Can photon IMRT be improved by combination with mixed electron and photon techniques?

被引:28
作者
Mu, XK [1 ]
Olofsson, L [1 ]
Karlsson, M [1 ]
Sjögren, R [1 ]
Zackrisson, B [1 ]
机构
[1] Umea Univ, Dept Radiat Sci, SE-90187 Umea, Sweden
关键词
D O I
10.1080/02841860410002761
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Conformal radiotherapy or intensity modulated radiotherapy (IMRT) commonly leads to a large integral dose in the patient. Electrons would reduce the integral dose but are not suitable for treating deep-seated tumours, owing to their limited penetration. By combining electron and photon beams, the dose distributions may be improved. In this study, the possibility is explored of using a mixture of electron and photon beams for a deep-seated target volume in the head and neck region. Treatment plans were made for five simulated head and neck cancer cases. Mixed electron and photon beam plans (MB) were constructed using a manual iterative procedure. Photon IMRT plans were optimized automatically. Both electron and photon beams were collimated by a computer controlled multi-leaf collimator (MLC). Both methods were able to produce clinically acceptable plans. Criteria for the target dose were met similarly by both as were the criteria for critical organs. The integral dose outside the planning target volume (PTV) showed a tendency to be lower with MB plans compared with photon IMRT plans. A mixed electron and photon technique has the potential to treat deep-seated tumours. It is reasonable to expect that if computerized optimization tools were coupled with the mixed electron and photon beam technique, treatment goals would be more readily achieved than if using solely pure photon IMRT.
引用
收藏
页码:727 / 735
页数:9
相关论文
共 37 条
  • [31] Tubiana M, 2000, ACTA ONCOL, V39, P555
  • [32] The potential of proton and light ion beams in radiotherapy
    Turesson, I
    Johansson, KA
    Mattsson, S
    [J]. ACTA ONCOLOGICA, 2003, 42 (02) : 107 - 114
  • [33] Is uniform target dose possible in IMRT plans in the head and neck?
    Vineberg, KA
    Eisbruch, A
    Coselmon, MM
    McShan, DL
    Kessler, ML
    Fraass, BA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 52 (05): : 1159 - 1172
  • [34] The potential for sparing of parotids and escalation of biologically effective dose with intensity-modulated radiation treatments of head and neck cancers: A treatment design study
    Wu, QW
    Manning, M
    Schmidt-Ullrich, R
    Mohan, R
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 46 (01): : 195 - 205
  • [35] A systematic overview of radiation therapy effects in head and neck cancer
    Zackrisson, B
    Mercke, C
    Strander, H
    Wennerberg, J
    Cavallin-Ståhl, E
    [J]. ACTA ONCOLOGICA, 2003, 42 (5-6) : 443 - 461
  • [36] Matching of electron beams for conformal therapy of target volumes at moderate depths
    Zackrisson, B
    Karlsson, M
    [J]. RADIOTHERAPY AND ONCOLOGY, 1996, 39 (03) : 261 - 270
  • [37] Potential of intensity-modulated radiotherapy to escalate doses to head-and-neck cancers: What is the maximal dose?
    Zhou, JN
    Fe, DY
    Wu, QW
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 57 (03): : 673 - 682