Impact of metallic dental implants on CT-based attenuation correction in a combined PET/CT scanner

被引:130
作者
Kamel, EM [1 ]
Burger, C [1 ]
Buck, A [1 ]
von Schulthess, GK [1 ]
Goerres, GW [1 ]
机构
[1] Univ Zurich Hosp, Div Nucl Med, CH-8091 Zurich, Switzerland
关键词
PET; CT; attenuation correction; artifacts;
D O I
10.1007/s00330-002-1564-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Our objective was to study the effect of metal-induced artifacts on the accuracy of the CT-based anatomic map as a prerequisite for attenuation correction of the positron emission tomography (PET) emission data. Twenty-seven oncology patients with dental metalwork were enrolled in the present study. Data acquisition was performed on a PET/CT in-line system (Discovery LS, GE Medical Systems, Milwaukee, Wis.). Attenuation correction of emission data was done twice, using an 80-mA CT scan (PETCT80) and a Ge-68 transmission scan (PET68Ge)Average count in kBq/cc was measured in regions with and without artifacts and compared for PETCT80 and PET68Ge. Data analysis of region of interests (ROIs) revealed that the ratio (ROIs PETCT80/ROIs PET68Ge) and the difference (ROIs PETCT80 minus ROIs PET68Ge) had a higher mean of values in regions with artifacts than in regions without artifacts (1.2 +/- 0.17 vs 1.06 +/- 0.06 and 0.68 +/- 0.67 vs 0.15 +/- 0.17 kBq/cc, respectively). For most of the studied artifactual ROIs, the PETCT80 values were higher than those of the PET68Ge. Attenuation correction of PET emission data using an artifactual CT map yields false values in regions nearby artifacts caused by dental metalwork. This may falsely estimate PET quantitative studies and may disturb the visual interpretation of PET scan.
引用
收藏
页码:724 / 728
页数:5
相关论文
共 50 条
[31]   A combined PET/CT scanner for clinical oncology [J].
Beyer, T ;
Townsend, DW ;
Brun, T ;
Kinahan, PE ;
Charron, M ;
Roddy, R ;
Jerin, J ;
Young, J ;
Byars, L ;
Nutt, R .
JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (08) :1369-1379
[32]   Interpolated average CT for cardiac PET/CT attenuation correction [J].
Mok, Greta S. P. ;
Ho, Cobie Y. T. ;
Yang, Bang-Hung ;
Wu, Tung-Hsin .
JOURNAL OF NUCLEAR CARDIOLOGY, 2016, 23 (05) :1072-1079
[33]   Interpolated average CT for PET attenuation correction in different lesion characteristics [J].
Ho, Cobie Y. T. ;
Wu, Tung-Hsin ;
Mok, Greta S. P. .
NUCLEAR MEDICINE COMMUNICATIONS, 2016, 37 (03) :297-306
[34]   Impact of CT attenuation correction on viable myocardium detection in combined SPECT and PET/CT: A retrospective cohort study [J].
Zhao, Fukai ;
Chen, Yue ;
Zhao, Jiaming ;
Pang, Zekun ;
Wang, Jiao ;
Cao, Bing ;
Li, Jianming .
MEDICINE, 2024, 103 (43) :e40175
[35]   CT-based Evaluation of Segmented Head Regions for Attenuation Correction in MR-PET Systems [J].
Wagenknecht, Gudrun ;
Kops, Elena Rota ;
Kaffanke, Joachim ;
Tellmann, Lutz ;
Mottaghy, Felix ;
Piroth, Marc D. ;
Herzog, Hans .
2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, :2793-2797
[36]   Impact of CT-Based and MRI-Based Attenuation Correction Methods on 18 F-FDG PET Quantification Using PET Phantoms [J].
Cheng-Han Wu ;
Chun-Yuan Tu ;
Li-Chen Shen ;
Yueh-Hsun Lu ;
Bang-Hung Yang .
Journal of Medical and Biological Engineering, 2022, 42 :374-381
[37]   Preclinical Evaluation of MR Attenuation Correction Versus CT Attenuation Correction on a Sequential Whole-Body MR/PET Scanner [J].
Bini, Jason ;
Izquierdo-Garcia, David ;
Mateo, Jesus ;
Machac, Josef ;
Narula, Jagat ;
Fuster, Valentin ;
Fayad, Zahi A. .
INVESTIGATIVE RADIOLOGY, 2013, 48 (05) :313-322
[38]   Improving CT-Based PET Attenuation Correction in the Vicinity of Metal Implants by an Iterative Metal Artifact Reduction Algorithm of CT Data and Its Comparison to Dual-Energy-Based Strategies A Phantom Study [J].
Schabel, Christoph ;
Gatidis, Sergios ;
Bongers, Malte ;
Huettig, Fabian ;
Bier, Georg ;
Kupferschlaeger, Juergen ;
Bamberg, Fabian ;
la Fougere, Christian ;
Nikolaou, Konstantin ;
Pfannenberg, Christina .
INVESTIGATIVE RADIOLOGY, 2017, 52 (01) :61-65
[39]   Head and neck imaging with PET and PET/CT: artefacts from dental metallic implants [J].
Goerres, GW ;
Hany, TF ;
Kamel, E ;
von Schulthess, GK ;
Buck, A .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (03) :367-370
[40]   CT-based attenuation and scatter correction compared with uniform attenuation correction in brain perfusion SPECT imaging for dementia [J].
Gillen, Rebecca ;
Firbank, Michael J. ;
Lloyd, Jim ;
O'Brien, John T. .
PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (17) :6775-6787