Capacitances versus Losses in Distribution Transformers Design

被引:0
作者
Picanco, A. F. [1 ]
Poderoso, F. C. [1 ]
Nascimento, T. A. [1 ]
机构
[1] Fed Inst Educ Sci & Technol Bahia, Salvador, BA, Brazil
来源
2014 IEEE INTERNATIONAL ENERGY CONFERENCE (ENERGYCON 2014) | 2014年
关键词
Capacitance; Design; Distribution Transformer; Losses;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents the relation between the losses and capacitances in three-phase distribution transformers. The motivation stems from the search of projects with reduction of losses and economic viability as the variation of the constructive parameters, which varies the losses consequently, changes of capacitances. This paper aims to obtain knowledge about how the changes in the design whose goal is loss reduction, change the capacitances and initial distribution of voltage on the winding, parameters that may change the behavior of transformers especially when under disturbances of high levels frequency.
引用
收藏
页码:234 / 241
页数:8
相关论文
共 8 条
  • [1] [Anonymous], 1999, 5440 ABNT NBR
  • [2] EUROPEAN COPPER INSTITUTE, 1999, SCOP EN SAV EU US EN
  • [3] Greenwood A., 1991, ELECT TRANSIENTS POW, V2nd
  • [4] Kulkarni S. V., 2013, Transformer Engineering -Design and Practice, V2nd
  • [5] Picanco A.F., 2008, 6 MED C EXH POW GEN
  • [6] Picanco A.F., 2009, THESIS U FEDERAL ITA
  • [7] Putman T.H., 1963, IEEE T POWER APPARAT, V82, P1018
  • [8] U.S. DEPARTMENT OF ENERGY, 2007, DISTR TRANSF FIN RUL