Seismic retrofitting of the historical masonry structures using numerical approach

被引:28
作者
Akcay, Cemil [1 ]
Bozkurt, Tank Serhat [2 ]
Sayin, Baris [1 ]
Yildizlar, Baris [1 ]
机构
[1] Istanbul Univ, Dept Civil Engn, Istanbul, Turkey
[2] Istanbul Tech Univ, Dept Architecture, Istanbul, Turkey
关键词
Historical structures; Restoration; Retrofitting; Numerical analysis; Lab test; HAGIA-SOPHIA; BELL-TOWER; VULNERABILITY; BEHAVIOR; CHURCH;
D O I
10.1016/j.conbuildmat.2016.03.121
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In historical buildings, because of the deterioration on structural members including slab and walls that complete their life cycle in time, due to environmental conditions; restoration applications have become necessary to increase the material durability level and to have adequate level of structural strength in order to resist dynamic effects such as earthquakes. This paper focuses on assessment of historical masonry structures from the point of seismic resistance. The entire process is illustrated using case study from a historical masonry structure. In this study conducted in this respect, a historical building is restored within the scope of laboratory studies and numerical analyses. The first stage of the study includes plaster analyses and mechanical tests conducted on the samples taken from the said building. In the second stage, i.e. numerical analysis, the building's existing 3D computer model was prepared and materials, members that are inadequate in terms of strength were determined. The third stage includes restoration applications by using laboratory and numerical analysis results. Within the scope of restoration applications, structural cracks on the walls were repaired using the injection method; volta slab (brick floor arches), exterior facade walls, interior walls and door/window gaps using different techniques were strengthened. In this study, it was aimed to increase material durability and structural strength by using conventional and modern techniques within the scope of laboratory tests and numerical approaches in recovering the historical buildings. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:752 / 763
页数:12
相关论文
共 30 条
[1]   Mechanical behavior of leaning masonry Huzhu Pagoda [J].
Abruzzese, Donato ;
Miccoli, Lorenzo ;
Yuan, Jianli .
JOURNAL OF CULTURAL HERITAGE, 2009, 10 (04) :480-486
[2]  
Ahunbay Z., 2004, CONSERVATION RESTORA, P134
[3]   Seismic evaluation and strengthening of nemrut monuments [J].
Aktas, Yasemin Didem ;
Turer, Ahmet .
JOURNAL OF CULTURAL HERITAGE, 2015, 16 (03) :381-385
[4]  
[Anonymous], 2007, TURK EARTHQ REG SPEC
[5]  
[Anonymous], 2003, C1531 ASTM INT
[6]  
[Anonymous], 1997, 498 TS
[7]   Seismic vulnerability assessment of historical masonry structural systems [J].
Asteris, P. G. ;
Chronopoulos, M. P. ;
Chrysostomou, C. Z. ;
Varum, H. ;
Plevris, V. ;
Kyriakides, N. ;
Silva, V. .
ENGINEERING STRUCTURES, 2014, 62-63 :118-134
[8]   Assessing the seismic vulnerability of a historical building [J].
Barbieri, Gaia ;
Biolzi, Luigi ;
Bocciarelli, Massimiliano ;
Fregonese, Luigi ;
Frigeri, Aronne .
ENGINEERING STRUCTURES, 2013, 57 :523-535
[9]   Strengthening and long-term monitoring of the structure of an historical church presbytery [J].
Bednarz, Lukasz J. ;
Jasienko, Jerzy ;
Rutkowski, Marcin ;
Nowak, Tomasz P. .
ENGINEERING STRUCTURES, 2014, 81 :62-75
[10]   Numerical modelling of the structural behaviour of Buti's bell tower [J].
Bernardeschi, K ;
Padovani, C ;
Pasquinelli, G .
JOURNAL OF CULTURAL HERITAGE, 2004, 5 (04) :371-378