Effects of Detection Wavelengths on Soot Volume Fraction Measurements Using the Auto-Compensating LII Technique

被引:3
作者
Liu, F. [1 ]
Smallwood, G. J. [1 ]
机构
[1] CNR, Metrol Res Ctr, Ottawa, ON K1A 0R6, Canada
关键词
Soot; optical diagnostics; auto-compensating LII; detection wavelengths; LASER-INDUCED INCANDESCENCE; PARTICLE;
D O I
10.1080/00102202.2019.1678837
中图分类号
O414.1 [热力学];
学科分类号
摘要
Soot particles in the detection volume in general have different temperatures due to non-uniform laser fluence and particle size distribution. The thermal radiation intensity displays different temperature dependence at different wavelengths. The effective soot temperature inferred from the ratio of laser-induced incandescence (LII) signals in the auto-compensating LII (AC-LII) technique is dependent on the detection wavelengths and affects the measured soot volume fraction. This paper numerically investigates the effects of detection wavelengths on the inferred soot effective temperature and volume fraction under conditions relevant to laminar diffusion flames at atmospheric pressure and for three representative laser fluence distributions. Numerical calculations were conducted using an LII model for a laser pulse of 5.8 ns FWHM and 1064?nm and assuming a lognormal primary particle size distribution and neglecting the aggregation effect. LII signals were modeled at four wavelength bands centered at 420, 560, 680, and 790?nm and the effective soot temperature was derived over three pairs of LII signals, namely [420, 560?nm], [560, 680?nm], and [680, 790?nm]. The two shortest and two longest detection wavelengths respectively result in the highest and lowest effective soot temperature when the laser fluence is non-uniform. The inferred soot volume fraction displays the opposite trend as the effective soot temperature. The effective soot temperature is biased toward the highest values and AC-LII always underestimates the soot volume fraction. The detection wavelengths should be carefully selected to minimize the impact of non-uniform laser fluence and at the same time to maximize the accuracy of effective soot temperature.
引用
收藏
页码:144 / 158
页数:15
相关论文
共 17 条
[1]   Influence of spatial laser energy distribution on evaluated soot particle sizes using two-colour laser-induced incandescence in a flat premixed ethylene/air flame [J].
Bladh, H. ;
Johnsson, J. ;
Bengtsson, P. -E. .
APPLIED PHYSICS B-LASERS AND OPTICS, 2009, 96 (04) :645-656
[2]   Study of the formation of soot and its precursors in flames using optical diagnostics [J].
Desgroux, Pascale ;
Mercier, Xavier ;
Thomson, Kevin A. .
PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2013, 34 :1713-1738
[3]   THE EFFECT OF SOOT ON PYROMETRIC MEASUREMENTS OF COAL PARTICLE TEMPERATURE [J].
GROSSHANDLER, WL .
COMBUSTION AND FLAME, 1984, 55 (01) :59-71
[4]   Heat conduction from a spherical nano-particle: status of modeling heat conduction in laser-induced incandescence [J].
Liu, F. ;
Daun, K. J. ;
Snelling, D. R. ;
Smallwood, G. J. .
APPLIED PHYSICS B-LASERS AND OPTICS, 2006, 83 (03) :355-382
[5]   Sensitivity and relative error analyses of soot temperature and volume fraction determined by two-color LII [J].
Liu, F. ;
Snelling, D. R. ;
Thomson, K. A. ;
Smallwood, G. J. .
APPLIED PHYSICS B-LASERS AND OPTICS, 2009, 96 (04) :623-636
[6]   Effects of laser fluence non-uniformity on ambient-temperature soot measurements using the auto-compensating laser-induced incandescence technique [J].
Liu, Fengshan ;
Rogak, Steven ;
Snelling, David R. ;
Saffaripour, Meghdad ;
Thomson, Kevin A. ;
Smallwood, Gregory J. .
APPLIED PHYSICS B-LASERS AND OPTICS, 2016, 122 (11)
[7]   Effects of primary soot particle size distribution on the temperature of soot particles heated by a nanosecond pulsed laser in an atmospheric laminar diffusion flame [J].
Liu, FS ;
Stagg, BJ ;
Snelling, DR ;
Smallwood, GJ .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2006, 49 (3-4) :777-788
[8]  
Matsui Y., 1980, 800970 SAE, P123, DOI [10.1111/j.1753-4887.1980.tb05865.x, DOI 10.1111/J.1753-4887.1980.TB05865.X]
[9]   Probing soot formation, chemical and physical evolution, and oxidation: A review of in situ diagnostic techniques and needs [J].
Michelsen, H. A. .
PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2017, 36 (01) :717-735
[10]   Laser-induced incandescence: Particulate diagnostics for combustion, atmospheric, and industrial applications [J].
Michelsen, H. A. ;
Schulz, C. ;
Smallwood, G. J. ;
Will, S. .
PROGRESS IN ENERGY AND COMBUSTION SCIENCE, 2015, 51 :2-48