Evaluation of False-Positive Reaction with ELISA for the Detection of Chlamydophila pneumoniae-Specific IgM Antibody in Adults

被引:0
|
作者
Miyashita, Naoyuki [1 ]
Kawai, Yasuhiro [2 ]
Yamaguchi, Tetsuya [2 ]
Ouchi, Kazunobu [2 ]
Kobashi, Yoshihiro [1 ]
Oka, Mikio [1 ]
机构
[1] Kawasaki Med Sch, Div Resp Dis, Dept Med, Kurashiki, Okayama 7010192, Japan
[2] Kawasaki Med Sch, Dept Pediat, Kurashiki, Okayama 7010192, Japan
关键词
D O I
暂无
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
引用
收藏
页码:150 / 151
页数:2
相关论文
共 50 条
  • [31] Potential False-Positive and False-Negative Results for COVID-19 IgG/IgM Antibody Testing After Heat-Inactivation
    Lin, Jie
    Dai, Wei
    Li, Weiwei
    Xiao, Li
    Luo, Tao
    Guo, Yanju
    Yang, Yang
    Han, Ying
    Zhu, Peiran
    Wu, Qiuyue
    He, Bangshun
    Wu, Jian
    Xia, Xinyi
    FRONTIERS IN MEDICINE, 2021, 7
  • [32] FALSE-POSITIVE ROSE-WAALER RHEUMATOID-FACTOR TITER GIVEN BY ANTI-RUMINANT IGM ANTIBODY
    JOHNSON, PM
    READING, CA
    HOLBOROW, EJ
    HOLDSTOCK, DJ
    VOX SANGUINIS, 1976, 31 (06) : 451 - 455
  • [33] Urea-mediated dissociation alleviate the false-positive Treponema pallidum-specific antibodies detected by ELISA
    Wang, Qiang
    Lei, Yan
    Lu, Xiaolan
    Wang, Guangrong
    Du, Qin
    Guo, Xiaolan
    Xing, Yan
    Zhang, Guoyuan
    Wang, Dongsheng
    PLOS ONE, 2019, 14 (03):
  • [34] INTERLABORATORY EVALUATION OF THE INDIRECT ELISA, THE ANTIBODY CAPTURE ELISA AND IMMUNOBLOTTING FOR THE DETECTION OF IGM ANTIBODIES TO TOXOPLASMA-GONDII
    HERBRINK, P
    VANLOON, AM
    ROTMANS, P
    VANKNAPEN, F
    VANDIJK, WC
    ANTONIE VAN LEEUWENHOEK JOURNAL OF MICROBIOLOGY, 1986, 52 (05): : 465 - 466
  • [35] DEMONSTRATION OF ELEVATED LEVELS OF CANDIDA-SPECIFIC IGM ANTIBODY IN A PATIENT WITH POSITIVE BLOOD CULTURE BY ELISA
    WASSMER, P
    ITIER, M
    SEVESTRE, H
    GASSER, M
    EXPERIENTIA, 1982, 38 (11): : 1375 - 1375
  • [36] False-positive results in ELISA-based anti FVIII antibody assay may occur with lupus anticoagulant and phospholipid antibodies
    Sahud, M.
    Zhukov, O.
    Mo, K.
    Popov, J.
    Dlott, J.
    HAEMOPHILIA, 2012, 18 (05) : 777 - 781
  • [37] An evaluation of the Xpert MTB/RIF assay and detection of false-positive rifampicin resistance in Mycobacterium tuberculosis
    Williamson, Deborah A.
    Basu, Indira
    Bower, James
    Freeman, Joshua T.
    Henderson, Gillian
    Roberts, Sally A.
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2012, 74 (02) : 207 - 209
  • [38] EVALUATION OF FALSE-POSITIVE BLOOD CULTURES - GUIDELINES FOR EARLY DETECTION OF CONTAMINATED CULTURES IN FEBRILE CHILDREN
    KORNBERG, AE
    JAIN, N
    DANNENHOFFER, R
    PEDIATRIC EMERGENCY CARE, 1994, 10 (01) : 20 - 22
  • [39] Automated detection of polyps with CT colonography:: Evaluation of volumetric features for reduction of false-positive findings
    Näppi, J
    Yoshida, H
    ACADEMIC RADIOLOGY, 2002, 9 (04) : 386 - 397
  • [40] Evaluation of MTANNs for eliminating false-positive with different computer aided pulmonary nodules detection software
    Shi, Zhenghao
    Ma, Jiejue
    Feng, Yaning
    He, Lifeng
    Suzuki, Kenji
    PAKISTAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2015, 28 (06) : 2311 - 2316