Efficiency of Recycling Double-Pass V-Corrugated Solar Air Collectors

被引:10
|
作者
Ho, Chii-Dong [1 ]
Hsiao, Ching-Fang [1 ]
Chang, Hsuan [1 ]
Tien, Yi-En [1 ]
Hong, Zih-Syuan [1 ]
机构
[1] Tamkang Univ, Energy & Optoelect Mat Res Ctr, Dept Chem & Mat Engn, New Taipei 251, Taiwan
来源
ENERGIES | 2017年 / 10卷 / 07期
关键词
solar air heater; V-corrugated absorber; recycle effect; heat-transfer efficiency; double-pass operation; PERFORMANCE EVALUATION; THERMAL PERFORMANCE; VORTEX GENERATORS; EXTERNAL RECYCLE; HEATER CHANNEL; IMPROVEMENT; ENERGY;
D O I
10.3390/en10070875
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The influence of recycling on double-pass solar air collectors with welding of the V-corrugated absorber has been studied experimentally and theoretically. Welding the V-corrugated absorber and the recycle-effect concept to the solar air collector was proposed to strengthen the convective heat-transfer coefficient due to turbulence promotion. Both the recycle effect and the V-corrugated absorber can effectively enhance the heat transfer efficiency compared to various designs such as single-pass, flat-plate double-pass, and double-pass wire mesh packed devices. Recycling operations and welding the V-corrugated absorber could enhance the collector efficiency by increasing the recycle ratio, incident solar radiations, and air mass flow rates. The most efficient and economical operating conditions were found at R approximate to 0.5, with relatively small hydraulic dissipated energy compensation. It was found that the turbulence intensity increase from welding the V-corrugated absorber into the solar air collector channel could compensate for the power consumption increase, when considering economic feasibility.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Recycle Effect on Device Performance of Wire Mesh Packed Double-Pass Solar Air Heaters
    Ho, Chii-Dong
    Lin, Chun-Sheng
    Yang, Tz-Jin
    Chao, Chun-Chieh
    ENERGIES, 2014, 7 (11): : 7568 - 7585
  • [32] Experimental assessment of double-pass solar air heater by incorporating perforated baffles and solar water heating system
    Tandel, Hiren U.
    Modi, Kalpesh, V
    RENEWABLE ENERGY, 2022, 183 : 385 - 405
  • [33] Performance analysis of a double-pass solar air heater system with asymmetric channel flow passages
    Raj, A. K.
    Kunal, G.
    Srinivas, M.
    Jayaraj, S.
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2019, 136 (01) : 21 - 38
  • [34] Collector efficiency of upward-type double-pass solar air heaters with fins attached
    Ho, Chii-Dong
    Yeh, Ho-Ming
    Chen, Tsung-Ching
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2011, 38 (01) : 49 - 56
  • [35] Performance improvement of double-pass solar air heater - A state of art of review
    Alam, Tabish
    Kim, Man-Hoe
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 79 : 779 - 793
  • [36] Some Design Aspects of the Assisted Solar Drying System with Double-Pass Finned Solar Collectors
    Supranto
    Ruslan, Mohammad Hafidz
    Yahya, Muhamad
    Sulaiman, Mohd Yusof
    Al Ghoul, Moiamad
    Zaharim, Azami
    Sopian, K.
    ENERGY PROBLEMS AND ENVIRONMENTAL ENGINEERING, 2009, : 326 - +
  • [37] Experimental Investigation of the Performance of a Double-Pass Unglazed Transpired Solar Air Heater
    Rabha, D. K.
    Pathak, D.
    Baruah, R.
    Kalita, T.
    Sharma, A.
    ADVANCES IN FLUID AND THERMAL ENGINEERING, 2019, : 571 - 584
  • [38] Performance assessment of double-pass parallel flow solar air heater with perforated multi-V ribs roughness - Part B
    Singh, Varun Pratap
    Jain, Siddharth
    Gupta, Jml
    EXPERIMENTAL HEAT TRANSFER, 2022, 35 (07) : 1059 - 1076
  • [39] Mathematical modeling and performance evaluations of a wood drying process using photovoltaic thermal and double-pass solar air collectors
    Chtioui, Salwa
    Khouya, Ahmed
    APPLIED THERMAL ENGINEERING, 2024, 255
  • [40] Collector Efficiency in Downward-Type Double-Pass Solar Air Heaters with Attached Fins and Operated by External Recycle
    Yeh, Ho-Ming
    Ho, Chii-Dong
    ENERGIES, 2012, 5 (08) : 2692 - 2707