Safety and Cost-Effectiveness of Same Day Permanent Pacemaker Implantation

被引:24
作者
Osman, Faizel [1 ]
Krishnamoorthy, Suresh [2 ]
Nadir, Adnan [2 ]
Mullin, Phillip [2 ]
Morley-Davies, Adrian [2 ]
Creamer, John [2 ]
机构
[1] Univ Hosp Coventry, Dept Cardiol, Coventry, W Midlands, England
[2] N Staffordshire Natl Hlth Serv Trust, Univ Hosp, City Gen Hosp, Stoke On Trent, Staffs, England
关键词
ANTIBIOTIC-PROPHYLAXIS; TRANSVENOUS PACEMAKERS; INFECTIONS; SURGERY; TRIAL;
D O I
10.1016/j.amjcard.2010.03.038
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
An overnight stay after permanent pacemaker implantation has major cost implications for healthcare systems. Same day pacing could be effective in alleviating this. We evaluated our elective same day pacing practice to determine safety and cost-effectiveness. A total of 780 patients were scheduled for elective new permanent pacemaker implantation as a same day procedure at the University Hospital, North Staffordshire, from April 2001 to December 2006. The mean age +/- SEM of the cohort was 73.8 +/- 0.4 years (464 men and 316 women). Single-chamber devices were implanted in 272 (27 atrial and 245 ventricular) and dual chamber in 508 patients. Vascular access was by the subclavian vein in 431 patients and the cephalic vein in 349. Preimplant intravenous antibiotics were administered to 28% and perioperative antibiotics to the remainder; all patients received oral antibiotics after implantation. Of the 780 patients, 41 (5.3%) required an in-hospital stay after implantation because of hematoma formation in 12, pneumothorax in 3, social reasons for 7, observation at the physicians request but no complication for 13, angina in 3, arrhythmia in 1, and warfarin therapy in 2. Immediate complications (<24 hours) occurred in 6 patients and early complications (>24 hours to 6 weeks) developed in 17. Of the 780 patients, 94 had died at mean follow-up of 2.4 +/- 0.1 years; none were related to pacemaker implantation. An overnight stay at our hospital costs 203.60 pound (similar to US$305). From November 2005 to November 2006, 109 patients underwent same day implantation, resulting in a cost saving of 22,192.40 pound (similar to US$34,500). In conclusion, same day permanent pacemaker implantation was feasible, safe, and cost-effective. It was associated with a low prevalence of complications and only a few patients required an overnight stay. (C) 2010 Elsevier Inc. All rights reserved. (Am J Cardiol 2010;106:383-385)
引用
收藏
页码:383 / 385
页数:3
相关论文
共 19 条
[1]   OUTPATIENT PACEMAKER PROCEDURES [J].
BELOTT, PH .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 1987, 17 (02) :169-176
[2]  
BLUHM G, 1985, ACTA MED SCAND, P1
[3]   ANTIBIOTIC-PROPHYLAXIS IN PACEMAKER SURGERY - A PROSPECTIVE TRIAL WITH LOCAL OR SYSTEMIC ADMINISTRATION OF ANTIBIOTICS AT GENERATOR REPLACEMENTS [J].
BLUHM, G ;
JACOBSON, B ;
RANSJO, U .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1985, 8 (05) :661-670
[4]   Increasing rates of cardiac device infections among Medicare beneficiaries: 1990-1999 [J].
Cabell, CH ;
Heidenreich, PA ;
Chu, VH ;
Moore, CM ;
Stryjewski, ME ;
Corey, GR ;
Fowler, VG .
AMERICAN HEART JOURNAL, 2004, 147 (04) :582-586
[5]  
CHARDACK WM, 1960, SURGERY, V48, P643
[6]  
CONKLIN EF, 1975, J THORAC CARDIOV SUR, V69, P1
[7]   Antibiotic prophylaxis for permanent pacemaker implantation - A meta-analysis [J].
Da Costa, A ;
Kirkorian, G ;
Cucherat, M ;
Delahaye, F ;
Chevalier, P ;
Cerisier, A ;
Isaaz, K ;
Touboul, P .
CIRCULATION, 1998, 97 (18) :1796-1801
[8]   SURGICAL REMOVAL OF INFECTED TRANSVENOUS PACEMAKER LEADS [J].
FRAME, R ;
BRODMAN, RF ;
FURMAN, S ;
ANDREWS, CA ;
GROSS, JN .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (12) :2343-2348
[9]   INSERTION OF PERMANENT PACEMAKERS AS A DAY CASE PROCEDURE [J].
HAYWOOD, GA ;
CAMM, AJ ;
WARD, DE .
BRITISH MEDICAL JOURNAL, 1989, 299 (6708) :1139-1139
[10]   COMPLICATIONS OF PERMANENT TRANSVENOUS CARDIAC PACING - A 14-YEAR REVIEW OF ALL TRANSVENOUS PACEMAKERS INSERTED AT ONE COMMUNITY-HOSPITAL [J].
HILL, PE .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (03) :564-570