Imaging mass spectrometry using a delay-line detector

被引:16
|
作者
Froesch, Martin [1 ]
Luxembourg, Stefan L. [1 ]
Verheijde, Duncan [1 ]
Heeren, Ron M. A. [1 ]
机构
[1] FOM, Inst Atom & Mol Phys, NL-1098 XG Amsterdam, Netherlands
关键词
MALDI; SIMS; detectors; imaging MS; cancer; lipidomics; proteomics; data acquisition; SUBCELLULAR-LOCALIZATION; TISSUE-SECTIONS; PROTEINS; SURFACE; MS; MICROSCOPY; PROTEOMICS; PEPTIDES; SCALE; SIMS;
D O I
10.1255/ejms.1052
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Microscope mode mass spectrometric imaging is crucially dependent on the availability of a high-resolution, position-resolved time-of-flight detector. Here, a new detection method for microscope mode imaging mass spectrometry is presented. A delay-line detector has been used for the first time as a position-sensitive detector in imaging mass spectrometry. The method is implemented on a matrix-assisted laser desorption/ionization time-of-flight (MALDI-ToF), as well as a secondary ion mass spectrometry time-of-flight (SIMS-ToF) instrument. Trypsinogen and bovine serum albumin samples have been used with a metal mask to determine the spatial resolution of the new detector using the MALDI-ToF instrument. The new detector set-up was successfully employed to generate mass resolved SIMS images from biological structures on the surface of thin tissue sections. The biological samples studied were taken from tumor grown from xenografted breast cancer cell lines and chicken embryonal sections.
引用
收藏
页码:35 / 45
页数:11
相关论文
共 50 条
  • [21] OPTICAL DELAY-LINE
    MECKLEY, JR
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1974, 45 (01): : 123 - 123
  • [22] ENERGY RESOLUTION USING DELAY-LINE DETECTORS
    GABRIEL, A
    DAUVERGNE, F
    NOLTING, HF
    KOCH, MHJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 349 (2-3): : 461 - 465
  • [23] A MECHANICAL DELAY-LINE
    FRANK, M
    IEEE ANNALS OF THE HISTORY OF COMPUTING, 1992, 14 (03) : 6 - 6
  • [24] TEMPERATURE SENSOR USING SAW DELAY-LINE
    HAUDEN, D
    JAILLET, G
    COQUEREL, R
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1982, 29 (03): : 187 - 187
  • [25] A MECHANICAL DELAY-LINE
    HALL, C
    IEEE ANNALS OF THE HISTORY OF COMPUTING, 1992, 14 (01) : 9 - 9
  • [26] A RECOIL PROTON DETECTOR USING CYLINDRICAL MULTIWIRE PROPORTIONAL CHAMBERS WITH DELAY-LINE CATHODE READOUTS
    AMBATS, I
    ARENTON, MW
    AYRES, DS
    DAWSON, J
    DIEBOLD, R
    MAY, EN
    SAUER, JR
    WALSCHON, E
    WICKLUND, AB
    SWALLOW, EC
    NUCLEAR INSTRUMENTS & METHODS, 1980, 174 (03): : 427 - 438
  • [27] Design of a delay-line position-sensitive detector with improved performance
    Da Costa, G
    Vurpillot, F
    Bostel, A
    Bouet, M
    Deconihout, B
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (01):
  • [28] PROPORTIONAL CHAMBERS WITH DELAY-LINE READOUT IN THE MD-1 DETECTOR
    AULCHENKO, VM
    BONDAR, AE
    FILIMONOV, GS
    KOLACHEV, GM
    MINAKOV, GD
    ONUCHIN, AP
    PANIN, VS
    RODYAKIN, VA
    TELNOV, VI
    ZHILICH, VN
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 252 (2-3): : 267 - 271
  • [29] LASER WITH A DELAY-LINE
    DYTYNKO, VM
    NAUMKIN, NI
    KORNIYENKO, LS
    KRAVTSOV, NV
    RADIO ENGINEERING AND ELECTRONIC PHYSICS-USSR, 1971, 16 (03): : 563 - +
  • [30] AN ELECTROMAGNETIC SHOWER DETECTOR USING PROPORTIONAL WIRE CHAMBERS WITH CATHODE PLANE DELAY-LINE READOUT
    NUNAMAKER, TA
    HEISTERBERG, RH
    MO, LW
    NUCLEAR INSTRUMENTS & METHODS, 1980, 175 (2-3): : 331 - 334