Backside wear, particle migration and effectiveness of screw hole plugs in acetabular hip joint replacement with cross-linked polyethylene

被引:12
作者
Braun, Steffen [1 ]
Vardag, Shirin [1 ]
Mueller, Ulrike [1 ]
Schroeder, Stefan [1 ]
Sonntag, Robert [1 ]
Bormann, Therese [1 ]
Gotterbarm, Tobias [2 ]
Kretzer, Jan Philippe [1 ]
机构
[1] Heidelberg Univ Hosp, Clin Orthoped & Trauma Surg, Lab Biomech & Implant Res, Schlierbacher Landstr 200a, D-69118 Heidelberg, Germany
[2] Kepler Univ Hosp, Dept Orthoped, Krankenhausstr 9, A-4021 Linz, Austria
关键词
Total hip replacement; Hip cup system; Backside wear; Particle migration; Screw hole plugs; PERIPROSTHETIC OSTEOLYSIS; CONVENTIONAL POLYETHYLENE; FOLLOW-UP; ARTHROPLASTY; COMPONENTS; SIMULATION; DEBRIS; LINERS; FLUID; RATES;
D O I
10.1016/j.actbio.2019.07.050
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In total hip arthroplasty, osteolysis of the acetabulum often occurs at the backside of cups in the area of screw holes, indicating a clinically relevant amount of polyethylene (PE) wear particles in this area. In order to avoid a possible migration of wear particles to the acetabulum-bone, screw hole plugs are provided for some implant systems. The aims of this study were to quantitatively determine backside wear and to investigate the migration behaviour of articulation-related wear particles in a cup system with open and closed screw holes by plugs. Titanium cup systems with backside holes for screw fixations were sinusoidally loaded with 2.7 kN. The articulation area was separated from the backside area of the cup. A defined amount of articulation generated particles was added to the fluid of the articulation chamber. The fluids in the two chambers were separately filtered after 2 x 10(6) cycles for a particle analysis. Backside wear with noticeably small (65.6 +/- 4.2 nm) and round PE particles was identified. With both open and closed screw holes, a migration of the articulating wear particles from the articulation area behind the cup could be observed. Backside wear was estimated to be below 1% of the articulated wear. Screw hole plugs did not effectively prevent the migration of PE wear particles behind the investigated cups. Statement of Significance Backside wear occurs in a proven cup-system. Furthermore, it was quantitatively observed that articulation-generated wear products could migrate from the articulating area along the cup/liner-interface through the screw holes behind the cup. An almost unimpeded particle migration to the acetabulum-bone, in conjunction with very small backside wear particles, could produce a clinically relevant amount of PE with respect to pelvic lysis. These findings highlight the importance of management to avoid particle migration in artificial hip cups. Therefore, primarily the use of screw hole plugs, as far as available for the respective cup-system, is recommended. The aim of avoiding particle migration by plugs, but also by using a sophisticated anchoring mechanism between cup and PE liner should continue in future. (C) 2019 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:239 / 246
页数:8
相关论文
共 44 条
[1]   Wear performance of neat and vitamin E blended highly cross-linked PE under severe conditions: The combined effect of accelerated ageing and third body particles during wear test [J].
Affatato, Saverio ;
De Mattia, Jonathan Salvatore ;
Bracco, Pierangiola ;
Pavoni, Eleonora ;
Taddei, Paola .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2016, 64 :240-252
[2]   Minimal Backside Surface Changes Observed in Retrieved Acetabular Liners [J].
Akbari, Abtin ;
Roy, Marcel E. ;
Whiteside, Leo A. ;
Katerberg, Brian J. ;
Schnettgoecke, Daniel J. .
JOURNAL OF ARTHROPLASTY, 2011, 26 (05) :686-692
[3]   Periprosthetic wear particle migration and distribution modelling and the implication for osteolysis in cementless total hip replacement [J].
Alidousti, Hamidreza ;
Taylor, Mark ;
Bressloff, Neil W. .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2014, 32 :225-244
[4]  
[Anonymous], 2010, F187716 ASTM
[5]  
[Anonymous], 142422 ISO
[6]  
Bali K., 2015, CLIN ORTHOP RELAT RE
[7]   Backside wear in acetabular hip joint replacement [J].
Braun, Steffen ;
Sonntag, Robert ;
Schroeder, Stefan ;
Mueller, Ulrike ;
Jaeger, Sebastian ;
Gotterbarm, Tobias ;
Kretzer, Jan Philippe .
ACTA BIOMATERIALIA, 2019, 83 :467-476
[8]  
BUECHEL FF, 1994, CLIN ORTHOP RELAT R, P202
[9]   Extensive Osteolysis Caused By Polyethylene Particle Migration in an Anatomical Hydroxyapatite-Coated Hip Prosthesis: 10 Years' Follow-Up [J].
Canales, Vicente ;
Panisello, Juan J. ;
Herrera, Antonio ;
Sola, Alejandro ;
Mateo, Jesus J. ;
Caballero, Maria J. .
JOURNAL OF ARTHROPLASTY, 2010, 25 (07) :1115-1124
[10]   Size, shape, and composition of wear particles from metal-metal hip simulator testing: Effects of alloy and number of loading cycles [J].
Catelas, I ;
Bobyn, JD ;
Medley, JB ;
Krygier, JJ ;
Zukor, DJ ;
Huk, OL .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2003, 67A (01) :312-327