Analysis of Hemoglobin Glycation Using Microfluidic CE-MS: A Rapid, Mass Spectrometry Compatible Method for Assessing Diabetes Management

被引:36
作者
Redman, Erin A. [1 ]
Ramos-Payan, Maria [1 ]
Mellors, J. Scott [5 ]
Ramsey, J. Michael [1 ,2 ,3 ,4 ]
机构
[1] Univ N Carolina, Dept Chem, CB 3290, Chapel Hill, NC 27599 USA
[2] Univ N Carolina, Dept Appl Phys Sci, Chapel Hill, NC 27599 USA
[3] Univ N Carolina, Dept Biomed Engn, Chapel Hill, NC 27599 USA
[4] Univ N Carolina, Carolina Ctr Genome Sci, Chapel Hill, NC 27599 USA
[5] 908 Devices Inc, Boston, MA USA
基金
美国国家卫生研究院;
关键词
ELECTROPHORESIS-ELECTROSPRAY-IONIZATION; CAPILLARY-ELECTROPHORESIS; MICROCHIP; VARIANTS; ALBUMIN; BLOOD; SEPARATION; DEVICES; GLOBINS; PROTEIN;
D O I
10.1021/acs.analchem.6b00622
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Diabetes has become a significant health problem worldwide with the rate of diagnosis increasing rapidly in recent years. Measurement of glycated blood proteins, particularly glycated hemoglobin (HbA1c), is an important diagnostic tool used to detect and manage the condition in patients. Described here is a method using microfluidic capillary electrophoresis with mass spectrometry detection (CE-MS) to assess hemoglobin glycation in whole blood lysate. Using denaturing conditions, the hemoglobin (Hb) tetramer dissociates into the alpha and beta subunits (alpha- and beta-Hb), which are then separated via CE directly coupled to MS detection. Nearly baseline resolution is achieved between alpha-Hb, beta-Hb, and glycated beta-Hb. A second glycated beta-Hb isomer that is partially resolved from beta-Hb is detected in extracted ion electropherograms for glycated beta-Hb. Glycation on alpha-Hb is also detected in the alpha-Hb mass spectrum. Additional modifications to the beta-Hb are detected, including acetylation and a +57 Da species that could be the addition of a glyoxal moiety. Patient blood samples were analyzed using the microfluidic CE-MS method and a clinically used immunoassay to measure HbA1c. The percentage of glycated alpha-Hb and beta-Hb was calculated from the microfluidic CE-MS data using peak areas generated from extracted ion electropherograms. The values for glycated beta-Hb were found to correlate well with the HbA1c levels derived in the clinic, giving a slope of 1.20 and an R-2 value of 0.99 on a correlation plot. Glycation of human serum albumin (HSA) can also be measured using this technique. It was observed that patients with elevated glycated Hb levels also had higher levels of HSA glycation. Interestingly, the sample with the highest HbA1c levels did not have the highest levels of glycated HSA. Because the lifetime of HSA is shorter than Hb, this could indicate a recent lapse in glycemic control for that patient. The ability to assess both Hb and HSA glycation has the potential to provide a more complete picture of a patient's glycemic control in the months leading up to blood collection. The results presented here demonstrate that the microfluidic CE-MS method is capable of rapidly assessing Hb and HSA glycation from low volumes of whole blood with minimal sample preparation and has the potential to provide more information in a single analysis step than current technologies.
引用
收藏
页码:5324 / 5330
页数:7
相关论文
共 52 条
[1]   Structural alterations of hemoglobin and myoglobin by glyoxal: A comparative study [J].
Banerjee, Sauradipta ;
Chakraborti, Abhay Sankar .
INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2014, 66 :311-318
[2]   Chemical Vapor Deposition of Aminopropyl Si lanes in Microfluidic Channels for Highly Efficient Microchip Capillary Electrophoresis-Electrospray Ionization-Mass Spectrometry [J].
Batz, Nicholas G. ;
Mellors, J. Scott ;
Alarie, Jean Pierre ;
Ramsey, J. Michael .
ANALYTICAL CHEMISTRY, 2014, 86 (07) :3493-3500
[3]   Utilizing Microchip Capillary Electrophoresis Electrospray Ionization for Hydrogen Exchange Mass Spectrometry [J].
Black, William A. ;
Stocks, Bradley B. ;
Mellors, J. Scott ;
Engen, John R. ;
Ramsey, J. Michael .
ANALYTICAL CHEMISTRY, 2015, 87 (12) :6280-6287
[4]   Continuous flow reaction monitoring using an on-line miniature mass spectrometer [J].
Browne, Duncan L. ;
Wright, Steven ;
Deadman, Benjamin J. ;
Dunnage, Samantha ;
Baxendale, Ian R. ;
Turner, Richard M. ;
Ley, Steven V. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2012, 26 (17) :1999-2010
[5]  
Bry L, 2001, CLIN CHEM, V47, P153
[6]   Evaluation of a compact mass spectrometer for routine support of pharmaceutical chemistry [J].
Bu, Xiaodong ;
Yang, Jiong ;
Gong, Xiaoyi ;
Welch, Christopher J. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 94 :139-144
[7]   Analysis of peptides, proteins, protein digests, and whole human blood by capillary electrophoresis electrospray ionization mass spectrometry using an in-capillary electrode sheathless interface [J].
Cao, P ;
Moini, M .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1998, 9 (10) :1081-1088
[8]   Separation and detection of the α- and β-chains of hemoglobin of a single intact red blood cell using capillary electrophoresis/electrospray ionization time-of-flight mass spectrometry [J].
Cao, P ;
Moini, M .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (02) :184-186
[9]   Microchip devices for high-efficiency separations [J].
Culbertson, CT ;
Jacobson, SC ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 2000, 72 (23) :5814-5819
[10]   Dispersion sources for compact geometries on microchips [J].
Culbertson, CT ;
Jacobson, SC ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 1998, 70 (18) :3781-3789