Indoor air quality in an air-conditioned building in new Delhi and its relationship to ambient air quality

被引:4
|
作者
Prasad, RK
Uma, R
Kansal, A
Gupta, S
Kumar, P
Saksena, S
机构
[1] East West Ctr, Honolulu, HI 96848 USA
[2] AsianPaints, New Delhi, India
[3] Tata Energy Res Inst, New Delhi 110003, India
[4] GGS Indraprastha Univ, New Delhi, India
关键词
indoor air pollution; outdoor air pollution; ventilation; noise; air handling unit;
D O I
10.1159/0000068234
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In an urban city like Delhi, vehicular exhaust is a major source of air pollution in addition to industrial activities emitting uncontrolled air pollutants. This contaminated air is sucked into buildings by air handling units contaminating the indoor air. In addition, indoor air is further contaminated by sources used for cooking, space heating devices, various chemicals and so on. The present paper analyses the indoor and outdoor air quality in a commercial building. The functioning of the air handling unit was also studied in the context of indoor air quality. Pollutants such as asbestos, carbon monoxide, formaldehyde, lead, oxides of nitrogen, ozone, respirable suspended particulates, sulphur dioxide and suspended particulate matter and gases such as oxygen and carbon dioxide were monitored. Copyright (C) 2003 S. Karger AG, Basel.
引用
收藏
页码:334 / 339
页数:6
相关论文
共 50 条
  • [1] Indoor Air Quality Related to Occupancy at an Air-conditioned Public Building
    Ponsoni, Karina
    Goncalves Raddi, Maria Stella
    BRAZILIAN ARCHIVES OF BIOLOGY AND TECHNOLOGY, 2010, 53 (01) : 99 - 103
  • [2] An energy impact assessment of indoor air quality acceptance for air-conditioned offices
    Wong, L. T.
    Mui, K. W.
    Shi, K. L.
    Hui, P. S.
    ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (10) : 2815 - 2819
  • [3] Indoor air quality comparison of two air-conditioned zones served by the same air-handling unit
    Tham, KW
    Sekhar, SC
    Cheong, D
    BUILDING AND ENVIRONMENT, 2002, 37 (10) : 947 - 960
  • [4] Assessment of indoor air quality in air-conditioned small business units with no mechanical ventilation
    Sankaran, Gayatri
    Tan, Sze Tat
    Shen, Joanna
    Gutierrez, Ramona
    Ng, Lee Ching
    Sim, Shuzhen
    ATMOSPHERIC ENVIRONMENT, 2023, 299
  • [5] Indoor Environmental Quality Benchmarks for Air-conditioned Offices in the Subtropics
    Mui, K. W.
    Wong, L. T.
    Hui, P. S.
    INDOOR AND BUILT ENVIRONMENT, 2009, 18 (02) : 123 - 129
  • [6] Comparison of Indoor Air Quality for Air-Conditioned and Naturally Ventilated Office Spaces in Urban Area
    Jain, Supreme
    Garg, Divyam
    Goel, Anubha
    INDOOR ENVIRONMENTAL QUALITY, ACIEQ, 2020, 60 : 1 - 8
  • [7] Effects of Partition on Thermal Comfort, Indoor Air Quality, Energy Consumption, and Perception in Air-Conditioned Buildings
    Aryal, Pradip
    Leephakpreeda, Thananchai
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2016, 138 (05):
  • [8] Radon and its decay products in an air-conditioned auditorium in correlation with indoor air parameters
    Polednik, Bernard
    Kozak, Krzysztof
    Mazur, Jadwiga
    Dudzinska, Marzenna
    Grzadziel, Dominik
    INDOOR AND BUILT ENVIRONMENT, 2017, 26 (05) : 621 - 630
  • [9] Sick building syndrome - A case study in a multistory centrally air-conditioned building in the Delhi City
    Gupta, Sanjeev
    Khare, Mukesh
    Goyal, Radha
    BUILDING AND ENVIRONMENT, 2007, 42 (08) : 2797 - 2809
  • [10] Indoor and outdoor particles in an air-conditioned building during and after the 2013 haze in Singapore
    Chen, Ailu
    Cao, Qingliang
    Zhou, Jin
    Yang, Bin
    Chang, Victor W. -C.
    Nazaroff, William W.
    BUILDING AND ENVIRONMENT, 2016, 99 : 73 - 81