Breathheld Autocalibrated Phase-Contrast Imaging

被引:3
作者
Lew, Calvin [1 ,2 ]
Alley, Marcus T. [1 ]
Spielman, Daniel M. [1 ]
Bammer, Roland [1 ]
Chan, Frandics P. [1 ]
机构
[1] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
关键词
phase-contrast; GRAPPA; SENSE; parallel imaging; SHUNT QUANTIFICATION; SEPTAL-DEFECTS; HEART-DISEASE; RESONANCE; SENSE; GRAPPA; FLOW; MRI; RECONSTRUCTION; VOLUME;
D O I
10.1002/jmri.22127
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare generalized autocalibrating partially parallel acquisitions (GRAPPA). modified sensitivity encoding (mSENSE), and SENSE in phase-contrast magnetic resonance imaging (PC-MRI) applications. Materials and Methods: Aliasing of the torso can occur in PC-MRI applications. If the data are further under-sampled for parallel imaging. SENSE can be problematic in correctly unaliasing signals due to coil sensitivity maps that do not match that of the aliased volume. Here, a method for estimating coil sensitivities in flow applications is described. Normal volunteers (n = 5) were scanned on a 1.5 T MRI scanner and underwent PC-MRI scans using GRAPPA. mSENSE, SENSE, and conventional PC-MRI acquisitions. Peak velocity and flow through the aorta and pulmonary artery were evaluated. Results: Bland-Altman statistics for flow in the aorta and pulmonary artery acquired with mSENSE and GRAPPA methods (R = 2 and R = 3 cases) have comparable mean differences to flow acquired with conventional PC-MRI. GRAPPA and mSENSE PC-MRI have more robust measurements than SENSE when there is aliasing artifact caused by insufficient coil sensitivity maps. For peak velocity, there are no considerable differences among the mSENSE, GRAPPA, and SENSE reconstructions and are comparable to conventional PC-MRI. Conclusion: Flow measurements of images reconstructed with autocalibration techniques have comparable agreement with conventional PC-MRI and provide robust measurements in the presence of wraparound.
引用
收藏
页码:1004 / 1014
页数:11
相关论文
共 25 条
  • [1] [Anonymous], 2006, P INT SOC MAGNETIC R
  • [2] Rapid left-to-right shunt quantification in children by phase-contrast magnetic resonance imaging combined with sensitivity encoding
    Beerbaum, P
    Körperich, H
    Gieseke, J
    Barth, P
    Peuster, M
    Meyer, H
    [J]. CIRCULATION, 2003, 108 (11) : 1355 - 1361
  • [3] Concomitant gradient terms in phase contrast MR: Analysis and correction
    Bernstein, MA
    Zhou, XHJ
    Polzin, JA
    King, KF
    Ganin, A
    Pelc, NJ
    Glover, GH
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (02) : 300 - 308
  • [4] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [5] MRI of supracristal ventricular septal defects
    Bremerich, J
    Reddy, GP
    Higgins, CB
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 (01) : 13 - 15
  • [6] QUANTIFICATION OF LEFT-TO-RIGHT ATRIAL SHUNTS WITH VELOCITY-ENCODED CINE NUCLEAR-MAGNETIC-RESONANCE IMAGING
    BRENNER, LD
    CAPUTO, GR
    MOSTBECK, G
    STEIMAN, D
    DULCE, M
    CHEITLIN, MD
    OSULLIVAN, M
    HIGGINS, CB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (05) : 1246 - 1250
  • [7] The SENSE ghost: Field-of-view restrictions for SENSE imaging
    Goldfarb, JW
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (06) : 1046 - 1051
  • [8] Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA)
    Griswold, MA
    Jakob, PM
    Heidemann, RM
    Nittka, M
    Jellus, V
    Wang, JM
    Kiefer, B
    Haase, A
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) : 1202 - 1210
  • [9] Field-of-view limitations in parallel imaging
    Griswold, MA
    Kannengiesser, S
    Heidemann, RM
    Wang, JM
    Jakob, PM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (05) : 1118 - 1126
  • [10] Heart disease: Functional evaluation with MR imaging
    Higgins, CB
    Sakuma, H