Indoor air quality in an air-conditioned building in new Delhi and its relationship to ambient air quality

被引:4
|
作者
Prasad, RK
Uma, R
Kansal, A
Gupta, S
Kumar, P
Saksena, S
机构
[1] East West Ctr, Honolulu, HI 96848 USA
[2] AsianPaints, New Delhi, India
[3] Tata Energy Res Inst, New Delhi 110003, India
[4] GGS Indraprastha Univ, New Delhi, India
关键词
indoor air pollution; outdoor air pollution; ventilation; noise; air handling unit;
D O I
10.1159/0000068234
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In an urban city like Delhi, vehicular exhaust is a major source of air pollution in addition to industrial activities emitting uncontrolled air pollutants. This contaminated air is sucked into buildings by air handling units contaminating the indoor air. In addition, indoor air is further contaminated by sources used for cooking, space heating devices, various chemicals and so on. The present paper analyses the indoor and outdoor air quality in a commercial building. The functioning of the air handling unit was also studied in the context of indoor air quality. Pollutants such as asbestos, carbon monoxide, formaldehyde, lead, oxides of nitrogen, ozone, respirable suspended particulates, sulphur dioxide and suspended particulate matter and gases such as oxygen and carbon dioxide were monitored. Copyright (C) 2003 S. Karger AG, Basel.
引用
收藏
页码:334 / 339
页数:6
相关论文
共 50 条
  • [11] Ventilation characteristics of an air-conditioned office building in Singapore
    Sekhar, SC
    Tham, KW
    Cheong, D
    BUILDING AND ENVIRONMENT, 2002, 37 (03) : 241 - 255
  • [12] Indoor Air Quality Monitoring Improving Air Quality Perception
    Herberger, Simone
    Ulmer, Heiko
    CLEAN-SOIL AIR WATER, 2012, 40 (06) : 578 - 585
  • [13] Indoor air quality and academic performance
    Stafford, Tess M.
    JOURNAL OF ENVIRONMENTAL ECONOMICS AND MANAGEMENT, 2015, 70 : 34 - 50
  • [14] Industrialization, indoor and ambient air quality, and elderly mental health
    Ao, Chon-Kit
    Dong, Yilin
    Kuo, Pei-Fen
    CHINA ECONOMIC REVIEW, 2021, 69
  • [15] Vehicle air leakage ventilation and its effect on cabin indoor air quality
    Chang, Tong-Bou
    Sheu, Jer-Jia
    Huang, Jhong-Wei
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2017, 231 (06) : 1226 - 1234
  • [16] Ventilation and Indoor Air Quality
    Kumar, Ashok
    Moreno-Rangel, Alejandro
    Khan, M. Amirul, I
    Piasecki, Michal
    ATMOSPHERE, 2022, 13 (10)
  • [17] MODELING OF INDOOR AIR QUALITY
    Teodosiu, Catalin
    Ilie, Viorel
    Teodosiu, Raluca
    ENERGY AND CLEAN TECHNOLOGIES, 2015, : 969 - 976
  • [18] Indoor air quality in schools
    Cartieaux, E.
    Rzepka, M. -A.
    Cuny, D.
    ARCHIVES DE PEDIATRIE, 2011, 18 (07): : 789 - 796
  • [19] Relationship among Concentrations of Indoor Air Contaminants, Their Sources, and Different Mitigation Strategies on Indoor Air Quality
    Widder, Sarah H.
    Haselbach, Liv
    SUSTAINABILITY, 2017, 9 (07)
  • [20] Influence of Gender on Thermal, Air-Movement, Humidity and Air-Quality Perception in Mixed-Mode and Fully Air-Conditioned Offices
    Maykot, Jessica Kuntz
    de Oliveira, Candi Citadini
    Ghisi, Enedir
    Rupp, Ricardo Forgiarini