Hierarchical Template Matching for 3D Myocardial Tracking and Cardiac Strain Estimation

被引:2
作者
Bhalodiya, Jayendra M. [1 ]
Palit, Arnab [1 ]
Ferrante, Enzo [2 ]
Tiwari, Manoj K. [3 ]
Bhudia, Sunil K. [4 ]
Arvanitis, Theodoros N. [5 ]
Williams, Mark A. [1 ]
机构
[1] Univ Warwick, WMG, Coventry CV4 7AL, W Midlands, England
[2] UNL, CONICET, Inst Invest Senales Sistemas & Inteligencia Compu, Sinc I,FICH, Santa Fe, Argentina
[3] Indian Inst Technol Kharagpur, Kharagpur 721302, W Bengal, India
[4] Royal Brompton & Harefield NHS Fdn Trust, London SW3 6NP, England
[5] Univ Warwick, WMG, Inst Digital Healthcare, Warwick CV4 7AL, England
基金
英国惠康基金; 英国经济与社会研究理事会; 英国工程与自然科学研究理事会; 英国医学研究理事会;
关键词
HUMAN LEFT-VENTRICLE; IMAGE REGISTRATION; MOTION; MRI; PATTERNS; HEART;
D O I
10.1038/s41598-019-48927-2
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Myocardial tracking and strain estimation can non-invasively assess cardiac functioning using subject-specific MRI. As the left-ventricle does not have a uniform shape and functioning from base to apex, the development of 3D MRI has provided opportunities for simultaneous 3D tracking, and 3D strain estimation. We have extended a Local Weighted Mean (LWM) transformation function for 3D, and incorporated in a Hierarchical Template Matching model to solve 3D myocardial tracking and strain estimation problem. The LWM does not need to solve a large system of equations, provides smooth displacement of myocardial points, and adapt local geometric differences in images. Hence, 3D myocardial tracking can be performed with 1.49 mm median error, and without large error outliers. The maximum error of tracking is up to 24% reduced compared to benchmark methods. Moreover, the estimated strain can be insightful to improve 3D imaging protocols, and the computer code of LWM could also be useful for geo-spatial and manufacturing image analysis researchers.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Multiview diffeomorphic registration: Application to motion and strain estimation from 3D echocardiography
    Piella, Gemma
    De Craene, Mathieu
    Butakoff, Constantine
    Grau, Vicente
    Yao, Cheng
    Nedjati-Gilani, Shahrum
    Penney, Graeme P.
    Frangi, Alejandro F.
    [J]. MEDICAL IMAGE ANALYSIS, 2013, 17 (03) : 348 - 364
  • [32] Left Ventricular Strain Examination of Different Aged Adults with 3D Speckle Tracking Echocardiography
    Xia, Ji-zhu
    Xia, Ji-yi
    Li, Gang
    Ma, Wen-yan
    Wang, Qing-qing
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2014, 31 (03): : 335 - 339
  • [33] A 3D Template Model for Healthy and Impaired Walking
    Sharbafi, Maziar A.
    Zadravec, Matjaz
    Matjacic, Zlatko
    Seyfarth, Andre
    [J]. 2018 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS), 2018, : 1218 - 1225
  • [34] Phase contrast MRI of myocardial 3D strain by encoding contiguous slices in a single shot
    Reese, TG
    Feinberg, DA
    Dou, JG
    Wedeen, VJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (04) : 665 - 676
  • [35] Probabilistic Sparse Matching for Robust 3D/3D Fusion in Minimally Invasive Surgery
    Neumann, Dominik
    Grbic, Sasa
    John, Matthias
    Navab, Nassir
    Hornegger, Joachim
    Ionasec, Razvan
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (01) : 49 - 60
  • [36] Comparison of cardiac MRI tissue tracking and myocardial tagging for assessment of regional ventricular strain
    Harrild, David M.
    Han, Yuchi
    Geva, Tal
    Zhou, Jing
    Marcus, Edward
    Powell, Andrew J.
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (08) : 2009 - 2018
  • [37] Extending 3D Lucas-Kanade tracking with adaptive templates for head pose estimation
    Chen, Zhih-Wei
    Chiang, Cheng-Chin
    Hsieh, Zi-Tian
    [J]. MACHINE VISION AND APPLICATIONS, 2010, 21 (06) : 889 - 903
  • [38] 3D motion tracking by Kalman filtering
    Gao, J
    Kosaka, A
    Kak, A
    [J]. INTERNET MULTIMEDIA MANAGEMENT SYSTEMS, 2000, 4210 : 162 - 170
  • [39] Fast and Robust 3D Correspondence Matching and Its Application to Volume Registration
    Tajima, Yuichiro
    Fudano, Kinya
    Ito, Koichi
    Aoki, Takafumi
    [J]. IEICE TRANSACTIONS ON INFORMATION AND SYSTEMS, 2013, E96D (04): : 826 - 835
  • [40] A 3D point matching algorithm for affine registration
    Jianqin Qu
    Leiguang Gong
    Lin Yang
    [J]. International Journal of Computer Assisted Radiology and Surgery, 2011, 6 : 229 - 236