Orbital Floor Fractures Comparing Different Kinds of Reconstruction: A Proposal for Restoration of Physiological Anatomy

被引:3
作者
Spinzia, Alessia [1 ]
Renzetti, Paolo [2 ]
Bongiorno, Antonella [1 ]
Lagana, Francesco [1 ]
机构
[1] San Martino Polyclin Hosp, Sci Inst Hospitalizat & Treatment, Maxillofacial Surg Unit, Genoa, Italy
[2] San Martino Polyclin Hosp, Sci Inst Hospitalizat & Treatment, Neuroradiol Unit, Genoa, Italy
关键词
Blow out-fractures; orbital fractures; resorbable plate; titanium mesh; IMPLANT; REPAIR;
D O I
10.1097/SCS.0000000000006855
中图分类号
R61 [外科手术学];
学科分类号
摘要
The most effective treatment for orbital fractures is still under debate and different strategies are proposed in the literature. All such strategies focus on reconstruction of the orbital structure, neglecting the main function of the medial and inferior walls, these latter being constructed so as to break during high energy trauma. The aim of the authors is to highlight the difference between different reconstructive techniques in an orbital fracture restoration, being inclined to favor repair over reconstruction of the orbital floor, assuming that a second trauma could happen and reconstructive material left in the orbit may damage the visual apparatus in such a scenario. Following this theme, the authors propose a reconstruction strategy using a custom made stereolithographic model and resorbable plate made of polylactic acid mesh molded onto it. The mesh is used alone or in combination with bone graft, to obtain a better reparative result. At present, this approach is best suited to sports people and the young. Even if a deeper evaluation of the method would be useful, the series of case studies presented could be of stimulus for future discussion.
引用
收藏
页码:E128 / E134
页数:7
相关论文
共 23 条
[1]   A Protocol to Reduce Interobserver Variability in the Computed Tomography Measurement of Orbital Floor Fractures [J].
Ang, Chuan Han ;
Low, Jin Rong ;
Shen, Jia Yi ;
Cai, Elijah Zheng Yang ;
Hing, Eileen Chor Hoong ;
Chan, Yiong Huak ;
Sundar, Gangadhara ;
Lim, Thiam Chye .
CRANIOMAXILLOFACIAL TRAUMA & RECONSTRUCTION, 2015, 8 (04) :289-298
[2]   Reconstruction of orbital floor fracture with polyglactin 910/polydioxanon patch (Ethisorb):: A retrospective study [J].
Büchel, P ;
Rahal, A ;
Seto, C ;
Iizuka, T .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2005, 63 (05) :646-650
[3]   Late Complication Associated With the Treatment of Orbital Floor Fracture With Titanium Mesh [J].
Cavalcante Costa, Pedro Jorge ;
de Gauw, Johnny Holanda ;
Costa Filho, Jose Zenou ;
Moreira, Raphael Teixeira ;
Ribeiro Junior, Paulo Domingos .
JOURNAL OF CRANIOFACIAL SURGERY, 2018, 29 (06) :E623-E624
[4]   Lactosorb panel and screws for repair of large orbital floor defects [J].
Enislidis, G ;
Pichorner, S ;
Kainberger, F ;
Ewers, R .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 1997, 25 (06) :316-321
[5]   Finite element analysis of the human orbit. Behavior of titanium mesh for orbital floor reconstruction in case of trauma recurrence [J].
Foletti, J. M. ;
Martinez, V ;
Haen, P. ;
Godio-Raboutet, Y. ;
Guyot, L. ;
Thollon, L. .
JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2019, 120 (02) :91-94
[6]   Severe distortion of an orbital titanium mesh implant after recurrent facial trauma: a potential threat to the orbital contents? [J].
Foletti, J. M. ;
Scolozzi, P. .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2017, 55 (08) :836-838
[7]   Scleral Perforation Complicating Titanium Mesh Plaque in Orbital Blowout Fracture [J].
Koktekir, Bengu Ekinci ;
Bakbak, Berker ;
Karamese, Mehtap ;
Gedik, Sansal ;
Tosun, Zekeriya .
JOURNAL OF CRANIOFACIAL SURGERY, 2012, 23 (04) :964-965
[8]   The Role of Resorbable Plate and Artificial Bone Substitute in Reconstruction of Large Orbital Floor Defect [J].
Kwon, Ho ;
Kim, Ho Jun ;
Seo, Bommie F. ;
Jeong, Yeon Jin ;
Jung, Sung-No ;
Shim, Hyung-Sup .
BIOMED RESEARCH INTERNATIONAL, 2016, 2016
[9]   Orbital Adherence Syndrome Secondary to Titanium Implant Material [J].
Lee, Hui Bae Harold ;
Nunery, William R. .
OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2009, 25 (01) :33-36
[10]   CT-Based Morphological Analysis of Isolated Inferior and Medial Blow-out Orbital Fractures in Korean Adults [J].
Lee, Ji Eun ;
Lee, Jung Joo ;
Lee, Seung Uk ;
Nam, Ki Yup ;
Kwon, Jae Hwan ;
Park, Jin Hyung ;
Lee, Sang Joon .
ORBIT-AN INTERNATIONAL JOURNAL ON ORBITAL DISORDERS AND FACIAL RECONSTRUCTIVE SURGERY, 2015, 34 (06) :303-308