A comparative evaluation of mandibular finite element models with different lengths and elements for implant biomechanics

被引:71
作者
Teixeira, ER [1 ]
Sato, Y [1 ]
Akagawa, Y [1 ]
Shindoi, N [1 ]
机构
[1] Hiroshima Univ, Sch Dent, Dept Removable Prosthodont, Minami Ku, Hiroshima 7348553, Japan
关键词
D O I
10.1111/j.1365-2842.1998.00244.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Further validity of finite element analysis (FEA) in implant biomechanics requires an increase of modelled range and mesh refinement, and a consequent increase in element number and calculation time. To develop a new method that allows a decrease of the modelled range and element number (along with less calculation time and less computer memory), 10 FEA models of the mandible with different mesio-distal lengths and elements were constructed based on three-dimensional graphic data of the bone structure around an osseointegrated implant. Analysis of stress distribution followed by 100 N loading with the fixation of the most external planes of the models indicated that a minimal bone length of 4.2 mm of the mesial and distal sides was acceptable for FEA representation. Moreover, unification of elements located far away from the implant surface did not affect stress distribution. These results suggest that it may be possible to develop a replica FEA implant model of the mandible with less range and fewer elements without altering stress distribution.
引用
收藏
页码:299 / 303
页数:5
相关论文
共 14 条
[1]   THE 3-DIMENSIONAL BONE INTERFACE OF AN OSSEOINTEGRATED IMPLANT - A METHOD FOR STUDY [J].
AKAGAWA, Y ;
WADAMOTO, M ;
SATO, Y ;
TSURU, H .
JOURNAL OF PROSTHETIC DENTISTRY, 1992, 68 (05) :813-816
[2]  
BELL G. H., 1967, CALCIFIED TISSUE RES, V1, P75, DOI 10.1007/BF02008077
[3]  
Branemark P, 1987, TISSUE INTEGRATED PR, P129
[4]  
Holmes D C, 1992, Int J Oral Maxillofac Implants, V7, P450
[5]  
Lewinstein I, 1995, Int J Oral Maxillofac Implants, V10, P355
[6]   THE INFLUENCE OF A FLEXIBLE COATING ON THE BONE STRESS AROUND DENTAL IMPLANTS [J].
MEIJER, GJ ;
STARMANS, FJM ;
DEPUTTER, C ;
VANBLITTERSWIJK, CA .
JOURNAL OF ORAL REHABILITATION, 1995, 22 (02) :105-111
[7]   A 3-DIMENSIONAL, FINITE-ELEMENT ANALYSIS OF BONE AROUND DENTAL IMPLANTS IN AN EDENTULOUS HUMAN MANDIBLE [J].
MEIJER, HJA ;
STARMANS, FJM ;
STEEN, WHA ;
BOSMAN, F .
ARCHIVES OF ORAL BIOLOGY, 1993, 38 (06) :491-496
[8]  
MIDDLETON J, 1996, COMPUTER METHODS BIO, P125
[9]  
Moroi H H, 1993, Int J Prosthodont, V6, P564
[10]   BONE STRESS-DISTRIBUTION FOR 3 ENDOSSEOUS IMPLANTS [J].
RIEGER, MR ;
FAREED, K ;
ADAMS, WK ;
TANQUIST, RA .
JOURNAL OF PROSTHETIC DENTISTRY, 1989, 61 (02) :223-228