Application safety evaluation of the radio frequency identification tag under magnetic resonance imaging

被引:4
作者
Fei, Xiaolu [1 ]
Li, Shanshan [1 ]
Gao, Shan [1 ]
Wei, Lan [1 ]
Wang, Lihong [2 ]
机构
[1] Capital Med Univ, Xuanwu Hosp, Dept Informat Technol, Beijing 100053, Peoples R China
[2] Capital Med Univ, Xuanwu Hosp, Informat Management Off, Beijing 100053, Peoples R China
关键词
RFID tags; MRI sequence; Electromagnetic interference; Imaging quality;
D O I
10.1186/1475-925X-13-129
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Radio Frequency Identification(RFID) has been widely used in healthcare facilities, but it has been paid little attention whether RFID applications are safe enough under healthcare environment. The purpose of this study is to assess the effects of RFID tags on Magnetic Resonance (MR) imaging in a typical electromagnetic environment in hospitals, and to evaluate the safety of their applications. Methods: A Magphan phantom was used to simulate the imaging objects, while active RFID tags were placed at different distances (0, 4, 8, 10 cm) from the phantom border. The phantom was scanned by using three typical sequences including spin-echo (SE) sequence, gradient-echo (GRE) sequence and inversion-recovery (IR) sequence. The quality of the image was quantitatively evaluated by using signal-to-noise ratio (SNR), uniformity, high-contrast resolution, and geometric distortion. RFID tags were read by an RFID reader to calculate their usable rate. Results: RFID tags can be read properly after being placed in high magnetic field for up to 30 minutes. SNR: There were no differences between the group with RFID tags and the group without RFID tags using SE and IR sequence, but it was lower when using GRE sequence. Uniformity: There was a significant difference between the group with RFID tags and the group without RFID tags using SE and GRE sequence. Geometric distortion and high-contrast resolution: There were no obvious differences found. Conclusions: Active RFID tags can affect MR imaging quality, especially using the GRE sequence. Increasing the distance from the RFID tags to the imaging objects can reduce that influence. When the distance was longer than 8 cm, MR imaging quality were almost unaffected. However, the Gradient Echo related sequence is not recommended when patients wear a RFID wristband.
引用
收藏
页数:13
相关论文
共 16 条
[1]   Principles, Techniques, and Applications of T2*-based MR Imaging and Its Special Applications [J].
Chavhan, Govind B. ;
Babyn, Paul S. ;
Thomas, Bejoy ;
Shroff, Manohar M. ;
Haacke, E. Mark .
RADIOGRAPHICS, 2009, 29 (05) :1433-U272
[2]  
Christe B, 2008, BIOMED INSTRUM TECHN, V12, P479
[3]  
Haacke E.M., 1999, Magnetic Resonance Imaging: Physical Principles and Sequence Design
[4]   Straight from the shoulder [J].
Halamka, J .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 353 (04) :331-333
[5]   The security implications of VeriChip cloning [J].
Halamka, John ;
Juels, Ari ;
Stubblefield, Adam ;
Westhues, Jonathan .
JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 2006, 13 (06) :601-607
[6]  
HARROP P, RFID HEALTHCARE PHAR
[7]  
Iadanza E, 2010, ELECTROMAGNETIC INTE
[8]  
Interference E, 1996, HLTH DEVICES, V25, P263
[9]   A Call for Safer Utilization of Radio Frequency Identification in the e-Health Era [J].
Liu, Chung-Feng ;
Hwang, Hsin-Ginn ;
Kuo, Kuang-Ming ;
Hung, Won-Fu .
TELEMEDICINE AND E-HEALTH, 2011, 17 (08) :615-619
[10]   Multidimensional evaluation of a radio frequency identification wi-fi location tracking system in an acute-care hospital setting [J].
Okoniewska, Barbara ;
Graham, Alecia ;
Gavrilova, Marina ;
Wah, Dannel ;
Gilgen, Jonathan ;
Coke, Jason ;
Burden, Jack ;
Nayyar, Shikha ;
Kaunda, Joseph ;
Yergens, Dean ;
Baylis, Barry ;
Ghali, William A. .
JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 2012, 19 (04) :674-679