Highly sensitive quantitation of pesticides in fruit juice samples by modeling four-way data gathered with high-performance liquid chromatography with fluorescence excitation-emission detection

被引:31
作者
Montemurro, Milagros [1 ]
Pinto, Licarion [2 ]
Veras, Germano [3 ]
Gomes, Adriano de Araujo [2 ]
Culzoni, Maria J. [1 ]
Ugulino de Araujo, Mario C. [2 ]
Goicoechea, Hector C. [1 ]
机构
[1] Univ Nacl Litoral, Lab Desarrollo Analit & Quimiometria LADAQ, Catedra Quim Analit 1, Fac Bioquim & Ciencias Biol, Ciudad Univ, RA-3000 Santa Fe, Argentina
[2] Univ Fed Paraiba, Lab Automacao & Instrumentacao Quim Analit & Quim, CCEN, Dept Quim, Caixa Postal 5093, BR-58051900 Joao Pessoa, Paraiba, Brazil
[3] Univ Estadual Paraiba, Ctr Ciencias & Tecnol, Dept Quim, BR-58429500 Campina Grande, PB, Brazil
关键词
Liquid chromatography; Four-way data array; Pesticides; Fruit juice; Multi-way calibration; PARTIAL LEAST-SQUARES; DIODE-ARRAY DETECTION; FLUOROMETRIC DETECTION; CARBAMATE PESTICIDES; MARKER PTERIDINES; 2ND-ORDER DATA; WATER SAMPLES; CALIBRATION; HPLC; DECOMPOSITION;
D O I
10.1016/j.talanta.2016.03.078
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A study regarding the acquisition and analytical utilization of four-way data acquired by monitoring excitation-emission fluorescence matrices at different elution time points in a fast HPLC procedure is presented. The data were modeled with three well-known algorithms: PARAFAC, U-PLS/RTL and MCR-ALS, the latter conveniently adapted to model third-order data. The second-order advantage was exploited when analyzing samples containing uncalibrated components. The best results were furnished with the algorithm U-PLS/RTL. This fact is indicative of both no peak time shifts occurrence among samples and high colinearity among spectra. Besides, this latent-variable structured algorithm is capable of better handle the need of achieving high sensitivity for the analysis of one of the analytes. In addition, a significant enhancement in both predictions and analytical figures of merit was observed for carbendazim, thiabendazole, fuberidazole, carbofuran, carbaryl and 1-naphtol, when going from second- to third-order data. LODs obtained were ranged between 0.02 and 2.4 mu g L-1. (c) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:208 / 218
页数:11
相关论文
共 47 条
[1]   Analytical Figures of Merit for Partial Least-Squares Coupled to Residual Multilinearization [J].
Allegrini, Franco ;
Olivieri, Alejandro C. .
ANALYTICAL CHEMISTRY, 2012, 84 (24) :10823-10830
[2]   Practical aspects of PARAFAC modeling of fluorescence excitation-emission data [J].
Andersen, CM ;
Bro, R .
JOURNAL OF CHEMOMETRICS, 2003, 17 (04) :200-215
[3]  
[Anonymous], 1987, J. Chemometrics, DOI [10.1002/cem.1180010107, DOI 10.1002/CEM.1180010107]
[4]   Trilinear least-squares and unfolded-PLS coupled to residual trilinearization:: New chemometric tools for the analysis of four-way instrumental data [J].
Arancibia, JA ;
Olivieri, AC ;
Gil, DB ;
Mansilla, AE ;
Durán-Merás, B ;
de la Peña, AM .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2006, 80 (01) :77-86
[5]   Ionic liquid-dispersive liquid-liquid microextraction for the simultaneous determination of pesticides and metabolites in soils using high-performance liquid chromatography and fluorescence detection [J].
Asensio-Ramos, Maria ;
Hernandez-Borges, Javier ;
Borges-Miguel, Teresa M. ;
Angel Rodriguez-Delgado, Miguel .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (30) :4808-4816
[6]   Chemometric resolution and quantification of four-way data arising from comprehensive 2D-LC-DAD analysis of human urine [J].
Bailey, Hope P. ;
Rutan, Sarah C. .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2011, 106 (01) :131-141
[7]   Sensitivity Equation for Quantitative Analysis with Multivariate Curve Resolution-Alternating Least-Squares: Theoretical and Experimental Approach [J].
Bauza, Maria C. ;
Ibanez, Gabriela A. ;
Tauler, Roma ;
Olivieri, Alejandro C. .
ANALYTICAL CHEMISTRY, 2012, 84 (20) :8697-8706
[8]   Analysis of three- and four-way data using multivariate curve resolution-alternating least squares with global multi-way kinetic fitting [J].
Bezemer, E ;
Rutan, SC .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2006, 81 (01) :82-93
[9]   Determination of five pesticides in juice, fruit and vegetable samples by means of liquid chromatography combined with multivariate curve resolution [J].
Boeris, Valeria ;
Arancibia, Juan A. ;
Olivieri, Alejandro C. .
ANALYTICA CHIMICA ACTA, 2014, 814 :23-30
[10]   Novel augmented parallel factor model for four-way calibration of high-performance liquid chromatography-fluorescence excitation-emission data [J].
Bortolato, Santiago A. ;
Lozano, Valeria A. ;
Munoz de la Pena, Arsenio ;
Olivieri, Alejandro C. .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2015, 141 :1-11