Load Modelling Effects on Power System Inertia Response

被引:0
作者
Rainey, M. J. [1 ]
Oyedokun, D. T. O. [1 ]
机构
[1] Univ Cape Town, Dept Elect Engn, Cape Town, South Africa
来源
2020 IEEE PES & IAS POWERAFRICA CONFERENCE | 2020年
关键词
Frequency Stability; Inertia Response; Load Modelling; System Inertia; Load Characteristics;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
As countries around the world begin to increase the contribution of renew able energy generation into their interconnected power systems, a large portion of this generation is interfaced to the power system through power electronic converters. As the increase in their contribution begins to displace traditional synchronous generation through end of life and/or early decommissioning, the power system inertia will decrease. This increases the rate of change of frequency (ROCOF) making the frequency of the system respond quicker to power imbalances. In this paper, load modelling and their effects on ROCOF are explored to highlight the key considerations when deriving conclusions based on the power system inertia outlook. The outcome showed that more realistic composite load structures based on type of loads that reflect the corresponding economic activity will present different outlooks on the inertia response of the power system. The outcome of this research also demonstrates how composite load modelling effects on the network and interlinked transmission line loading can result in lower frequency nadir and ROCOF. This outcome is very critical in understanding the dynamic loading conditions on transmission lines against possible contingencies and the network inertia status.
引用
收藏
页数:5
相关论文
共 10 条
  • [1] Abdalla O. H., 2008, 2008 12th International Middle-East Power System Conference, P270, DOI 10.1109/MEPCON.2008.4562351
  • [2] LOAD REPRESENTATION IN POWER SYSTEM STABILITY STUDIES
    CONCORDIA, C
    IHARA, S
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1982, 101 (04): : 969 - 977
  • [3] Jin Ma, 2006, 2006 IEEE Power Engineering Society General Meeting
  • [4] COMPARISON OF SIMULATED POWER-SYSTEM DYNAMICS APPLYING VARIOUS LOAD MODELS WITH ACTUAL RECORDED DATA
    KAO, WS
    LIN, CJ
    HUANG, CT
    CHEN, YT
    CHIOU, CY
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 1994, 9 (01) : 248 - 254
  • [5] Model validation for the August 10, 1996 WSCC system outage
    Kosterev, DN
    Taylor, CW
    Mittelstadt, WA
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 1999, 14 (03) : 967 - 974
  • [6] Kundur P., 1994, Power system stability and control
  • [7] P. A. EPRI CA and Public Service Company of New Mexico Albuquerque NM, 2002, ADV LOAD MODELLING
  • [8] Polychronidou E., 2019, 2019 IEEE MIL POW, P1, DOI [10.1109/CIBCB.2019.8791462, DOI 10.1109/ptc.2019.8810827]
  • [9] Polykarpou E., 2018, 2018 IEEE INT C SCI
  • [10] Transmission Line Damping Effects on Power System Inertia Response
    Rainey, M. J.
    Oyedokun, D. T. O.
    [J]. 2020 INTERNATIONAL SAUPEC/ROBMECH/PRASA CONFERENCE, 2020, : 445 - 450