Can photon IMRT be improved by combination with mixed electron and photon techniques?

被引:28
作者
Mu, XK [1 ]
Olofsson, L [1 ]
Karlsson, M [1 ]
Sjögren, R [1 ]
Zackrisson, B [1 ]
机构
[1] Umea Univ, Dept Radiat Sci, SE-90187 Umea, Sweden
关键词
D O I
10.1080/02841860410002761
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Conformal radiotherapy or intensity modulated radiotherapy (IMRT) commonly leads to a large integral dose in the patient. Electrons would reduce the integral dose but are not suitable for treating deep-seated tumours, owing to their limited penetration. By combining electron and photon beams, the dose distributions may be improved. In this study, the possibility is explored of using a mixture of electron and photon beams for a deep-seated target volume in the head and neck region. Treatment plans were made for five simulated head and neck cancer cases. Mixed electron and photon beam plans (MB) were constructed using a manual iterative procedure. Photon IMRT plans were optimized automatically. Both electron and photon beams were collimated by a computer controlled multi-leaf collimator (MLC). Both methods were able to produce clinically acceptable plans. Criteria for the target dose were met similarly by both as were the criteria for critical organs. The integral dose outside the planning target volume (PTV) showed a tendency to be lower with MB plans compared with photon IMRT plans. A mixed electron and photon technique has the potential to treat deep-seated tumours. It is reasonable to expect that if computerized optimization tools were coupled with the mixed electron and photon beam technique, treatment goals would be more readily achieved than if using solely pure photon IMRT.
引用
收藏
页码:727 / 735
页数:9
相关论文
共 37 条
  • [1] COLLAPSED CONE CONVOLUTION OF RADIANT ENERGY FOR PHOTON DOSE CALCULATION IN HETEROGENEOUS MEDIA
    AHNESJO, A
    [J]. MEDICAL PHYSICS, 1989, 16 (04) : 577 - 592
  • [2] [Anonymous], 1993, 50 ICRU
  • [3] [Anonymous], 2000, J Jpn Soc Ther Radiol Oncol, V12, P191
  • [4] [Anonymous], 1999, 62 ICRU
  • [5] Optimization of 3D conformal electron beam therapy in inhomogeneous media by concomitant fluence and energy modulation
    Asell, M
    Hyodynmaa, S
    Gustafsson, A
    Brahme, A
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (11) : 2083 - 2100
  • [6] Test procedures for verification of an electron pencil beam algorithm implemented for treatment planning
    Blomquist, M
    Karlsson, M
    Karlsson, M
    [J]. RADIOTHERAPY AND ONCOLOGY, 1996, 39 (03) : 271 - 286
  • [7] Multileaf collimation of electrons-clinical effects on electron energy modulation and mixed beam therapy depending on treatment head design
    Blomquist, M
    Karlsson, MG
    Zackrisson, B
    Karlsson, M
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (07) : 1013 - 1024
  • [8] Modulated beam conformal therapy for head and neck tumors
    Boyer, AL
    Geis, P
    Grant, W
    Carol, M
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (01): : 227 - 236
  • [9] Three-dimensional conformal vs. intensity-modulated radiotherapy in head-and-neck cancer patients: Comparative analysis of dosimetric and technical parameters
    Cozzi, L
    Fogliata, A
    Bolsi, A
    Nicolini, G
    Bernier, J
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 58 (02): : 617 - 624
  • [10] Dose, volume, and function relationships in parotid salivary glands following conformal and intensity-modulated irradiation of head and neck cancer
    Eisbruch, A
    Ten Haken, RK
    Kim, HM
    Marsh, LH
    Ship, JA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (03): : 577 - 587