 (04) : 379 - 384