The use of mass spectrometry in electrochemical measurements - The DEMS technique.

被引:27
|
作者
de Souza, JPI [1 ]
Queiroz, SL [1 ]
Nart, FC [1 ]
机构
[1] Univ Sao Paulo, Inst Quim Sao Carlos, BR-13560970 Sao Carlos, SP, Brazil
来源
QUIMICA NOVA | 2000年 / 23卷 / 03期
关键词
electrochemical reactions; mass spectrometry; DEMS;
D O I
10.1590/S0100-40422000000300016
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The combination of cyclic voltammetry and on line mass spectrometry, called differential electrochemical mass spectrometry (DEMS), is already a well established method far on line identification and quantitative detection of the products and intermediates of electrochemical reactions. This article aims to show the principles of the method and how this technique have been used to study electrochemical problems such the electrocatalytic oxidation of organic molecules, as methanol and ethanol, at noble metal electrodes.
引用
收藏
页码:384 / 391
页数:8
相关论文
共 50 条
  • [1] RESIN BEAD MASS SPECTROMETRY AS A SAFEGUARDS VERIFICATION TECHNIQUE.
    Walker, R.L.
    Smith, D.H.
    Carter, J.A.
    Donohue, D.L.
    Deron, S.
    Asakuba, Y.
    Kagami, K.
    Irinouchi, S.
    Masui, J.
    Nuclear materials management, 1981, 10 (03): : 43 - 49
  • [2] Carbon nanocoils as catalysts support for methanol electrooxidation: A Differential Electrochemical Mass Spectrometry (DEMS) study
    Celorrio, V.
    Calvillo, L.
    Moliner, R.
    Pastor, E.
    Lazaro, M. J.
    JOURNAL OF POWER SOURCES, 2013, 239 : 72 - 80
  • [3] STUDY OF THE DEVELOPMENT OF MASS TRANSPORT PATHS VIA AN ELECTROCHEMICAL FLOW VISUALIZATION TECHNIQUE.
    Quraishi, M.S.
    Fahidy, T.Z.
    Canadian Journal of Chemical Engineering, 1980, 60 (01): : 100 - 104
  • [4] MULTIPATH PROPAGATION MEASUREMENTS BY DOPPLER TECHNIQUE.
    Form, P.
    Springer, R.
    1600, 979. Available from NTIS, Springfield, Va
  • [5] The use of gelatin in microscopical technique.
    Johnson, W
    LANCET, 1913, 2 : 1062 - 1062
  • [6] A chemical ionization mass spectrometry technique for airborne measurements of ammonia
    Nowak, J. B.
    Neuman, J. A.
    Kozai, K.
    Huey, L. G.
    Tanner, D. J.
    Holloway, J. S.
    Ryerson, T. B.
    Frost, G. J.
    McKeen, S. A.
    Fehsenfeld, F. C.
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2007, 112 (D10)
  • [7] THE USE OF MASS-SPECTROMETRY AS A PROCESS TECHNIQUE - AN EVALUATION
    SCRIVENS, JH
    VACUUM, 1982, 32 (03) : 169 - 174
  • [8] SHELL-AND-TUBE HEAT EXCHANGER DATA PRODUCED BY AN ELECTROCHEMICAL MASS TRANSFER MODELLING TECHNIQUE.
    Macbeth, Robert V.
    1978,
  • [9] USE OF A MICROCOMPUTER FOR STREAMING POTENTIAL TECHNIQUE.
    Menard, H.
    Dubreuil, B.
    Grise, M.
    Giguere, J.
    Chemical, biomedical, and environmental instrumentation, 1980, 10 (04): : 371 - 376
  • [10] STATE ANALYSIS OF Ca IN STEEL BY ELECTROCHEMICAL SEPARATION TECHNIQUE.
    Yoshida, Yoshio
    Funahashi, Yoshiko
    Kamino, Yoshikazu
    Tetsu-To-Hagane/Journal of the Iron and Steel Institute of Japan, 1982, 68 (01): : 162 - 171