A dual image approach for bias field correction in magnetic resonance imaging

被引:19
作者
Lai, SH [1 ]
Fang, M
机构
[1] Natl Tsing Hua Univ, Dept Comp Sci, Hsinchu 300, Taiwan
[2] Siemens Corp Res, Princeton, NJ 08540 USA
关键词
intensity inhomogeneity correction; medical image restoration; image fusion; spline surface fitting; magnetic resonance imaging;
D O I
10.1016/S0730-725X(02)00637-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this paper, we propose a dual image approach to correcting intensity inhomogeneities for MR images acquired using surface coils. Previous methods are usually not satisfactory due to restricted application domains, considerable human interactions, or some undesirable artifacts. The proposed algorithm provides nice correction results for a variety of surface-coil MR images. It is accomplished by using an additional body-coil MR image of a smaller size captured at the same position as that of the surface-coil image to facilitate the estimation of the bias field function. The correction algorithm consists of aligning the surface-coil image with the body-coil image and fitting a spline surface from a sparse set of data points for the associated bias field function. Experiments on some real images show satisfactory correction results by using the proposed algorithm. (C) 2003 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:121 / 125
页数:5
相关论文
共 11 条
[1]   IMAGE NONUNIFORMITY IN MAGNETIC-RESONANCE-IMAGING - ITS MAGNITUDE AND METHODS FOR ITS CORRECTION [J].
CONDON, BR ;
PATTERSON, J ;
WYPER, D ;
JENKINS, PA ;
HADLEY, DM .
BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (709) :83-87
[2]   CORRECTION OF INTENSITY VARIATIONS IN MR-IMAGES FOR COMPUTER-AIDED TISSUE CLASSIFICATION [J].
DAWANT, BM ;
ZIJDENBOS, AP ;
MARGOLIN, RA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (04) :770-781
[3]  
Dennis, 1996, NUMERICAL METHODS UN
[4]  
Golub G. H., 2013, Matrix Computations
[5]   Segmentation of multiple sclerosis lesions in intensity corrected multispectral MRI [J].
Johnston, B ;
Atkins, MS ;
Mackiewich, B ;
Anderson, M .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (02) :154-169
[6]  
Lai S H, 1999, Med Image Anal, V3, P409, DOI 10.1016/S1361-8415(99)80033-4
[7]   Reliable and efficient computation of optical flow [J].
Lai, SH ;
Vemuri, BC .
INTERNATIONAL JOURNAL OF COMPUTER VISION, 1998, 29 (02) :87-105
[8]   RETROSPECTIVE CORRECTION OF INTENSITY INHOMOGENEITIES IN MRI [J].
MEYER, CR ;
BLAND, PH ;
PIPE, J .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1995, 14 (01) :36-41
[9]  
Shang-Hong Lai, 1999, Proceedings. 1999 IEEE Computer Society Conference on Computer Vision and Pattern Recognition (Cat. No PR00149), P167, DOI 10.1109/CVPR.1999.784625
[10]   POLYNOMIAL MODELING AND REDUCTION OF RF BODY COIL SPATIAL INHOMOGENEITY IN MRI [J].
TINCHER, M ;
MEYER, CR ;
GUPTA, R ;
WILLIAMS, DM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (02) :361-365