Glaucoma detection with frequency doubling perimetry and short-wave length perimetry

被引:13
作者
Horn, Folkert K.
Brenning, Alexander
Juenemann, Anselm G.
Lausen, Berthold
机构
[1] Univ Erlangen Nurnberg, Augenklin, Dept Ophthalmol, D-91054 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Hosp Eye, D-91054 Erlangen, Germany
[3] Univ Erlangen Nurnberg, Dept Med Informat Biometry & Epidemiol, D-91054 Erlangen, Germany
关键词
glaucoma; frequency doubling technique; short-wavelength perimetry; machine-learning technique; double-bagging; WAVELENGTH AUTOMATED PERIMETRY; BLUE-ON-YELLOW; VISUAL-FIELD LOSS; SCANNING LASER POLARIMETRY; TEST-RETEST VARIABILITY; FIBER LAYER THICKNESS; OPTIC DISC; TECHNOLOGY PERIMETRY; FOLLOW-UP; CLASSIFICATION;
D O I
10.1097/IJG.0b013e318032e4c2
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The aim of this analysis was to evaluate the diagnostic usefulness of frequency doubling technology (FDT) perimetry and short-wavelength perimetry (SWAP). Moreover, to study a combination of both methods using the machine-learning technique double-bagging, which was recently established in glaucoma research. Methods: Forty-three patients with "preperimetric" open-angle glaucoma (glaucomatous optic disc atrophy and no visual field defect in standard perimetry), 26 patients with "perimetric" open angle glaucoma (glaucomatous optic disc atrophy and visual field defect in standard perimetry), and 40 control subjects had FDT screening (protocol: C-20-5) and SWAP (Octopus 101, G2). Criteria for exclusion were color vision abnormalities, media opacities, and an age below 31 years or above 63 years. Data of I eye of each patient and control subject entered the statistical evaluation. A point wise evaluation of the diagnostic power of SWAP values was performed to derive spatial patterns of visual field loss. A double-bagging machine-learning algorithm was used to train classification rules on the basis of a combination of FDT scores and nerve fiber related visual field losses in SWAP. The diagnostic power of the classifiers was compared regarding their misclassification error rates and area under the receiver-operating characteristic curve. Results: The combination of FDT perimetry and SWAP yielded better diagnostic results compared with FDT or SWAP separately. The overall estimated misclassification error rate of the combined classifier was 24% compared with 28% for both SWAP and FDT perimetry. Regarding the estimated performance of classifier at high specificities ( > 80%) in control eyes as measured by the partial area under the receiver- operating characteristic curve, the combination of both instruments is also superior to the individual instruments. Conclusions: A combination of SWAP and FDT perimetry, each targeting different neuronal pathways, may improve early glaucoma detection.
引用
收藏
页码:363 / 371
页数:9
相关论文
共 63 条
[1]   Normal aging effects for frequency doubling technology perimetry [J].
Adams, CW ;
Bullimore, MA ;
Wall, M ;
Fingeret, M ;
Johnson, CA .
OPTOMETRY AND VISION SCIENCE, 1999, 76 (08) :582-587
[2]  
[Anonymous], 1997, Construction and assessment of classification rules
[3]   Short wavelength automated perimetry, frequency doubling technology perimetry, and pattern electroretinography for prediction of progressive glaucomatous standard visual field defects [J].
Bayer, AU ;
Erb, C .
OPHTHALMOLOGY, 2002, 109 (05) :1009-1017
[4]   New rapid threshold algorithm for short-wavelength automated perimetry [J].
Bengtsson, B .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (03) :1388-1394
[5]  
Bowd C, 2001, INVEST OPHTH VIS SCI, V42, P1993
[6]  
Breiman L, 1996, MACH LEARN, V24, P123, DOI 10.1007/BF00058655
[7]  
Brusini P, 1998, ACTA OPHTHALMOL SCAN, V76, P23
[8]   Comparison of frequency doubling perimetry with Humphrey visual field analysis in a glaucoma practice [J].
Burnstein, Y ;
Ellish, NJ ;
Magbalon, M ;
Higginbotham, EJ .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 129 (03) :328-333
[9]   Clinical comparison of frequency doubling technology perimetry and Humphrey perimetry [J].
Casson, R ;
James, B ;
Rubinstein, A ;
Ali, H .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (03) :360-362
[10]  
Chauhan BC, 1999, INVEST OPHTH VIS SCI, V40, P648