Time-domain combination of MR spectroscopy data acquired using phased-array coils

被引:83
作者
Brown, MA [1 ]
机构
[1] Siemens Med Solut, Siemens Training & Dev Ctr, Cary, NC 27511 USA
关键词
MR spectroscopy; phased-array coils; data processing; time domain signal processing; spectral processing;
D O I
10.1002/mrm.20244
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A new method for efficiently processing MRS data acquired with phased-array coils is presented. The method consists of performing phase compensation (i.e., redefining the signal phase relative to a common reference) of the signals in the time domain prior to combining the signals. The resulting spectra are equivalent to those obtained by previously published methods for phased-array spectral data processing (i.e., processing the signals individually and then combining them in the frequency domain). The method allows spectra acquired with phased-array coils to be processed as efficiently as those acquired with non-phased-array coils. Both single voxel spectroscopy (SVS) and chemical shift imaging (CSI) data sets may be processed by this method. Magn Reson Med 52:1207-1213, 2004. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:1207 / 1213
页数:7
相关论文
共 10 条
[1]   AN NMR PHASED-ARRAY FOR HUMAN CARDIAC P-31 SPECTROSCOPY [J].
HARDY, CJ ;
BOTTOMLEY, PA ;
ROHLING, KW ;
ROEMER, PB .
MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (01) :54-64
[2]   NOISE CORRELATION [J].
JESMANOWICZ, A ;
HYDE, JS ;
FRONCISZ, W ;
KNEELAND, JB .
MAGNETIC RESONANCE IN MEDICINE, 1991, 20 (01) :36-47
[3]  
PROCK T, 2000, P ISMRM 8 ANN M, P562
[4]  
Pruessmann KP, 1999, MAGNET RESON MED, V42, P952, DOI 10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO
[5]  
2-S
[6]   Fast 1H spectroscopic imaging using a multi-element head-coil array [J].
Schäffter, T ;
Börnert, P ;
Leussler, C ;
Carlsen, IC ;
Leibfritz, D .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (02) :185-193
[7]   Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays [J].
Sodickson, DK ;
Manning, WJ .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (04) :591-603
[8]   PHASED-ARRAY DETECTORS AND AN AUTOMATED INTENSITY-CORRECTION ALGORITHM FOR HIGH-RESOLUTION MR-IMAGING OF THE HUMAN BRAIN [J].
WALD, LL ;
CARVAJAL, L ;
MOYHER, SE ;
NELSON, SJ ;
GRANT, PE ;
BARKOVICH, AJ ;
VIGNERON, DB .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (03) :433-439
[9]  
Wright SM, 1997, NMR BIOMED, V10, P394, DOI 10.1002/(SICI)1099-1492(199712)10:8<394::AID-NBM494>3.0.CO
[10]  
2-0