Predictors of Clinical Outcome After Treatment of Intracranial Aneurysms with the Pipeline Embolization Device

被引:6
|
作者
Griffin, Andrew [1 ]
Reese, Vanessa [1 ]
Huseyinoglu, Zeynep [1 ]
Niedzwiecki, Donna [2 ]
Yang, Lexie [2 ]
Cutler, Andrew [1 ]
Gonzalez, L. Fernando [1 ]
Zomorodi, Ali [1 ]
Smith, Tony [1 ]
Hauck, Erik F. [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Neurosurg, Durham, NC 27710 USA
[2] Duke Univ, Med Ctr, Dept Biostat, Durham, NC USA
关键词
Aneurysm; Pipeline embolization device; Stent; CEREBRAL ANEURYSMS; MULTICENTER; COMPLICATIONS;
D O I
10.1016/j.wneu.2019.06.185
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: Flow-diverting stents have revolutionized the endovascular treatment of intracranial aneurysms. The purpose of this study is to identify predictors of adverse outcomes associated with the pipeline embolization device (PED). METHODS: A retrospective analysis of all patients treated with PED at a single high-volume center from January 2014 to September 2018. Patient outcomes, neurologic morbidity/mortality, and other clinical variables were analyzed. RESULTS: We treated 204 aneurysms in 170 patients with PED. Mean length of follow-up was 11 months. Most (181) aneurysms (89%) were located in the anterior circulation, and 23 (11%) were found in the posterior circulation. Most aneurysms were saccular (82%), followed by fusiform (11%), blister (4%), and dissecting pseudoaneurysms (3%). Mean aneurysm size was 8.2 + 5.7 mm with 145 (71%) small aneurysms (<= 10 mm), 53 (26%) large aneurysms (between 10 and 25 mm), and 6 (3%) giant aneurysms (>= 25 mm). Ninety-two percent of aneurysms were unruptured, and 8% were ruptured. The overall major neurologic morbidity/mortality was 4.7% and 1.8%, respectively. The all-cause mortality was 2.9%. Predictors of neurologic morbidity/mortality included the baseline modified Rankin Scale (P = 0.001), aneurysm neck size (P = 0.003), aneurysm size (P = 0.006), anterior versus posterior location (P = 0.02), and rupture at presentation (0.006). The P2Y12 Reactivity Unit, parent vessel diameter, and patient age did not correlate with adverse events. CONCLUSIONS: The PED has a satisfactory safety profile in both on- and off-label indications. A poor clinical patient baseline, wider aneurysm neck or larger size, and rupture predict an increased risk of an unfavorable outcome.
引用
收藏
页码:E666 / E671
页数:6
相关论文
共 50 条
  • [1] The Pipeline embolization device for treatment of intracranial aneurysms
    Eller, Jorge L.
    Dumont, Travis M.
    Sorkin, Grant C.
    Mokin, Maxim
    Levy, Elad I.
    Snyder, Kenneth V.
    Hopkins, L. Nelson
    Siddiqui, Adnan H.
    EXPERT REVIEW OF MEDICAL DEVICES, 2014, 11 (02) : 137 - 150
  • [2] Mortality after treatment of intracranial aneurysms with the Pipeline Embolization Device
    Kang, Huibin
    Luo, Bin
    Liu, Jianmin
    Zhang, Hongqi
    Li, Tianxiao
    Song, Donglei
    Zhao, Yuanli
    Guan, Sheng
    Maimaitili, Aisha
    Wang, Yunyan
    Feng, Wenfeng
    Wang, Yang
    Wan, Jieqing
    Mao, Guohua
    Shi, Huaizhang
    Wang, Kun
    Yang, Xinjian
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2022, 14 (01) : 46 - +
  • [3] Treatment of unruptured intracranial aneurysms with the pipeline embolization device
    Murthy, Santosh B.
    Shah, Shreyansh
    Rao, Chethan P. Venkatasubba
    Bershad, Eric M.
    Suarez, Jose I.
    JOURNAL OF CLINICAL NEUROSCIENCE, 2014, 21 (01) : 6 - 11
  • [4] Treatment of Ruptured Intracranial Aneurysms With the Pipeline Embolization Device
    Chalouhi, Nohra
    Zanaty, Mario
    Whiting, Alex
    Tjoumakaris, Stavropoula
    Hasan, David
    Ajiboye, Norman
    Hann, Shannon
    Rosenwasser, Robert H.
    Jabbour, Pascal
    NEUROSURGERY, 2015, 76 (02) : 165 - 172
  • [5] In-Stent Stenosis After Pipeline Embolization Device in Intracranial Aneurysms: Incidence, Predictors, and Clinical Outcomes
    Turhon, Mirzat
    Kang, Huibin
    Liu, Jian
    Zhang, Yisen
    Zhang, Ying
    Huang, Jiliang
    Wang, Kun
    Li, Mengxing
    Liu, Jianmin
    Zhang, Hongqi
    Li, Tianxiao
    Song, Donglei
    Zhao, Yuanli
    Luo, Bin
    Maimaiti, Aierpati
    Aisha, Maimaitili
    Wang, Yunyan
    Feng, Wenfeng
    Wang, Yang
    Wan, Jieqing
    Mao, Guohua
    Shi, Huaizhang
    Yang, Xinjian
    Guan, Sheng
    NEUROSURGERY, 2022, 91 (06) : 943 - 951
  • [6] Outcome study of the pipeline embolization device for treatment of intracranial aneurysms at a single UK institution
    Yang, Shih-Hung
    Hampton, Timothy
    Kandasamy, Naga
    Hart, Jonathan
    Ashmore, Jonathan
    Walsh, Daniel C.
    Tolias, Christos M.
    Booth, Thomas C.
    BRITISH JOURNAL OF NEUROSURGERY, 2017, 31 (06) : 661 - 667
  • [7] Treatment of recurrent intracranial aneurysms with the Pipeline Embolization Device
    Chalouhi, Nohra
    Chitale, Rohan
    Starke, Robert M.
    Jabbour, Pascal
    Tjoumakaris, Stavropoula
    Dumont, Aaron S.
    Rosenwasser, Robert H.
    Gonzalez, L. Fernando
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2014, 6 (01) : 19 - 23
  • [8] Use of Coils in Conjunction With the Pipeline Embolization Device for Treatment of Intracranial Aneurysms
    Lin, Ning
    Brouillard, Adam M.
    Krishna, Chandan
    Mokin, Maxim
    Natarajan, Sabareesh K.
    Sonig, Ashish
    Snyder, Kenneth V.
    Levy, Elad I.
    Siddiqui, Adnan H.
    NEUROSURGERY, 2015, 76 (02) : 142 - 149
  • [9] Current Status of Pipeline Embolization Device in the Treatment of Intracranial Aneurysms: A Review
    Tse, Mona M. Y.
    Yan, Bernard
    Dowling, Richard J.
    Mitchell, Peter J.
    WORLD NEUROSURGERY, 2013, 80 (06) : 829 - 835
  • [10] Pipeline Embolization Device for the Treatment of Unruptured Intracranial Dissecting Aneurysms
    Chen, Jigang
    Tao, Mushun
    Han, Jiangli
    Feng, Xin
    Peng, Fei
    Tong, Xin
    Niu, Hao
    Ma, Ning
    Liu, Aihua
    FRONTIERS IN NEUROLOGY, 2021, 12