Imaging mass spectrometry using a delay-line detector

被引:16
|
作者
Froesch, Martin [1 ]
Luxembourg, Stefan L. [1 ]
Verheijde, Duncan [1 ]
Heeren, Ron M. A. [1 ]
机构
[1] FOM, Inst Atom & Mol Phys, NL-1098 XG Amsterdam, Netherlands
关键词
MALDI; SIMS; detectors; imaging MS; cancer; lipidomics; proteomics; data acquisition; SUBCELLULAR-LOCALIZATION; TISSUE-SECTIONS; PROTEINS; SURFACE; MS; MICROSCOPY; PROTEOMICS; PEPTIDES; SCALE; SIMS;
D O I
10.1255/ejms.1052
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Microscope mode mass spectrometric imaging is crucially dependent on the availability of a high-resolution, position-resolved time-of-flight detector. Here, a new detection method for microscope mode imaging mass spectrometry is presented. A delay-line detector has been used for the first time as a position-sensitive detector in imaging mass spectrometry. The method is implemented on a matrix-assisted laser desorption/ionization time-of-flight (MALDI-ToF), as well as a secondary ion mass spectrometry time-of-flight (SIMS-ToF) instrument. Trypsinogen and bovine serum albumin samples have been used with a metal mask to determine the spatial resolution of the new detector using the MALDI-ToF instrument. The new detector set-up was successfully employed to generate mass resolved SIMS images from biological structures on the surface of thin tissue sections. The biological samples studied were taken from tumor grown from xenografted breast cancer cell lines and chicken embryonal sections.
引用
收藏
页码:35 / 45
页数:11
相关论文
共 50 条
  • [41] High impedance discrete delay-line readout circuit for silicon strip detector
    Vind, R. P.
    Inkar, A. L.
    Choudhury, R. K.
    Nayak, B. K.
    Saxena, A.
    Thomas, R. G.
    Biswas, D. C.
    John, B. V.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (03): : 1435 - 1440
  • [42] A POSITION-SENSITIVE PARTICLE DETECTOR WITH A MEANDER-TYPE DELAY-LINE
    LIU, B
    LIESEN, D
    ENDERS, W
    SCHULZE, R
    WARCZAK, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 240 (01): : 139 - 144
  • [43] DPSK SIGNAL DEMODULATION USING ACOUSTOOPTIC DELAY-LINE
    KULAKOV, VS
    NIKITIN, YI
    NIKIFOROVA, EY
    PRESLENEV, LN
    RADIOTEKHNIKA I ELEKTRONIKA, 1989, 34 (08): : 1756 - 1759
  • [44] Physical characteristics of delay-line current-biased kinetic inductance detector
    Iizawa, Yuki
    Yamaguchi, Hiroyuki
    Miki, Yuya
    Nishimura, Kazuma
    Shishido, Hiroaki
    Kojima, Kenji M.
    Oikawa, Kenichi
    Harada, Masahide
    Miyajima, Shigeyuki
    Hidaka, Mutsuo
    Oku, Takayuki
    Soyama, Kazuhiko
    Koyama, Tomio
    Ishida, Takekazu
    30TH INTERNATIONAL SYMPOSIUM ON SUPERCONDUCTIVITY (ISS2017), 2018, 1054
  • [45] MAGNETIC DELAY-LINE STORAGE
    WANG, A
    PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1951, 39 (04): : 401 - 407
  • [46] STABLE DIGITAL DELAY-LINE
    DOLGII, BY
    ELISEEV, AB
    ZAGIDULLIN, RS
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1987, 30 (01) : 101 - 103
  • [47] PRINTED SYMMETRICAL DELAY-LINE
    VISHNEVSKII, VN
    NEMIROVSKII, VM
    KHODAK, GI
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1978, 21 (02) : 414 - 416
  • [48] MEMBRANE WAVE DELAY-LINE
    LUUKKALA, M
    MERILAINEN, P
    ELECTRONICS LETTERS, 1978, 14 (04) : 123 - 124
  • [49] CORRELATION AND DELAY-LINE ATTENUATION
    JACOBSON, MJ
    IRE TRANSACTIONS ON INFORMATION THEORY, 1959, 5 (01): : 4 - 9
  • [50] A DESIGN OF AN ULTRASONIC DELAY-LINE
    GOLD, T
    PHILOSOPHICAL MAGAZINE, 1951, 42 (330): : 787 - 791