Comparative Study Between Polydioxanone Unidirectional Barbed Suture and Absorbable Polyglactin Running Suture in Partial Nephrectomy

被引:0
作者
Pirvut, Mircea Valentin [1 ]
Grigore, Nicolae [1 ,2 ]
Mihai, Ionela [1 ]
Priporeanu, Alexandru Tiberiu [3 ]
Racheriu, Mihaela [1 ,2 ]
Cretu, Dan [1 ,2 ]
Teodoru, Adrian [1 ,2 ]
Sabau, Dan [1 ,2 ]
Mitariu, Loredana [1 ,2 ]
Ranga, Remus [1 ,2 ]
Manea, Marinela Minodora [4 ,5 ]
Hasegan, Adrian [1 ,2 ]
机构
[1] Acad Emergency Cty Hosp, 2-4 Corneliu Coposu Str, Sibiu 550245, Romania
[2] Lucian Blaga Univ, Fac Med, 2A Lucian Blaga Str, Sibiu 550169, Romania
[3] Clin Inst Fundeni, 258 Fundeni, Bucharest 022328, Romania
[4] UMF Iuliu Hatieganu, Dept Med Psychol, 8 Victor Babes Str, Cluj Napoca 400012, Romania
[5] Cty Emergency Clin Hosp Cluj Napoca, Psychiat Clin 3, 3-5 Clinicilor Str, Cluj Napoca 400000, Romania
关键词
polydioxanone; polyglactin; suture materials; partial nephrectomy;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Combining technological development in the laparoscopic field alongside the increase of surgeon's experience in partial nephrectomy, have extended the indications of laparoscopic nephron sparing surgery to more complicated cases, increasing the role of suture materials in obtaining a good collecting system closure and hemostasis, with short warm ischemia time and low postoperative complications rate. Suturing materials are continuously developed combining new and unique designs with novel synthetic materials in order to fulfill surgeon's exigence.
引用
收藏
页码:82 / 84
页数:3
相关论文
共 12 条
[1]   Indications and the Role of Laparoscopic Partial Nephrectomy [J].
Bladou, Franck .
EUROPEAN UROLOGY SUPPLEMENTS, 2010, 9 (03) :454-458
[2]   The Use of Self-Retaining Barbed Suture for Inner Layer Renorrhaphy Significantly Reduces Warm Ischemia Time in Laparoscopic Partial Nephrectomy: Outcomes of a Matched-Pair Analysis [J].
Erdem, Selcuk ;
Tefik, Tzevat ;
Mammadov, Anar ;
Ural, Feyyaz ;
Oktar, Tayfun ;
Issever, Halim ;
Nane, Ismet ;
Sanli, Oner .
JOURNAL OF ENDOUROLOGY, 2013, 27 (04) :452-458
[3]  
Greenberg James A, 2009, Rev Obstet Gynecol, V2, P146
[4]  
Grigoras RI, 2016, MATER PLAST, V53, P501
[5]  
Grigore N, 2017, MATER PLAST, V54, P295
[6]  
Kadirkamanathan SS, 1996, J AM COLL SURGEONS, V182, P46
[7]  
KAYGISIZ O., 2017, COMP 2 DIFFERENT SUL, V43
[8]   The clinical application of the sliding loop technique for renorrhaphy during robot-assisted laparoscopic partial nephrectomy: Surgical technique and outcomes [J].
Kim, Hyung Suk ;
Lee, Young Ju ;
Ku, Ja Hyeon ;
Kwak, Cheol ;
Kim, Hyeon Hoe ;
Jeong, Chang Wook .
KOREAN JOURNAL OF UROLOGY, 2015, 56 (11) :762-768
[9]   How reliable is intracorporeal laparoscopic knot tying? [J].
Lopez, Pedro-Jose ;
Veness, John ;
Wojcik, Andrew ;
Curry, Joe .
JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES, 2006, 16 (04) :428-432
[10]  
Niculescu M, 2016, MATER PLAST, V53, P642