Reliability and Validity of Mini-Balance Evaluation System Test in Type 2 Diabetic Patients with Peripheral Neuropathy

被引:6
|
作者
Phyu, Sitt Nyein [1 ,2 ]
Peungsuwan, Punnee [2 ,3 ]
Puntumetakul, Rungthip [2 ,3 ]
Chatchawan, Uraiwan [2 ,3 ]
机构
[1] Khon Kean Univ, Fac Grad Sch, Khon Kaen 40002, Thailand
[2] Khon Kean Univ, Res Ctr Back Neck Other Joint Pain & Human Perfor, Khon Kaen 40002, Thailand
[3] Khon Kaen Univ, Fac Associated Med Sci, Sch Phys Therapy, Khon Kaen 40002, Thailand
关键词
balance; diabetic peripheral neuropathy; Mini-BESTest; BESTEST; PEOPLE; INDIVIDUALS; ABILITY; FALLS; RISK;
D O I
10.3390/ijerph19116944
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Type 2 diabetic peripheral neuropathy is known to cause balance limitations in static, dynamic, and functional activity. The Mini-BESTest, a shortened version of BESTest, was evolved to identify balance disorders within a short duration. No prior studies have yet been conducted to assess the usefulness of Mini-BESTest in the diagnosis of type 2 diabetic peripheral neuropathy. The current study aimed to examine the reliability and discriminant validity by comparing the Mini-BESTest scores between type 2 diabetic patients with peripheral neuropathy, divided into two 2 groups based on reporting scores of <4 and >= 4 in the MNSI questionnaire, respectively. Therefore, a cross-sectional study design was conducted including 44 type 2 diabetic patients (4 males and 40 females; aged 56.61 +/- 7.7 years old). Diabetic peripheral neuropathy was diagnosed by physical assessment using the Michigan Neuropathy Screening Instrument (MNSI). Inter-rater (two physiotherapists) and Intra-rater (7-10 days) reliability of the Mini-BESTest were explored with intraclass correlation coefficients (ICC2,1) and (ICC3,1). The Mini-BESTest presented an excellent inter-rater reliability (ICC2,1= 0.95, 95% CI = 0.91-0.97, SEM = 0.61) and an excellent intra-rater reliability (ICC3,1 = 0.93, 95% CI = 0.87-0.96, SEM = 0.66), with confirmation by a good agreement presented by the Bland-Altman plots. The internal consistency measured with the overall Cronbach's alpha showed an acceptable agreement (0.73). The MDC was 2.16. In addition, the Mini-BESTest scores in the type 2 diabetic neuropathy patients reporting MNSI questionnaire scores <4 was found to be significantly higher when compared with those reporting scores >= 4. The Mini-BESTest can be used as a highly reliable and valid clinical application in the population with type 2 diabetic peripheral neuropathy.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Responsiveness of the Mini-Balance Evaluation System Test in Type 2 Diabetic Patients with Peripheral Neuropathy
    Phyu, Sitt Nyein
    Wanpen, Sawitri
    Chatchawan, Uraiwan
    JOURNAL OF MULTIDISCIPLINARY HEALTHCARE, 2022, 15 : 3015 - 3028
  • [2] Reliability and Validity of the Persian Version of the Mini-Balance Evaluation Systems Test in Patients with Stroke
    Naghdi, Soofia
    Ansari, Noureddin Nakhostin
    Forogh, Bijan
    Khalifeloo, Maedeh
    Honarpisheh, Roshanak
    Nakhostin-Ansari, Amin
    NEUROLOGY AND THERAPY, 2020, 9 (02) : 567 - 574
  • [3] Reliability and Validity of the Persian Version of the Mini-Balance Evaluation Systems Test in Patients with Stroke
    Soofia Naghdi
    Noureddin Nakhostin Ansari
    Bijan Forogh
    Maedeh Khalifeloo
    Roshanak Honarpisheh
    Amin Nakhostin-Ansari
    Neurology and Therapy, 2020, 9 : 567 - 574
  • [4] Validity, reliability, and responsiveness of Persian version of mini-balance evaluation system test among ambulatory people with multiple sclerosis
    Molhemi, Farshad
    Monjezi, Saeideh
    Mehravar, Mohammad
    Shaterzadeh-Yazdi, Mohammad-Jafar
    Majdinasab, Nastaran
    PHYSIOTHERAPY THEORY AND PRACTICE, 2024, 40 (03) : 565 - 575
  • [5] Reliability, Validity, and Responsiveness of the Mini-Balance Evaluation Systems Test in Ambulatory Individuals with Multiple Sclerosis
    Potter, Kirsten
    Bowling, Rachel
    Kavanagh, Lindsey
    Stone, Ashley
    Witt, Brittany
    Wooldridge, Ashley
    PHYSIOTHERAPY CANADA, 2019, 71 (04) : 327 - 334
  • [6] Psychometric properties of the Arabic version of the Mini-Balance Evaluation Systems Test in patients with neurological balance disorders
    Alyousef, N. I.
    Shaheen, A. A. M.
    Elsayed, W.
    Alsubiheen, A. M.
    Farrag, A.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2023, 27 (10) : 4337 - 4347
  • [7] Structural Validity of the Mini-Balance Evaluation Systems Test in Individuals With Spinocerebellar Ataxia: A Rasch Analysis Study
    Miyata, Kazuhiro
    Kondo, Yuki
    Bando, Kyota
    Hara, Takatoshi
    Takahashi, Yuji
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2024, 105 (04): : 742 - 749
  • [8] Reliability and Validity of the Turkish Version of the Mini-BESTest Balance Scale in Patients with Stroke
    Goktas, Ayse
    Colak, Fulya Damla
    Kar, Irem
    Ekici, Gamze
    TURKISH JOURNAL OF NEUROLOGY, 2020, 26 (04) : 303 - 310
  • [9] The Evaluation of Gait and Balance for Patients with Early Diabetic Peripheral Neuropathy: A Cross-Sectional Study
    Jiang, Xiaoyan
    Deng, Fang
    Rui, Shunli
    Ma, Yu
    Wang, Min
    Deng, Bo
    Wang, Hongyan
    Du, Chenzhen
    Chen, Bing
    Yang, Xiuhua
    Boey, Johnson
    Armstrong, David G.
    Deng, Wuquan
    Duan, Xiaodong
    RISK MANAGEMENT AND HEALTHCARE POLICY, 2022, 15 : 543 - 552
  • [10] Structural Validity of the Mini-Balance Evaluation Systems Test (Mini-BESTest) in People With Mild to Moderate Parkinson Disease
    Wallen, Martin Benka
    Sorjonen, Kimmo
    Lofgren, Niklas
    Franzen, Erika
    PHYSICAL THERAPY, 2016, 96 (11): : 1799 - 1806