A frequency-based LCL filter design and control considerations for three-phase converters for solid-state transformer applications

被引:7
作者
Almaguer, J. [1 ]
Cardenas, V [1 ]
Aganza-Torres, A. [2 ]
Gonzalez, M. [4 ]
Alcala, J. [3 ]
机构
[1] Univ Autonoma San Luis Potosi, Ctr Invest & Estudios Posgrad, Fac Ingn, Av Dr Manuel Nava 8, San Luis Potosi 78290, Mexico
[2] Kassel Univ, Wilhelmshoher Allee 71, D-34121 Kassel, Germany
[3] Univ Colima, Fac Ingn Electromecan, Manzanillo, Colima, Mexico
[4] Univ Autonoma San Luis Potosi, Consejo Nacl Ciencia & Tecnol CONACYT, Fac Ingn, Ctr Invest & Estudios Posgrad, Av Dr Manuel Nava 8, San Luis Potosi 78290, Mexico
关键词
Solid-state transformer; Power control; LCL filter; Real-time simulation; GRID-CONNECTED INVERTERS; REAL-TIME SIMULATION; SYSTEM;
D O I
10.1007/s00202-019-00801-0
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a design methodology of a LCL filter for its application on the interconnection with the grid of a three-phase solid-state transformer, which is based on a three-stage configuration. The filter operates without damping resistors, and the design methodology proposed is based on the direct location of resonance frequencies, taking into consideration the effect of the grid impedance. The developed methodology can be applied to different power levels. In addition, control tuning considerations are proposed in order to avoid resonance points, evaluating the overall performance through the current total harmonic distortion in the point of common coupling. Furthermore, the used dq0 reference control frame achieves the objectives without the need to increase the number of sensors, neither the use of observers. The design methodology is validated by testing the operating system at 10 kW, 100 kW and 1 MW. For 1 MW, it is also implemented on a real-time simulator.
引用
收藏
页码:545 / 558
页数:14
相关论文
共 45 条
[11]  
Cho Y., 2016, IEEE MTT S INT MICR, P1, DOI DOI 10.1109/ECCE.2016.7855416
[12]  
Commission IE, 2011, 621092 IEC
[13]  
Commission IE, 2008, 6140021 IEC
[14]   Network integration of distributed power generation [J].
Dondi, P ;
Bayoumi, D ;
Haederli, C ;
Julian, D ;
Suter, M .
JOURNAL OF POWER SOURCES, 2002, 106 (1-2) :1-9
[15]  
Dong D, 2012, APPL POWER ELECT CO, P451, DOI 10.1109/APEC.2012.6165859
[16]   A NEW STATE-FEEDBACK BASED TRANSIENT CONTROL OF PWM AC TO DC VOLTAGE TYPE CONVERTERS [J].
DRAOU, A ;
SATO, Y ;
KATAOKA, T .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1995, 10 (06) :716-724
[17]  
Espinoza JR, 2000, IEEE IND APPLIC SOC, P2169, DOI 10.1109/IAS.2000.883126
[18]  
Gu HR, 2012, PROC IEEE INT SYMP, P1621, DOI 10.1109/ISIE.2012.6237333
[19]   Variable Structure Control in Natural Frame for Three-Phase Grid-Connected Inverters With LCL Filter [J].
Guzman, Ramon ;
Garcia de Vicuna, Luis ;
Castilla, Miguel ;
Miret, Jaume ;
Martin, Helena .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (05) :4512-4522
[20]  
Hill WA, 1998, IEEE IND APPLIC SOC, P1300, DOI 10.1109/IAS.1998.730312