Time Course of Electrical Impedance During Red Blood Cell Aggregation in a Glass Tube: Comparison With Light Transmittance

被引:42
作者
Baskurt, Oguz K. [1 ]
Uyuklu, Mehmet [1 ]
Meiselman, Herbert J. [2 ]
机构
[1] Akdeniz Univ, Fac Med, Dept Physiol, TR-07070 Antalya, Turkey
[2] Univ So Calif, Keck Sch Med, Dept Physiol & Biophys, Los Angeles, CA 90033 USA
基金
美国国家卫生研究院;
关键词
Capacitance; impedance measurement; light transmittance (LT); red blood cell (RBC) aggregation; ERYTHROCYTE AGGREGATION; DIELECTRIC APPROACH; STIRRING-SYSTEM; CONDUCTIVITY; SUSPENSIONS; RHEOLOGY; DEFORMABILITY; KINETICS; RECOVERY;
D O I
10.1109/TBME.2009.2036598
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Red blood cells (RBC) in normal human blood undergo reversible aggregation at low flow or stasis. The extent and kinetics of this phenomenon have been studied using various optical and electrical methods, yet results using such methods are not always in concordance. This study employed a horizontal glass tube in which blood flow could be established, then abruptly stopped. Normal blood and RBC suspensions with enhanced or decreased aggregation were studied. Light transmittance (LT) and electrical impedance at 100 kHz were recorded during high-shear flow and for 120 s after flow was abruptly stopped during which RBC aggregation occurs. Capacitance values were also obtained based on the imaginary part of impedance data and recorded. Various aggregation parameters were calculated, using the time course of LT, impedance, and capacitance, then compared with each other and with results from laboratory aggregometers. RBC aggregation parameters were calculated, using the time course of impedance data often failed to correlate with known changes of aggregation, even reporting aggregation for cells in nonaggregating media (i.e., RBC in buffered saline). Alternatively, RBC aggregation parameters based upon the time course of capacitance data are in general agreement with those derived from LT data and with RBC aggregation indexes, measured using commercial instruments.
引用
收藏
页码:969 / 978
页数:10
相关论文
共 51 条
[1]  
Antonova N, 2006, CLIN HEMORHEOL MICRO, V35, P19
[2]   Time dependent variation of human blood conductivity as a method for an estimation of RBC aggregation [J].
Antonova, Nadia ;
Riha, Pavel ;
Ivanov, Ivan .
CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2008, 39 (1-4) :69-78
[3]  
Balan C, 2004, CLIN HEMORHEOL MICRO, V30, P359
[5]   Simultaneous monitoring of electrical conductance and light transmittance during red blood cell aggregation [J].
Baskurt, O. K. ;
Uyuklu, M. ;
Meiselman, H. J. .
BIORHEOLOGY, 2009, 46 (03) :239-249
[6]  
Baskurt OK, 2007, BIOMED HEALTH RES, V69, P170
[7]   Comparison of three instruments for measuring red blood cell aggregation [J].
Baskurt, Oguz K. ;
Uyuklu, Mehmet ;
Ulker, Pinar ;
Cengiz, Melike ;
Nemeth, Norbert ;
Alexy, Tamas ;
Shin, Sehyun ;
Hardeman, Max R. ;
Meiselman, Herbert J. .
CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2009, 43 (04) :283-298
[8]   New guidelines for hemorheological laboratory techniques [J].
Baskurt, Oguz K. ;
Boynard, Michel ;
Cokelet, Giles C. ;
Connes, Philippe ;
Cooke, Brian M. ;
Forconi, Sandro ;
Liao, Fulong ;
Hardeman, Max R. ;
Jung, Friedrich ;
Meiselman, Herbert J. ;
Nash, Gerard ;
Nemeth, Norbert ;
Neu, Bjoern ;
Sandhagen, Bo ;
Shin, Sehyun ;
Thurston, George ;
Wautier, Jean Luc .
CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2009, 42 (02) :75-97
[9]   In vivo correlates of altered blood rheology [J].
Baskurt, Oguz K. .
BIORHEOLOGY, 2008, 45 (06) :629-638
[10]   Determination of red blood cell shape recovery time constant in a Couette system by the analysis of light reflectance and ektacytometry [J].
Baskurt, OK ;
Meiselman, HJ .
BIORHEOLOGY, 1996, 33 (06) :489-503