3-D real-time motion correction in high-intensity focused ultrasound therapy

被引:96
作者
Pernot, M [1 ]
Tanter, M [1 ]
Fink, M [1 ]
机构
[1] Univ Paris 07, ESPCI, Lab Ondes & Acoust, CNRS,UMR 7587, F-75005 Paris, France
关键词
HIFU; focused ultrasound; therapy; motion tracking;
D O I
10.1016/j.ultrasmedbio.2004.07.021
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A method for tracking the 3-D motion of tissues in real-time is combined with a 2-D high-intensity focused ultrasound (US), or HIFU, multichannel system to correct for respiratory motion during HIFU therapy. Motion estimation is based on an accurate ultrasonic speckle-tracking method. A pulse-echo sequence is performed for a subset of the transducers of the phased array. For each of these subapertures, the displacement is estimated by computing the 1-D cross-correlation of the backscattered signals acquired at two different times. The 3-D motion vector is then computed by a triangulation algorithm. This technique is experimentally validated in phantoms moving as fast as 40 mm s(-1), and combined with HIFU sequences. A real-time feedback correction of the HIFU beam is achieved by adjusting the delays of each channel. The sonications "locked on target" are interleaved with very short motion-estimation sequences. Finally, in vitro experiments of "locked on target" HIFU therapy are performed in fresh moving tissues. (E-mail: mathieu.pernot@loa.espci.fr) (C) 2004 World Federation for Ultrasound in Medicine Biology.
引用
收藏
页码:1239 / 1249
页数:11
相关论文
共 34 条
[1]  
ALLEN M, P ISTU 2002 SEATTL
[2]   TIME DOMAIN FORMULATION OF PULSE-DOPPLER ULTRASOUND AND BLOOD VELOCITY ESTIMATION BY CROSS-CORRELATION [J].
BONNEFOUS, O ;
PESQUE, P .
ULTRASONIC IMAGING, 1986, 8 (02) :73-85
[3]  
BRYAN PJ, 1984, J ULTRAS MED, V3, P317
[4]   A Doppler system for dynamic vector velocity maps [J].
Capineri, L ;
Scabia, M ;
Masotti, L .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (02) :237-248
[5]   COMPUTATION OF THE IMPULSE DIFFRACTION OF ANY OBSTACLE BY IMPULSE RAY MODELING - PREDICTION OF THE SIGNAL DISTORTIONS [J].
CASSEREAU, D ;
GUYOMAR, D .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1988, 84 (04) :1504-1516
[6]  
Chapelon J Y, 1999, Eur J Ultrasound, V9, P31, DOI 10.1016/S0929-8266(99)00005-1
[7]  
CHAPELON JY, 1992, EUR UROL, V22, P147
[8]  
CHAPELON JY, 1992, CANCER RES, V52, P6353
[9]   In vitro and in vivo ablation of porcine renal tissues using high-intensity focused ultrasound [J].
Damianou, C .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (09) :1321-1330
[10]   FOCAL SPACING AND NEAR-FIELD HEATING DURING PULSED HIGH-TEMPERATURE ULTRASOUND THERAPY [J].
DAMIANOU, C ;
HYNYNEN, K .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (09) :777-787