Lens Equivalent dose of Staff During Endoscopic Retrograde Cholangiopancreatography: Dose Comparison Using Two Types of Dosemeters

被引:9
作者
Morishima, Yoshiaki [1 ,2 ]
Chida, Koichi [2 ]
Meguro, Takayoshi [3 ]
Hirota, Morihisa [3 ]
Chiba, Hiroo [1 ]
Fukuda, Hiroshi [4 ]
机构
[1] Tohoku Med & Pharmaceut Univ Hosp, Dept Radiol Technol, Miyagino Ku, 1-12-1 Fukumuro, Sendai, Miyagi 9838512, Japan
[2] Tohoku Univ, Dept Radiol Technol, Sch Hlth Sci, Sendai, Miyagi 9808575, Japan
[3] Tohoku Med & Pharmaceut Univ Hosp, Gastroenterol Ctr, Sendai, Miyagi 9838512, Japan
[4] Tohoku Med & Pharmaceut Univ, Dept Radiol, Fac Med, Sendai, Miyagi 9838356, Japan
关键词
ERCP; lens equivalent dose; DOSIRIS (TM); radiation protectionglass badge; RADIATION PROTECTION; INTERVENTIONAL RADIOLOGY; EYE LENS; MEDICAL STAFF; PHYSICIANS; SAFETY; PERFORMANCE; CARDIOLOGY; EXPOSURE; SYSTEM;
D O I
10.1093/rpd/ncac160
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study aimed to compare the lens equivalent dose (LED) measured during endoscopic retrograde cholangiopancreatography (ERCP) using DOSIRIS (TM) as a dedicated dosemeter to that measured using glass badges to determine if glass badges can be alternative tools for LED measurement. LEDs for physicians during ERCP were measured using the DOSIRIS (TM) [3-mm dose equivalent] worn on the outer edge of the eyes and personal dosemeters (glass badges) [0.07-mm dose equivalent] worn on the right and left sides of the neck. The cumulated doses over 6 months for the left eye using DOSIRIS (TM) were 9.5 and 11.8 mSv for physicians A and B, whereas doses measured using glass badges were 7.5 and 11.6 mSv, respectively. The LEDs of the physicians at the left eye and left neck side showed almost similar values and were significantly correlated (r = 0.95; p < 0.01). For an accurate LED measurement during ERCP, using a dosemeter such as DOSIRIS (TM) is recommended, although similar LED estimation values were reported using glass badges on the left neck side.
引用
收藏
页码:1368 / 1376
页数:9
相关论文
共 54 条
  • [1] Optimisation of Radiation Exposure to Gastroenterologists and Patients during Therapeutic ERCP
    Alzimami, Khalid
    Sulieman, Abdelmoneim
    Paroutoglou, Georgios
    Potamianos, Spiros
    Vlychou, Marianna
    Theodorou, Kiki
    [J]. GASTROENTEROLOGY RESEARCH AND PRACTICE, 2013, 2013
  • [2] [Anonymous], 2011, Statement on tissue reactions
  • [3] Effect of Radiation Monitoring Method and Formula Differences on Estimated Physician Dose during Percutaneous Coronary Intervention
    Chida, K.
    Morishima, Y.
    Masuyama, H.
    Chiba, H.
    Katahira, Y.
    Inaba, Y.
    Mori, I.
    Maruoka, S.
    Takahashi, S.
    Kohzuki, M.
    Zuguchi, M.
    [J]. ACTA RADIOLOGICA, 2009, 50 (02) : 170 - 173
  • [4] CHIDA K, 2022, RADIOL PHYS TECHNOL
  • [5] Occupational Dose in Interventional Radiology Procedures
    Chida, Koichi
    Kaga, Yuji
    Haga, Yoshihiro
    Kataoka, Nozomi
    Kumasaka, Eriko
    Meguro, Taiichiro
    Zuguchi, Masayuki
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (01) : 138 - 141
  • [6] Physician-received scatter radiation with angiography systems used for interventional radiology: comparison among many X-ray systems
    Chida, Koichi
    Morishima, Yoshiaki
    Inaba, Youhei
    Taura, Masaaki
    Ebata, Ayako
    Takeda, Ken
    Shimura, Hirotaka
    Zuguchi, Masayuki
    [J]. RADIATION PROTECTION DOSIMETRY, 2012, 149 (04) : 410 - 416
  • [7] Clarifying and Visualizing Sources of Staff-Received Scattered Radiation in Interventional Procedures
    Chida, Koichi
    Takahashi, Takeshi
    Ito, Daisuke
    Shimura, Hirotaka
    Takeda, Ken
    Zuguchi, Masayuki
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (05) : W900 - W903
  • [8] Radiation Dose and Radiation Protection for Patients and Physicians During Interventional Procedure
    Chida, Koichi
    Kato, Mamoru
    Kagaya, Yutaka
    Zuguchi, Masayuki
    Saito, Haruo
    Ishibashi, Tadashi
    Takahashi, Shoki
    Yamada, Shogo
    Takai, Yoshihiro
    [J]. JOURNAL OF RADIATION RESEARCH, 2010, 51 (02) : 97 - 105
  • [9] Evaluating the performance of a MOSFET dosimeter at diagnostic X-ray energies for interventional radiology
    Chida K.
    Inaba Y.
    Masuyama H.
    Yanagawa I.
    Mori I.
    Saito H.
    Maruoka S.
    Zuguchi M.
    [J]. Radiological Physics and Technology, 2009, 2 (1) : 58 - 61
  • [10] Radiation protection effect of mobile shield barrier for the medical personnel during endoscopic retrograde cholangiopancreatography: a quasi-experimental prospective study
    Chung, Kwang Hyun
    Park, Young Sook
    Ahn, Sang Bong
    Son, Byoung Kwan
    [J]. BMJ OPEN, 2019, 9 (03):