Development of Goaf Gas Drainage and Inertisation Strategies in 1.0-km- and 3.0-km-Long Panels

被引:14
作者
Balusu, Rao [1 ]
Belle, Bharath [2 ,3 ]
Tanguturi, Krishna [1 ]
机构
[1] CSIRO Energy, 1 Technol Court, Kenmore 4068, Australia
[2] Anglo Amer Coal, Brisbane, Qld, Australia
[3] Univ Pretoria, Pretoria, South Africa
关键词
Goaf gas drainage; Maingate (MG) goaf holes; Tailgate (TG) goaf holes; Inertisation; Sponcom;
D O I
10.1007/s42461-019-0071-9
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
A collaborative research project is undertaken by Anglo American Coal and CSIRO to develop appropriate strategies for gas and spontaneous combustion management of longer panels. Extensive computational fluid dynamics (CFD) modelling studies have been conducted and calibrated using operational longwall goaf gas data to obtain a fundamental understanding of goaf gas flow patterns in longwall panels of 1.0-km and 3.0-km lengths and a detailed investigation of the effect of various mining and operational parameters on goaf gas flow patterns. The modelling studies have also been used to investigate the performance of various gas drainage and proactive inertisation strategies during various stages of longwall panel extraction. Simulation results indicated that apart from tailgate (TG) side goaf holes, gas drainage from maingate (MG) goaf holes and the mid panel start-up goaf holes would be useful for flat seam field conditions. Operation of 8-10 goaf holes is recommended for field site conditions with high goaf gas emissions of 6000 L/s. The modelling results indicated that the traditional inert gas flow rate of 500 L/s currently used in some mines would be insufficient to achieve effective goaf inertisation in long panels. Results indicate that 3.0-km-long panels would require 1500 L/s of inert gas and there is a need for multi-point inert gas injection strategy for effective goaf inertisation. In this paper, details and results of modelling investigations and recommended strategies for gas and spontaneous combustion management in 1.0-km- and 3.0-km-long panels are presented.
引用
收藏
页码:1127 / 1136
页数:10
相关论文
共 15 条
[1]  
Balusu R., 2004, ACARP report C10017
[2]  
Balusu R, 2002, 9 US MIN VENT S
[3]  
Belle B, 2015, AUSTR MIN VENT C SYD
[4]  
BRUNNER DJ, 1995, PROCEEDINGS OF THE 7TH US MINE VENTILATION SYMPOSIUM, P479
[5]  
Collecutt G., 2009, 7 INT C CFD MINERALS, P1
[6]  
EDWARDS RN, 1995, ULTRA-WIDEBAND, SHORT-PULSE ELECTROMAGNETICS 2, P41
[7]  
Fletcher CAJ, 1995, AUSTRALAS I MIN MET, V95, P361
[8]   Modeling of gas flow and temperature fields in underground coal fires [J].
Huang, JJ ;
Bruining, J ;
Wolf, KHAA .
FIRE SAFETY JOURNAL, 2001, 36 (05) :477-489
[9]   Prevention of gob ignitions and explosions in longwall mining using dynamic seals [J].
Juergen, Brune F. ;
Saqib, Saki A. .
INTERNATIONAL JOURNAL OF MINING SCIENCE AND TECHNOLOGY, 2017, 27 (06) :999-1003
[10]  
Moloney K, 1998, COMP APPL MIN IND IN, P721