Techniques for Determining Cardiac Output in the Intensive Care Unit

被引:5
|
作者
Mohammed, Imran [1 ]
Phillips, Charles [1 ]
机构
[1] Oregon Hlth & Sci Univ, Div Pulm & Crit Care Med, Portland, OR 97201 USA
关键词
Cardiac output; Intensive care unit; Resuscitation; PULSE-CONTOUR ANALYSIS; PULMONARY-ARTERY CATHETERS; CRITICALLY-ILL PATIENTS; HEART-FAILURE; TRANSPULMONARY THERMODILUTION; IMPEDANCE CARDIOGRAPHY; DOPPLER; BEDSIDE; SYSTEM;
D O I
10.1016/j.ccc.2010.01.004
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
To achieve the goals of resuscitation in critically ill patients, a thorough understanding of the techniques available to measure cardiac output is important. Recently the pulmonary artery catheter has fallen out of favor because of concerns of safety and a lack of efficacy. Newer less invasive techniques since have been developed and are gaining popularity. But is important to remember that the ability of these techniques to improve outcome has yet to be demonstrated, and one should apply caution in how they are used until their use in algorithmic treatment approaches have been shown to improve outcome. This article discusses the invasive and noninvasive techniques to assess cardiac output.
引用
收藏
页码:355 / +
页数:12
相关论文
共 50 条
  • [1] PULSE CONTOUR CARDIAC-OUTPUT IN SURGICAL INTENSIVE-CARE UNIT PATIENTS
    TANNENBAUM, GA
    MATHEWS, D
    WEISSMAN, C
    JOURNAL OF CLINICAL ANESTHESIA, 1993, 5 (06) : 471 - 478
  • [2] Comparison of USCOM and PiCCO Cardiac Output Measurements in Intensive Care Unit
    Cakin, Ozlem
    Harmandar, Orbay
    Parlak, Hakan
    Cengiz, Melike
    Yilmaz, Murat
    Ramazanoglu, Atilla
    TURKISH JOURNAL OF INTENSIVE CARE-TURK YOGUN BAKIM DERGISI, 2024, 22 (03): : 212 - 217
  • [3] Noninvasive cardiac output monitoring in the pediatric cardiac intensive care unit
    Absi, Mohammed Ali
    Lutterman, Joel
    Wetzel, Glenn T.
    CURRENT OPINION IN CARDIOLOGY, 2010, 25 (02) : 77 - 79
  • [4] S The Role of Palliative Care in the Cardiac Intensive Care Unit
    Romano', Massimo
    HEALTHCARE, 2019, 7 (01)
  • [5] Minimally invasive monitoring of cardiac output in the cardiac surgery intensive care unit
    Alhashemi J.A.
    Cecconi M.
    Della Rocca G.
    Cannesson M.
    Hofer C.K.
    Current Heart Failure Reports, 2010, 7 (3) : 116 - 124
  • [6] Point-of-care blood testing and cardiac output measurement in the intensive care unit
    Shapiro, BA
    NEW HORIZONS-THE SCIENCE AND PRACTICE OF ACUTE MEDICINE, 1999, 7 (02): : 244 - 252
  • [7] Sepsis Management in the Cardiac Intensive Care Unit
    Zhang, Yichi
    McCurdy, Michael T.
    Ludmir, Jonathan
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2023, 10 (10)
  • [8] Noninvasive echocardiographic cardiac power output predicts mortality in cardiac intensive care unit patients
    Burstein, Barry
    Anand, Vidhu
    Ternus, Bradley
    Tabi, Meir
    Anavekar, Nandan S.
    Borlaug, Barry A.
    Barsness, Gregory W.
    Kane, Garvan C.
    Oh, Jae K.
    Jentzer, Jacob C.
    AMERICAN HEART JOURNAL, 2022, 245 : 149 - 159
  • [9] Errors of Commission in Cardiac Arrest Care in the Intensive Care Unit
    Gill, Harman Singh
    Lindgren, Elsa
    Steele, Alexander D.
    Chakraborti, Gouri
    Calhoun, Dylan A.
    Bharati, Pankaj
    Srikanth, Sathvik
    Nett, Sholeen T.
    Braga, Matthew S.
    JOURNAL OF INTENSIVE CARE MEDICINE, 2021, 36 (07) : 749 - 757
  • [10] A survey of cardiac output monitoring in intensive care units
    R Green
    J Craig
    B Kyle
    M Jonas
    Critical Care, 11 (Suppl 2):