Differential Diagnosis Value of Shear-Wave Elastography for Superficial Enlarged Lymph Nodes

被引:7
作者
Sun, Yanjuan [1 ]
Wang, Wen [2 ]
Mi, Chengrong [1 ]
Zhang, Qian [2 ]
Zhang, Kun [3 ]
机构
[1] Ningxia Med Univ, Gen Hosp, Dept Ultrasound, 804 South Shengli St, Yinchuan, Peoples R China
[2] Ningxia Med Univ, Cardiovasc & Cerebrovascular Dis Hosp, Gen Hosp, Dept Ultrasound, Yinchuan, Peoples R China
[3] Tongji Univ, Sch Med, Shanghai Peoples Hosp 10, Dept Med Ultrasound,Cent Lab, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
ultrasound; shear-wave elastography; superficial enlarged lymph nodes; differential diagnosis; conventional ultrasonography; B-MODE; ULTRASOUND; BENIGN;
D O I
10.3389/fonc.2022.908085
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
ObjectivesTo evaluate the diagnostic efficiency and diagnostic threshold of conventional US and shear-wave elastography (SWE) in superficial enlarged lymph nodes (LNs). MethodsA total of 204 patients with superficial enlarged LNs were enrolled in this retrospective study aged 46.0 +/- 15.2 years from March 2020 to March 2021. LNs with a long axis larger than 0.7 cm were considered as superficial enlarged. Before the histological biopsy, LNs that were considered suspicious according to both conventional US and SWE were included, while LNs with no or unclear pathological results, or with no satisfactory SWE images, were excluded. The conventional and 2-D SWE examinations were performed with Aplio i800 and Acuson sequoia equipped with i18LX5 linear-array transducer (5-18 MHz) and 10L4 linear-array transducer (4-10 MHz), respectively. Both E Median and Vs Median parameters were investigated by two senior ultrasound physicians. The pathological results were performed as the gold standard. ResultsVariables including transverse axis size, lymphatic hilum, L/T ratio, echogenicity, and color Doppler pattern were considered significant. The mean E Median value in benign, metastatic LNs, and lymphoma were 28.26 +/- 8.87 kPa, 77.46 +/- 22.85 kPa, and 50.37 +/- 5.41 kPa (p <0.001), while Vs Median values were 3.02 +/- 0.50 m/s, 4.87 +/- 0.90 m/s, and 4.09 +/- 0.22 m/s, respectively (p < 0.001). The diagnostic performance indicated the high sensitivity, specificity, PPV, NPV, and overall accuracy of conventional US combined with SWE. The optimal cutoff values of E Median and Vs Median for predicting malignant LNs were 42.90 kPa and 3.73 m/s, respectively. As AUC value, sensitivity, specificity, accuracy, PPV, and NPV revealed, the indexes of E Median were 0.976, 0.927, 0.975, 0.946, 0.983, and 0.897, respectively, while Vs Median were 0.970, 0.927, 0.963, 0.941, 0.975, and 0.895, respectively (p <0.001). The ROC curves of both E Median (AUC=0.976) Vs Median (AUC=0.970) suggested the remarkable diagnostic efficiency in distinguishing benignity between suspected malignant LNs. ConclusionsAbove results indicated that conventional US together with 2-D SWE could elevate the diagnostic performance. Meanwhile, the parameters of 2-D SWE including E Median and Vs Median could effectively assess malignant LNs, which provide valuable differentiating information in superficial enlarged LNs.
引用
收藏
页数:9
相关论文
共 50 条
[41]   REGULARIZED TRACKING OF SHEAR-WAVE IN ULTRASOUND ELASTOGRAPHY [J].
Horeh, Mahmoud Derakhshan ;
Asif, Amir ;
Rivaz, Hassan .
2017 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2017, :6264-6268
[42]   Benefit of Shear-wave Elastography in the differential diagnosis of breast lesion: a diagnostic meta-analysis [J].
Luo, Jie ;
Cao, Yong ;
Nian, Weiqi ;
Zeng, Xiaohua ;
Zhang, Hui ;
Yue, Yeli ;
Yu, Feng .
MEDICAL ULTRASONOGRAPHY, 2018, 20 (01) :43-49
[43]   A nomogram constructed using intraoperative ex vivo shear-wave elastography precisely predicts metastasis of sentinel lymph nodes in breast cancer [J].
Bae, Soong June ;
Youk, Ji Hyun ;
Yoon, Chang Ik ;
Park, Soeun ;
Cha, Chi Hwan ;
Lee, Hak Woo ;
Ahn, Sung Gwe ;
Lee, Seung Ah ;
Son, Eun Ju ;
Jeong, Joon .
EUROPEAN RADIOLOGY, 2020, 30 (02) :789-797
[44]   Two-dimensional shear wave elastography for differential diagnosis between mastitis and breast malignancy [J].
Liu, Shui-Qing ;
Liu, Yan-Ping ;
Zhou, Bang-Guo ;
Deng, Xiao-Hong ;
Li, Xiao-Long ;
Xiang, Li-Hua ;
Ren, Wei-Wei ;
Xu, Hui-Xiong .
CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2018, 70 (03) :347-354
[45]   Ultrasound elastography: compression elastography and shear-wave elastography in the assessment of tendon injury [J].
Rui Prado-Costa ;
João Rebelo ;
João Monteiro-Barroso ;
Ana Sofia Preto .
Insights into Imaging, 2018, 9 :791-814
[46]   Ultrasound elastography: compression elastography and shear-wave elastography in the assessment of tendon injury [J].
Prado-Costa, Rui ;
Rebelo, Joao ;
Monteiro-Barroso, Joao ;
Preto, Ana Sofia .
INSIGHTS INTO IMAGING, 2018, 9 (05) :791-814
[47]   Agreement and accuracy of shear-wave techniques (point shear-wave elastography and 2D-shear-wave elastography) using transient elastography as reference [J].
Fernandes, Flavia ;
Piedade, Juliana ;
Freitas, Gabriela ;
Area, Philippe ;
Santos, Ricardo ;
Grinsztejn, Beatriz ;
Veloso, Valdilea ;
Pereira, Gustavo ;
Perazzo, Hugo .
EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2022, 34 (08) :873-881
[48]   Added value of shear wave elastography in the diagnosis of plantar fasciitis [J].
Morsy, Abdallah ;
Sakr, Hossam ;
Abdelwahab, Nadine ;
Wahby, Tarek .
EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2025, 56 (01)
[49]   VALUE OF SHEAR WAVE ELASTOGRAPHY IN THE DIAGNOSIS OF GOUTY AND NON-GOUTY ARTHRITIS [J].
Tang, Yuanjiao ;
Yan, Feng ;
Yang, Yujia ;
Xiang, Xi ;
Wang, Liyun ;
Zhang, Lingyan ;
Qiu, Li .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (05) :884-892
[50]   Assessment of thyroid gland elasticity with shear-wave elastography in Hashimoto's thyroiditis patients [J].
Kara, Turgay ;
Ates, Fatih ;
Durmaz, Mehmet Sedat ;
Akyurek, Nesibe ;
Durmaz, Funda Gokgoz ;
Ozbakir, Bora ;
Ozturk, Mehmet .
JOURNAL OF ULTRASOUND, 2020, 23 (04) :543-551