Impact of metallic dental implants on CT-based attenuation correction in a combined PET/CT scanner

被引:129
作者
Kamel, EM [1 ]
Burger, C [1 ]
Buck, A [1 ]
von Schulthess, GK [1 ]
Goerres, GW [1 ]
机构
[1] Univ Zurich Hosp, Div Nucl Med, CH-8091 Zurich, Switzerland
关键词
PET; CT; attenuation correction; artifacts;
D O I
10.1007/s00330-002-1564-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Our objective was to study the effect of metal-induced artifacts on the accuracy of the CT-based anatomic map as a prerequisite for attenuation correction of the positron emission tomography (PET) emission data. Twenty-seven oncology patients with dental metalwork were enrolled in the present study. Data acquisition was performed on a PET/CT in-line system (Discovery LS, GE Medical Systems, Milwaukee, Wis.). Attenuation correction of emission data was done twice, using an 80-mA CT scan (PETCT80) and a Ge-68 transmission scan (PET68Ge)Average count in kBq/cc was measured in regions with and without artifacts and compared for PETCT80 and PET68Ge. Data analysis of region of interests (ROIs) revealed that the ratio (ROIs PETCT80/ROIs PET68Ge) and the difference (ROIs PETCT80 minus ROIs PET68Ge) had a higher mean of values in regions with artifacts than in regions without artifacts (1.2 +/- 0.17 vs 1.06 +/- 0.06 and 0.68 +/- 0.67 vs 0.15 +/- 0.17 kBq/cc, respectively). For most of the studied artifactual ROIs, the PETCT80 values were higher than those of the PET68Ge. Attenuation correction of PET emission data using an artifactual CT map yields false values in regions nearby artifacts caused by dental metalwork. This may falsely estimate PET quantitative studies and may disturb the visual interpretation of PET scan.
引用
收藏
页码:724 / 728
页数:5
相关论文
共 50 条
[21]   Effects of CT-based attenuation correction on quantitative SPECT/CT of jawbone [J].
Tsuchitani, Tatsuya ;
Kitajima, Kazuhiro ;
Takahashi, Yoshiyuki ;
Yoshida, Rika ;
Kiada, Hayato ;
Tsurusaki, Masakatsu ;
Minami, Tetsuya ;
Kotura, Noriko .
HELLENIC JOURNAL OF NUCLEAR MEDICINE, 2023, 26 (02) :108-113
[22]   Sinogram-based attenuation correction in PET/CT [J].
Yang, Qingsong ;
Lu, Yang ;
Xi, Yan ;
Cong, Wenxiang ;
Kalra, Mannudeep ;
Wang, Ge .
JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2016, 24 (01) :9-22
[23]   Comparative Assessment of Energy-Mapping Approaches in CT-Based Attenuation Correction for PET [J].
Mohammad R. Ay ;
Maryam Shirmohammad ;
Saeed Sarkar ;
Arman Rahmim ;
Habib Zaidi .
Molecular Imaging and Biology, 2011, 13 :187-198
[24]   MR-based attenuation correction for cardiac FDG PET on a hybrid PET/MRI scanner: comparison with standard CT attenuation correction [J].
Jan Vontobel ;
Riccardo Liga ;
Mathias Possner ;
Olivier F. Clerc ;
Fran Mikulicic ;
Patrick Veit-Haibach ;
Edwin E. G. W. ter Voert ;
Tobias A. Fuchs ;
Julia Stehli ;
Aju P. Pazhenkottil ;
Dominik C. Benz ;
Christoph Gräni ;
Oliver Gaemperli ;
Bernhard Herzog ;
Ronny R. Buechel ;
Philipp A. Kaufmann .
European Journal of Nuclear Medicine and Molecular Imaging, 2015, 42 :1574-1580
[25]   MR-based attenuation correction for cardiac FDG PET on a hybrid PET/MRI scanner: comparison with standard CT attenuation correction [J].
Vontobel, Jan ;
Liga, Riccardo ;
Possner, Mathias ;
Clerc, Olivier F. ;
Mikulicic, Fran ;
Veit-Haibach, Patrick ;
ter Voert, Edwin E. G. W. ;
Fuchs, Tobias A. ;
Stehli, Julia ;
Pazhenkottil, Aju P. ;
Benz, Dominik C. ;
Graeni, Christoph ;
Gaemperli, Oliver ;
Herzog, Bernhard ;
Buechel, Ronny R. ;
Kaufmann, Philipp A. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 (10) :1574-1580
[26]   Comparison template-based with CT-based attenuation correction for hybrid MR/PET scanners [J].
Elena Rota Kops ;
Hans Herzog ;
N Jon Shah .
EJNMMI Physics, 1 (Suppl 1)
[27]   Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging [J].
David Izquierdo-Garcia ;
Stephen J. Sawiak ;
Karin Knesaurek ;
Jagat Narula ;
Valentin Fuster ;
Joseph Machac ;
Zahi A. Fayad .
European Journal of Nuclear Medicine and Molecular Imaging, 2014, 41 :1574-1584
[28]   Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging [J].
Izquierdo-Garcia, David ;
Sawiak, Stephen J. ;
Knesaurek, Karin ;
Narula, Jagat ;
Fuster, Valentin ;
Machac, Joseph ;
Fayad, Zahi A. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 (08) :1574-1584
[29]   Reduction of Intravenous Contrast Related Artifacts in CT-Based Attenuation Corrected PET Images [J].
Ay, M. R. ;
Bidgholi, J. H. ;
Ghafarian, P. ;
Zaidi, H. .
4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3) :513-516
[30]   A combined PET/CT scanner for clinical oncology [J].
Beyer, T ;
Townsend, DW ;
Brun, T ;
Kinahan, PE ;
Charron, M ;
Roddy, R ;
Jerin, J ;
Young, J ;
Byars, L ;
Nutt, R .
JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (08) :1369-1379