Image quality and radiation exposure in 320-row temporal bone computed tomography

被引:19
作者
Bauknecht, H. C. [1 ]
Siebert, E. [1 ]
Dannenberg, A. [1 ]
Bohner, G. [1 ]
Jach, C. [1 ]
Diekmann, S. [1 ]
Scheurig, C. [2 ]
Klingebiel, R. [1 ]
机构
[1] Univ Med, Charite, Dept Neuroradiol, Berlin, Germany
[2] Univ Med, Charite, Dept Radiol, Berlin, Germany
关键词
cone beam computed tomography; tomography; X-ray computed; temporal bone; petrous bone; radiation dosage; HIGH-DENSITY STRUCTURES; CT SCANNER;
D O I
10.1259/dmfr/14139527
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim was to define image quality and radiation exposure in the recently introduced 320-row CT of the temporal bone (tb) in comparison to a 16-row tb CT. Methods: A cadaveric head phantom was used for repeated tb volume CT studies (80120 kV, 25-150 mAs), performed in a 320-row scanner (single rotation, 0.5 mm slice thickness, kernel FC 51) in comparison to 16-row helical CT using standard acquisition parameters (SAP) of 120 kV and 75 mAs (kernel FC 53). Qualitative image evaluation was performed by two radiologists using a 5-point visual analogue scale. Image noise (D(SD)) was determined by region of interest (ROI) based measurements in cadaveric as well as water phantom studies. Dosimetric measurements of the effective dose (ED) and organ dose (OD) of the lens were performed. Results: Image quality of 320-row tb CT was equivalent to 16-row CT for SAP scans, resulting in image noise levels (D(SD) 16-/320-row) of 109/237 and 206/446 for air and bone respectively. D(SD) differences were predominantly (>90%) attributable to the different kernels available for tb studies in 16- and 320-row CT. Radiation exposure for 16-/320-row SAP scans amounted to 0.36/0.30 mSv (ED) and 10.0/8.4 mGy (lens dose). Conclusion: 320-row volume acquisition in tb CT delivers equivalent image quality to 16-row CT while decreasing radiation exposure figures by one sixth. Image noise increase in 320-row CT is negligible with respect to image quality. Dentomaxillofacial Radiology (2010) 39, 199-206. doi: 10.1259/dmfr/14139527
引用
收藏
页码:199 / 206
页数:8
相关论文
共 18 条
[1]   Magnitude and effects of x-ray scatter in a 256-slice CT scanner [J].
Endo, Masahiro ;
Mori, Shinichiro ;
Tsunoo, Takanori ;
Miyazaki, Hiroaki .
MEDICAL PHYSICS, 2006, 33 (09) :3359-3368
[2]  
*EUR COMM EUR COMM, 1999, 16262 EC EUR EUR COM
[3]   Role of 3D CT in the evaluation of the temporal bone [J].
Fatterpekar, Girish M. ;
Doshi, Amish H. ;
Dugar, Mohit ;
Delman, Bradley N. ;
Naidich, Thomas P. ;
Som, Peter M. .
RADIOGRAPHICS, 2006, 26 :S117-U124
[4]   Multi-slice helical CT: Scan and reconstruction [J].
Hu, H .
MEDICAL PHYSICS, 1999, 26 (01) :5-18
[5]   High-resolution petrous bone imaging using multi-slice computerized tomography [J].
Klingebiel, R ;
Bauknecht, HC ;
Rogalla, P ;
Bockmühl, U ;
Kaschke, O ;
Werbs, M ;
Lehmann, R .
ACTA OTO-LARYNGOLOGICA, 2001, 121 (05) :632-636
[6]   Delineation of temporal bone anatomy:: feasibility of low-dose 64-row CT in regard to image quality [J].
Lutz, Juergen ;
Jaeger, Vanessa ;
Hempel, Martin John ;
Srivastav, Sudesh ;
Reiser, Maximilian ;
Jaeger, Lorenz .
EUROPEAN RADIOLOGY, 2007, 17 (10) :2638-2645
[7]   HIGH-RESOLUTION CT OF THE CHEST - RADIATION-DOSE [J].
MAYO, JR ;
JACKSON, SA ;
MULLER, NL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (03) :479-481
[8]   Effective doses in subjects undergoing computed tomography cardiac imaging with the 256-multislice CT scanner [J].
Mori, Shinichiro ;
Nishizawa, Kanae ;
Kondo, Chisato ;
Ohno, Mari ;
Akahane, Keiichi ;
Endo, Masahiro .
EUROPEAN JOURNAL OF RADIOLOGY, 2008, 65 (03) :442-448
[9]   Properties of the prototype 256-row (cone beam) CT scanner [J].
Mori, Shinichiro ;
Endo, Masahiro ;
Obata, Takayuki ;
Tsunoo, Takanori ;
Susumu, Kandatsu ;
Tanada, Shuji .
EUROPEAN RADIOLOGY, 2006, 16 (09) :2100-2108
[10]   Physical evaluation of the weighted Feldkamp algorithms applied to the 256-detector row CT scanner for volumetric Cine imaging [J].
Mori, Shinichiro ;
Endo, Masahiro ;
Kondo, Chisato ;
Tanada, Shuji .
ACADEMIC RADIOLOGY, 2006, 13 (06) :701-712